Canon CLC1000 Service Manual page 294

Color laser copier
Table of Contents

Advertisement

Item
Indicates the machine internal temperature "measured
B O D Y "C
by the environment sensor.
Indicates the machine internal humidity measured by
BODY %
the environment sensor.
Indicates the machine internal humidity absolute value
BODY g
(g) measured by the environment sensor.
Indicates the zone in which the setting shown is effec-
tive.
EL-N1
Effective in plain paper mode and, in addition, when
copying on a one-sided copy or on the 1st side of a
two-sided copy.
Effective in plain paper mode and, in addition, when
EL-N2
copying on the 2nd side of a two-sided copy.
EL-OHP
Effective in OHP mode.
Effective during image position correction control.
EL-#
Effective in thick paper mode and, in addition, copyin
EL-T1
on a one-sided copy or on the 1 st side of a two-side 8
CODV.
Effective in thick paper mode and, in addition, copying
EL-T2
on the 2nd side of a two-sided copy.
Effective in ultra thick paper mode and, in addition,
EL-UT1
Effective in ultra thick paper mode and, in addition,
EL-UT2
when copying on the 2nd side of a two-sided copy.
Effective in special paper 1 mode and, in addition,
when copying on a one-sided copy or on the 1st side
of a two-sided copy.
Effective in special paper 1 mode and, in addition,
when copying on the 2nd side of a two-sided copy.
Effective in special paper 2 mode and, in addition,
EL-S2-1
EL-S2-2
Effective in special paper 2 mode and, in addition,
when copying on the 2nd side of a two-sided copy.
Effective in special paper 3 mode and, in addition,
EL-S3-1
when copying on a one-sided copy or on the 1st side
of a two-sided copy.
In special paper 3 mode and, in addition, when copy-
EL-S3-2
ing on the 2nd side of a two-sided copy.
The setting of this item will return to the default value when the PCB is replaced or tne
requiring input once again. Be sure to record any new setting you have made on the service label.
HV-EL
Description
CANON CLClOOO REV.1 MAY lBB7 PRINTED IN JAPAN (IMPAIME AU
Remarks
Same as the reading
under 'DISPLAY' +
'ANALOG'.
Settings: -5 to +l
Unit: 0.5 kV
Standard: 0
H A M I8 clearea,
3 - 2 6 7