Serial Loop Wiring Harness Test - Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual

Lincoln electric power supply user manual
Table of Contents

Advertisement

F-107
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if there are any short circuits or other problems in the serial loop
wiring between the power board, the control board, the display board, wire feeder 1
amphenol (P83) and wire feeder 2 amphenol (P82).
MATERIALS NEEDED
Volt/Ohmmeter (Multimeter)
5/16" Nut driver
3/8" Nut driver
Serial Loop Wiring Diagram Figure – F.38
This procedure takes approximately 30 minutes to perform.
TROUBLESHOOTING & REPAIR

SERIAL LOOP WIRING HARNESS TEST

WARNING
POWER WAVE 450
F-107

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450

Table of Contents