The two-way parallel interface is compatible with the IEEE1284 compatibility mode and nibble
mode. Contact your dealer for details.
Table of Connection Signals for Each Mode
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19~30
31
32
33
34
35
36
Note:
1) The prefix "n" on the signal name refers to low active signals. If the host does not
have any one of the signal lines listed above, two-way communication fails.
2) For interfacing, signal lines should always use twisted pair cables with the return
sides connected to the signal ground level.
(1 9 )
(1 )

12. Parallel Interface

Direction
In
In/Out
In/Out
In/Out
In/Out
In/Out
In/Out
In/Out
In/Out
Out
Out
Out
Out
OUT
In
Out
In
In
(3 6 )
(1 8 )
Parallel interface connector (printer side)
Compatibility Mode
Signal Name
nStrobe
Data0
Data1
Data2
Data3
Data4
Data5
Data6
Data7
nAck
Busy
PError
Select
Signal GND
Frame GND
+5 V
Twisted Pair Return
nInit
nFault
External GND
Compulsion status
nSelectIn
This connector mates with an
Amphenol 57-30360 connector
– 53 –
Nibble Mode
Signal Name
Host Clock
Data0
Data1
Data2
Data3
Data4
Data5
Data6
Data7
PtrClk
PtrBusy/Data3,7
AckDataReq/Data2,6
Xflag/Data1,5
HostBusy
Signal GND
Flame GND
+5 V
Twisted Pair Return
nInit
nDataAvail/Data0,4
1284Active