B-1. Parallel Interface Type

ON
OFF
No. 1
2 3 4 5 6 7 8
DIP-SW1
Switch 1-1
OFF
The factory settings of DIP switch are all on.
The functions of switches 1-2 through 1-8 will change according to the command
emulation that has been set using switche 1-1.
(1) Star mode
Switch
1-1
Command emulation
1-2
Should not be changed (Should be set to on)
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
Automatic status back function
1-8
Should not be changed (Should be set to on)
(2) ESC/POS mode
Switch
1-1
Command emulation
1-2
Graphic adjustment
1-3
Should not be changed (Should be set to on)
1-4
Sensor adjustment
1-5
Pin #31 (INIT) reset signal
1-6
Handshaking conditions
(conditions for BUSY)
1-7
Automatic status back function
1-8
Should not be changed (Should be set to on)
DIP-SW 1
ON
Function
Function
ON
OFF
No. 1
2 3 4
DIP-SW2
Command emulation
Star Mode
ESC/POS Mode
ON
Always ON
Invalid
Valid
Offline or receive
buffer full
Invalid
ON
Always OFF
203 DPI
Invalid
Valid
Offline or receive
buffer full
Invalid
– 85 –
OFF
Valid
Invalid
Receive buffer full
Valid
OFF
180 DPI
Valid
Invalid
Receive buffer full
Valid