Ground Connections; Input Power Connections; Input Fuse And Supply Wire Considerations; Input Voltage Reconnect Procedure - Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual

Lincoln electric power supply user manual
Table of Contents

Advertisement

A-4
CAUTION
Failure to follow these instructions can cause immedi-
ate failure of components within the welder.

GROUND CONNECTIONS

The frame of the welder must be grounded.
A ground terminal marked with the symbol
is located inside the reconnect/input
access door for this purpose. See your
local and national electrical codes for proper ground-
ing methods. See Figure A.2 for the location of the
reconnect/input access door and related connection
diagram.

INPUT POWER CONNECTIONS

Connect L1, L2, L3 according to the Input Supply
Connection Diagram decal located on the reconnect/-
input access door. See Figure A.2.
INPUT FUSE AND SUPPLY WIRE
CONSIDERATIONS
Refer to the Technical Specifications at the beginning
of this Installation section for recommended fuse and
FIGURE A.2 - CONNECTION DIAGRAM ON RECONNECT/INPUT ACCESS DOOR
NOTE: Turn main input power to
mthe machine OFF before perform-
ing reconnect procedure. Failure to
do so will result in damage to the
machine.
DO NOT switch the re-
connect bar with machine power
ON.
Also called "inverse time" or "thermal/magnetic" circuit breakers. These breakers have a delay in tripping action that decreases as the mag-
nitude of the current increases.
INSTALLATION
wire sizes.
mended super lag fuses or delay type circuit breakers.
Choose an input and grounding wire size according to
local or national electrical codes. Using fuses or cir-
cuit breakers smaller than recommended may result in
"nuisance" shut-offs from welder inrush currents, even
if the machine is not being used at high currents.
INPUT VOLTAGE RECONNECT
PROCEDURE
Welders are shipped connected for the highest input
voltage listed on the rating plate. To change this con-
nection for a different input voltage, refer to reconnect
instructions in Figure A.2 and proceed according to
the steps that follow for the appropriate voltage.
POWER WAVE 450
Fuse the input circuit with the recom-
A-4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450

Table of Contents