Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual page 240

Lincoln electric power supply user manual
Table of Contents

Advertisement

F-180
DISPLAY BOARD REMOVAL AND REPLACEMENT (continued)
NOTE:
Before changing or disturbing the dis-
play board follow the procedure outlined under
QUICK VOLTAGE CALIBRATION (Fig. F.54)
in this section.
PROCEDURE
1. Remove main input supply power to the
machine.
2. With the 3/8" nut driver, remove the 4
screws that hold the handle to the machine.
3. Remove the rubber gasket (cover seal) from
the lift bail.
4. With the 5/16" nut driver, remove the sheet
metal screws from the case top.
5. With the 5/16" nut driver, remove the
screws holding the right and left case sides.
Remove the case sides by lifting up and
out.
6. Perform
the
Procedure described earlier in this section
of the manual.
TROUBLESHOOTING & REPAIR
FIGURE F.68 - DISPLAY BOARD REMOVAL
1. MOLEX PLUG HEADERS (8)
2. KEY PAD RIBBON CONNECTOR
3. LCD DISPLAY WINDOW
4. LCD CONNECTOR
5. MOUNTING PIN HOLE
Capacitor
Discharge
POWER WAVE 450
WARNING
Before continuing with the
test procedure, perform the
capacitor discharge proce-
dure to avoid electric shock.
CAUTION
Be sure to follow the recommended static-free
methods for handling printed circuit boards.
Failure to do so can result in permanent dam-
age to the equipment.
7. After you have completed the capacitor dis-
charge procedure for all four switch boards,
carefully remove the eight molex plugs from
the lower portion of the display board.
F-180

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450

Table of Contents