SAFETY PRECAUTIONS

Read this entire installation section before you start
installation.
WARNING
ELECTRIC SHOCK can kill.
• Only qualified personnel should per-
form this installation.
• Turn the input power OFF at the
disconnect switch or fuse box before working on
this equipment. Turn off the input power to any
other equipment connected to the welding system
at the disconnect switch or fuse box before work-
ing on the equipment.
• Do not touch electrically hot parts.
• Always connect the POWER WAVE® S350
grounding lug to a proper safety (Earth) ground.
-------------------------------------------------------------
SELECT SUITABLE LOCATION
The POWER WAVE® S350 will operate in harsh envi-
ronments. Even so, it is important that simple preven-
tative measures are followed in order to assure long life
and reliable operation.
• The machine must be located where there is free cir-
culation of clean air such that air movement in the
back, out the sides and bottom will not be restricted.
• Dirt and dust that can be drawn into the machine
should be kept to a minimum. The use of air filters
on the air intake is not recommended because nor-
mal air flow may be restricted. Failure to observe
these precautions can result in excessive operating
temperatures and nuisance shutdown.
• Keep machine dry. Shelter from rain and snow. Do
not place on wet ground or in puddles.
• Do not mount the POWER WAVE® S350 over com-
bustible surfaces. Where there is a combustible sur-
face directly under stationary or fixed electrical
equipment, that surface shall be covered with a steel
plate at least .060" (1.6mm) thick, which shall extend
not less than 5.90" (150mm) beyond the equipment
on all sides.
INSTALLATION
LIFTING
Both handles should be used when lifting POWER WAVE® S350.
When using a crane or overhead device a lifting strap should be
connected to both handles. Do not attempt to lift the POWER
WAVE® S350 with accessories attached to it.
FALLING
EQUIPMENT can
cause injury.
-------------------------------------------------------------

STACKING

The POWER WAVE® S350 cannot be stacked.

TILTING

Place the machine directly on a secure, level surface or on a rec-
ommended undercarriage. The machine may topple over if this
procedure is not followed.

INPUT AND GROUND CONNECTIONS

Only a qualified electrician should connect the POWER WAVE®
S350. Installation should be made in accordance with the ap-
propriate National Electrical Code, all local codes and the infor-
mation in this manual.

MACHINE GROUNDING

The frame of the welder must be grounded. A ground terminal
marked with a ground symbol is located next to the input power
connection block.
See your local and national electrical codes for proper grounding
methods.

HIGH FREQUENCY PROTECTION

The EMC classification of the POWER WAVE® S350 is Industrial,
Scientific and Medical (ISM) group 2, class A. The POWER
WAVE® S350 is for industrial use only. (See print L10093 for fur-
ther details).
Locate the POWER WAVE® S350 away from radio controlled
machinery. The normal operation of the POWER WAVE® S350
may adversely affect the operation of RF controlled equipment,
which may result in bodily injury or damage to the equipment.
POWER WAVE ® S350
WARNING
• Lift only with equipment of ade-
quate lifting capacity.
• Be sure machine is stable when
lifting.
• Do not operate machine while
suspended when lifting.
A-4