Acceleration Sensor - Sony PDW-HD1500 Maintenance Manual

Professional disc recorder
Hide thumbs Also See for PDW-HD1500:
Table of Contents

Advertisement

4-7-4. ACCELERATION SENSOR

This menu allows you to check the acceleration sensor on
the optical drive.
n
Be sure to place the unit horizontally when checking the
sensor.
The check may be failed if the optical drive is incorrectly
placed.
Menu hierarchy:
[M6 : DRIVE]
→ [D0 : DRIVE MAINTENANCE]
→ [CHECK]
→ [DEVICE]
→ [ACCELERATION SENSOR]
1. A confirmation screen appears waiting for entry of the
[SET] button.
ACCELERATION SENSOR
CHECK START?
OK:
SET KEY
EXIT: MENU KEY
2. Press the [SET] button.
A confirmation screen appears.
ACCELERATION SENSOR
PLACE DRIVE
HORIZONTALLY.
ARE YOU SURE?
OK:
SET KEY
EXIT: MENU KEY
3. Check that the unit is placed horizontally, and press
the [SET] button.
When the optical drive is detected as horizontal, the
following screen appears.
ACCELERATION SENSOR
CHECKING...OK
SENSOR POSTURE:OK
AGAIN: SET KEY
EXIT: MENU KEY
4-16
If failed:
The following screen appears.
Check optical drive posture and sensor installation.
n
CHECKING:
Disconnection check result
SENSOR POSTURE: SENSOR POSTURE check result
If the disconnection check results in an error, the SENSOR
POSTURE check is not carried out.
ACCELERATION SENSOR
CHECKING...OK
SENSOR POSTURE:TILTING!
AGAIN: SET KEY
EXIT: MENU KEY
PDW-HD1500/V1 (E)

Hide quick links:

Advertisement

Table of Contents
loading