Output Connections; Work And Electrode Cable Connections; Size; Routing - Lincoln Electric INVERTEC POWER WAVE 450 SVM112-B Service Manual

Lincoln electric power supply user manual
Table of Contents

Advertisement

A-5
1
3
1 WORK TERMINAL
2 ELECTRODE TERMINAL
3 REMOTE CONTROL AMPHENOL RECEPTACLE
To operate at 200-208 VAC:
1. Open the reconnect/input access door.
2. Move the input voltage switch to Voltage = 200-
208V position.
3. Move "A" lead to the 200-208V terminal.
To operate at 220-230 VAC:
1. Open the reconnect/input access door.
2. Move the input voltage switch to voltage = 220-
230V position.
3. Move "A" lead to the 220-230V terminal.
To operate at 380-415 VAC:
1. Open the reconnect/input access door.
2. Move the input voltage switch to Voltage = 380-
415V position.
3. Move "A" lead to the 380-415 VAC terminal.
To operate at 440-460 VAC: No setup required. The
machine is factory-connected to operate at 440 volts.
To verify, do the following:
1. Open the reconnect/input access door.
2. Check that the input voltage switch is set to
Voltage = 440-460V position.
3. Check that the "A" lead is at the 440-460V.
INSTALLATION
FIGURE A.3 – FRONTPANEL/BACK PANEL
2

OUTPUT CONNECTIONS

See Figure A.3 for the location of the work terminal,
electrode terminal, remote control amphenol recepta-
cle, water cooler fittings and wire feeder connections.
WORK AND ELECTRODE CABLE
CONNECTIONS

SIZE

Use the largest welding (electrode and ground) cables
possible — at least 70mm
if the output current does not require it. When pulsing,
the pulse current often exceeds 650 amps with the
Power Wave 450. Voltage drops can become exces-
sive if undersized welding cables are used.

ROUTING

To avoid interference problems with other equipment
and to achieve the best possible operation, route all
cables directly. Avoid excessive lengths, bundle the
electrode and ground cables together where practical,
and do not coil excess cable.

WATER COOLER CONNECTIONS

The water cooler fittings are a quick-connect type.
Refer to the Accessories section of this manual for
water cooler operation and antifreeze mixtures.

WIRE FEEDER CONNECTIONS

Refer to the Accessories section for Wire Feeder Con-
nections.
Refer to Setup overlay in Operation section for Wire
Feeder Configuration.
POWER WAVE 450
6
5
(IN)
(OUT)
4 WATER COOLING FITTINGS (ON BACK PANEL)
5 WIRE FEEDER CONNECTIONS (ON BACK PANEL)
6 ELECTRODE TERMINAL
2
A-5
4
(#2/0) copper wire — even

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Invertec power wave 450

Table of Contents