Canon CLC1000 Service Manual page 287

Color laser copier
Table of Contents

Advertisement

11. HV-TR (transfer high-voltage output adjustment by condition)
ADJUST
Item
Indicates the machine internal temperature measured
B O D Y "C
by the environment sensor.
BODY %
Indicates the machine internal humidity measured by
the environment sensor.
BODY g
Indicates the machine internal humidity absolute value
(g) measured by the environment sensor.
Adjusts the transfer high-voltage output.
Indicates the machine internal humidity absolute value
ZONE-A/B/C
(g) in the three ranges of A through C.
1:
Note
The setting of this item will return to the default value when the PCB is replaced or the RAM is
cleared, requiring input once again. Be sure to record any new setting you have made on the service
label.
3-260
<M>
HV-TR-Y
xxx
x x x %
BODY
xxx
Description
CANON CLCIOOO REV.1 MAY 1997 PRINTED IN JAPAN (IMPRIME
ZONE A
ZONE B
s e e 3/4
Z O N E
C 18.Og to ---g s e e 414
Remarks
Same as the reading
under 'DISPLAY' +
'ANALOG'.
Settings: -5 to +5
Unit: 1 .O uA
Standard: 0
AU JAPON)