F-85
Service and repair should be performed by only Lincoln Electric factory trained personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician or
machine operator and will invalidate your factory warranty. For your safety and to avoid elec-
trical shock, please observe all safety notes and precautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to perform the
test/repairs safely, contact the Lincoln Electric Service Department for electrical trou-
bleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).
TEST DESCRIPTION
This test will determine if any leads connected to the reconnect switch are damaged.
MATERIALS NEEDED
Volt/Ohmmeter (Multimeter)
5/16" Nut driver
3/8" Nut driver
Input and Reconnect Wiring Diagram – Figure F.29
This procedure takes approximately 40 minutes to perform.
TROUBLESHOOTING & REPAIR
RECONNECT SWITCH TEST 2
WARNING
POWER WAVE 450
F-85