4. Check all joints from equipment shutoff
valve to control valve (see Figure 16 or
17, page 16). Apply a noncorrosive leak
detection fluid to all joints. Bubbles form-
ing show a leak.
5. Correct all leaks at once.
INSTALLATION FOR DECORATIVE TRIM
1. Identify left, right and top decorative trim
pieces (see Figure 18).
2. Slide slots in 3 trim pieces over screws on
the fireplace (see Figure 19).
Top Trim Piece
Right Trim Piece
Left Trim Piece
Figure 18 - Decorative Trim
200069-01A
INSTALLATION
6. Light heater (see Lighting Instructions on
page 20). Check all other internal joints
for leaks.
7. Turn off heater (see To Turn Off Gas Ap-
pliance, page 21).
Screw
Figure 19 - Installing Decorative Trim