FUNC
Entering Backup Data
I
If you have executed 'RAM-CLR' for the DC controller PCB, use this screen to enter the data recorded
on the label shown in Figure 3-l 102.
Item
Use it to enter the value of the SALT signal.
Y/M/C/K
REF-S-Y/M/C/K
Use it to enter the value of the SALT reference signal.
Use it to enter the value of the signal representing the
Y/M/C/K
intensity of light reflected by the photosensitive drum.
Use it to enter the value of the gain for the SALT sig-
nal.
PT-OFST-K
Use it to enter the adjustment value of the density
pattern for SALT.
Use it to enter the adjustment value for pick-up timing
adjustment (P-UP-TMG).