Canon CLC1000 Service Manual page 375

Color laser copier
Table of Contents

Advertisement

Sorter
Code
There is no clock signal from the
l
clock sensor (P15) of the feeding
motor for 250 ms or more.
Low-speed feeding motor (MlO;
l
rotation failure)
Locking cam (buffer path unit;
l
home position not detected)
Push bar motor (M7; rotation fail-
l
. Reference wall motor (M6; rota-
Multi guide motor (MS; rotation
l
Bin paper sensor 1 (53, S4; auto
l
adjustment fault)
Bin paper sensor 2 (S6, S7; auto
l
adjustment)
Guide bar motor (M8 rotation
l
f a i l u r e )
Stapler unit drive motor (M4;
l
rotation failure)
Stapler unit shift motor (M3; rota-
l
Cause
CANON CLCI 990 REV.1 MAY 1997 PRINTED IN JAPAN (IMPRIME AU JAPON)
Description
. There is no clock signal from the clock sen-
sor (P15) of the feeding motor fopr 250 ms
or more.
There is no clock signal from the clock sen-
l
sor (P123) of the feeding motor for 250 ms
or more.
The home position is not detected within a
l
specific time' after the Copy Start key has
been pressed.
*Varies depending on copier.
* The operation does not end within 2000 ms
after the motor drive signal has been gener-
ated.
* The operation does not end within 2000ms
after the motor drive signal has been gener-
ated.
The operation does not end within 2000 ms
l
after the motor drive signal has been gener-
ated.
. Auto adjustment of the bin paper sensor 1
(S3, S4) cannot be executed; or, an error
has occurred in the auto adjustment value.
Auto adjustment of the bin paper sensor
l
(S6, S7) cannot be executed; or, an error
has occurred in the auto adjustment value.
The operation does not end within a specif-
l
ic time after the motor drive signal has
been generated: 5000 ms if front retrieval,
and 2000 ms otherwise.
The operation does not end within 2000 ms
l
after the motor drive signal has been gener-
There is no clock signal from the clock sen-
l
sor (Pl8) of the motor for 250 ms or more.
The input signal from the shifting home
l
position sensor (P19) for 1000 ms or more.
* The operation does not end within 5000 ms
after the motor drive signal has been gener-
ated.

Advertisement

Table of Contents
loading

Table of Contents