Installation; Technical Specifications - Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual

Lincoln electric power supply user manual
Table of Contents

Advertisement

A-2
TECHNICAL SPECIFICATIONS - POWER WAVE 450
Input Voltages:
Input Currents
@ 500A/40 VDC
@ 450A/38 VDC
Duty Cycle
60% Duty Cycle
100% Duty Cycle
Constant Open
Circuit Voltage
75 Volts
Pulse
Current Range
5-750 Amps
RECOMMENDED INPUT WIRE AND FUSE SIZES
Input
Duty
Voltage/
Cycle
Freqency
200/50-60
60%
230/50-60
60%
400/50-60
60%
460/50-60
60%
575/50-60
60%
200/50-60
100%
230/50-60
100%
400/50-60
100%
460/50-60
100%
575/50-60
100%
Height
905 mm
35.6 in.
OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE
0° to 40°C

INSTALLATION

INPUT -THREE PHASE ONLY
200
87
75
RATED OUTPUT
Amps
500
450
Continuous
Current Range
5-540 Amps
Pulse
Pulse and Background
Voltage Range
5-55 Volts
100 Microsec - 3.3 Sec
Type 75°C
Input Ampere
Copper Wire in
Rating on
Nameplate
AWG[IEC]
Sizes (MM
87
76
44
38
32
75
65
38
32
28
PHYSICAL DIMENSION
Width
515 mm
20.3 in.
POWER WAVE 450
230
400
76
44
65
38
Volts at Rated Amperes
GMAW 50-540 Amps
FCAW 40-540 Amps
STICK 30-540 Amps
Time Range
Type 75°C
Ground Wire in
Conduit
Conduit
AWG[IEC]
2
)
Sizes (MM
4 (25)
8 (10)
4 (25)
8 (10)
8 (10)
10 (6)
8 (10)
10 (6)
8 (10)
10 (6)
4 (25)
8 (10)
4 (25)
8 (10)
8 (10)
10 (6)
8 (10)
10 (6)
8 (10)
10 (6)
Depth
1010 mm
39.8 in.
-50° to 85°C
A-2
460
575
38
32
32
28
40 VDC
38 VDC
Process
Current Ranges
Pulse
Frequency
0.15 - 1000 Hz
Type 75°C
(Super Lag)
or Breaker
Size (Amps)
2
)
120
100
50
50
50
100
100
50
50
40
Weight
137.9 kg
303.5 lbs.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450