Reading Parameters

Label Gone Timeout

This feature sets the time after the last label segment is seen before the reader prepares for a new
label. The timeout can be set within a range of 10 milliseconds to 2,550 milliseconds (2.55
seconds) in 10ms increments. Label Gone Timeout does not apply to scan modes that require a
trigger pull for each label that is read
Follow these instructions to set this feature:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with lead-
3. Go to
4. Scan the barcode: SELECT LABEL GONE TIMEOUT SETTING.
5. Scan the appropriate three alpha-numeric characters from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 40. Timeout Setting Examples
STEP
ACTION
1
Desired Setting
Divide by 10 (and pad with
2
leading zeroes)
3
4
Scan Three Characters From
5
Appendix D, Keypad
6
252
ing zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc.
page 67
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
Keypad
representing the duration which was determined in the steps above. You will hear
a two-beep indication after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
50ms
005
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT LABEL GONE TIMEOUT SETTING
'0' , '0' and '5'
Scan ENTER/EXIT PROGRAMMING MODE
Table 40
for some examples of how to set this feature.
EXAMPLES
150ms
1800ms (1.8 sec.)
015
'0' , '1' and '5'
'1' , '8' and '0'
Appendix D,
2550ms (2.55 sec.)
180
255
''2' , '5' and '5'
WLS9600