FLEXTEC™ 450&650 CE
OPERATOR'S MANUAL
ENGLISH
THE LINCOLN ELECTRIC COMPANY
22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA
www.lincolnelectric.eu

Advertisement

Table of Contents
loading

Summary of Contents for Lincoln Electric FLEXTEC 450 CE

  • Page 1 IM2059 04/2014 REV01 FLEXTEC™ 450&650 CE OPERATOR’S MANUAL ENGLISH THE LINCOLN ELECTRIC COMPANY 22801 St. Clair Ave., Cleveland Ohio 44117-1199 USA www.lincolnelectric.eu...
  • Page 2: The Lincoln Electric Company

    THE LINCOLN ELECTRIC COMPANY EC DECLARATION OF CONFORMITY FOR FLEXTEC™450 CE Manufacturer and technical documentation holder: The Lincoln Electric Company Address: 22801 St. Clair Ave. Cleveland Ohio 44117-1199 USA EC Company: Lincoln Electric Europe S.L. Address: c/o Balmes, 89 - 8...
  • Page 3 THE LINCOLN ELECTRIC COMPANY EC DECLARATION OF CONFORMITY FOR FLEXTEC™650 CE Manufacturer and technical documentation holder: The Lincoln Electric Company Address: 22801 St. Clair Ave. Cleveland Ohio 44117-1199 USA EC Company: Lincoln Electric Europe S.L. Address: c/o Balmes, 89 - 8...
  • Page 4: Table Of Contents

    12/05 THANKS! For having chosen the QUALITY of the Lincoln Electric products.  Please Examine Package and Equipment for Damage. Claims for material damaged in shipment must be notified immediately to the dealer.  For future reference record in the table below your equipment identification information. Model Name, Code &...
  • Page 5: Technical Specifications

    Technical Specifications FLEXTEC™ 650 POWER SOURCE – INPUT VOLTAGE AND CURRENT Power Input Model Duty Cycle Input Voltage ±10% Idle Power (W) Factor@ Rated Amperes Input 60% rating 61/50/40 230 MAX (Fan On) K3060-2 380/460/575/3/50/60 100% rating 57/47/38 100 MAX. (Fan Off) RATED OUTPUT Process Duty Cycle...
  • Page 6 FLEXTEC™ 450 POWER SOURCE – INPUT VOLTAGE AND CURRENT Power Input Model Duty Cycle Input Voltage ±10% Idle Power Factor@ Rated Amperes Input 60% rating 37/35/34 380/400/415/3/50/60 K3065-1 72 W Max. (fan on) 100% rating 29/28/27 RATED OUTPUT Process Duty Cycle Volts at rated Amperes Amperes 36.5V...
  • Page 7: Electromagnetic Compatibility (Emc)

    Lincoln Electric. The Class A equipment is not intended for use in residential locations where the electrical power is provided by the public low-voltage supply system.
  • Page 8: Safety

    Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this equipment. Read and understand the following explanations of the warning symbols. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation.
  • Page 9: Installation And Operator Instructions

    CYLINDER MAY EXPLODE IF DAMAGED: Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. Always keep cylinders in an upright position securely chained to a fixed support. Do not move or transport gas cylinders with the protection cap removed.
  • Page 10: Input Connection

    Input Connection Example: 40% Duty Cycle: Use a three-phase supply line. For Flextec™ 650 (see figure #1): a 45 mm diameter access hole for the input supply is located on the case back. Remove the reconnect access panel located on the case back and connect W, V, U and ground according to the Input Supply Connection Diagram Welding for 4 minutes.
  • Page 11: Welding Cable Connections

    Figure #1: Flextec™650 A: POWER SUPPLY ACCESS HOLE:  Route input power cable through this hole.  Strain relief required. See your local and National Electrical codes for proper strain relief. B: RECONNECT TERMINAL BLOCK:  Reconnects auxiliary transformer for the proper input voltage. C: POWER SUPPLY TERMINAL BLOCK: ...
  • Page 12: Control Cable Connections

    Control Cable Connections General guidelines Genuine Lincoln control cables should be used at all times (except where noted otherwise). Generally, it is recommended that the total length not exceed 100 feet (30.5 m). The use of non-standard cables, especially in lengths greater than 25 feet, can lead to communication problems (system shutdowns), poor motor acceleration (poor arc starting), and low wire driving force (wire...
  • Page 13 VRD™ (VOLTAGE REDUCTION DEVICE) The VRD™ feature provides additional safety in the CC- Stick mode. The VRD™ reduces the OCV (Open Circuit Voltage) at the welding output terminals while not welding to less than 35VDC. The machine is shipped with VRD™ “enabled”. The VRD™...
  • Page 14: Product Description

    Product Description Case Front Control Desciptions for The FLEXTEC™ 650 is a multi-process CC/CV DC Flextec™ 650 inverter and is rated for 650 amps, 44 volts at a 100% (see Figure #4) duty cycle. The FLEXTEC™ 450 is a multi-process Power Switch: Controls input power to the Flextec CC/CV DC inverter and is rated for 450 amps, 38 volts at 650.
  • Page 15 Case Front Control Desciptions for Case Back Control Desciptions for Flextec™ 450 Flextec™ 650 (see Figure #5) Power Switch (see Figure #6) Voltage Display Meter Amperage Display Meter Input Power Cord Access Hole Thermal LED Access Panel – Allows access dor connecting input Output Control Dial power and configuring the machine.
  • Page 16: Common Welding Procedures

    Common Welding Procedures Voltage Display Meter • Prior to CV operation (current flow), the meter The FLEXTEC™ 450&650 are a multi-process inverter displays desired preset voltage value (+/- .5V only welder. The Weld Process Selector Switch is used to for Flextec™650). set the desired weld mode.
  • Page 17 GTAW Basic Modes of Operation This weld mode is a constant current (CC) mode featuring continuous control from 10 – 815 amps (for SMAW flextec™ 650) and 10 – 500 amps (for Flextec™ 450). It is intended for the GTAW tig welding processes. This weld mode is a constant current (CC) mode featuring continuous control from 15 –...
  • Page 18 Hot Start For Flextec™ 650– Rotate from the “0” position to the “10” position to provide more energy Arc Control – The Arc Control regulates pinch effect. At during the start of a weld. the minimum setting (-10), minimizes pinch and results Hot Start For Flextec™...
  • Page 19 After welding, the meter recommended to contact the nearest technical service holds the actual amperage value for 5 seconds. Output center or Lincoln Electric. Maintenance or repairs adjustment while in the "hold" period results in the "prior performed by unauthorized service centers or personnel to operation"...
  • Page 20: Weee

    12/05 Part List reading instructions  Do not use this part list for a machine if its code number is not listed. Contact the Lincoln Electric Service Department for any code number not listed.  Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine.