Wasp WLS9600 Product Reference Manual page 245

1d laser scanner usb
Hide thumbs Also See for WLS9600:
Table of Contents

Advertisement

ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host
following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15
seconds) in 200ms increments. A selection of 0 disables the timeout.
To set this value:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with
3. Go to
4. Scan the barcode: SELECT ACK NAK TIMEOUT VALUE SETTING.
5. Scan the appropriate two digits from the keypad in
6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming
This completes the procedure. See
Table 31. ACK NAK Timeout Value Setting Examples
STEP
ACTION
1
Desired Setting
2
Divide by 200
3
4
Scan Two Characters From
5
Appendix D, Keypad
6
Product Reference Guide
leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc.
page 29
and scan the ENTER/EXIT PROGRAMMING MODE barcode to enter
Programming Mode.
the duration which was determined in the steps above. You will hear a two-beep indica-
tion after the last character.
If you make a mistake before the last character, scan the CANCEL barcode to
abort and not save the entry string. You can then start again at the begin-
ning.
Mode.
200ms
01
Scan ENTER/EXIT PROGRAMMING MODE
Scan SELECT ACK NAK TIMEOUT VALUE SETTING
'0' and '1'
Scan ENTER/EXIT PROGRAMMING MODE
Appendix D,
Table 31
for some examples of how to set this feature.
EXAMPLES
1,000ms (1 sec.)
5200ms (5.2 sec.)
05
'0' and '5'
RS-232 Parameters
Keypad, that represent
15,000ms (15 sec.)
26
75
'2' and '6'
'7' and '5'
235

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents