7.3.4

Trigger Delay

This function delays trigger signal against trigger input signal.
The step is 1µs and the range for setting is 16bit, from 0 to 65,535µs.
7.4.

Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)

This is used for applications which do not require triggering. In this mode, the video signal for the
auto-iris lens is available.
For the video timing, refer to chapter 6.3.
The frame rate of full pixels readout is 54.7 fps for 1X2–2YE output format.
Primary settings to use this mode
Trigger control
Trigger Mode: OFF
Table - 17
1X- 2YE output
Minimum frame line
Note 1) Only for EL-2800M-CXP
Note 2) Readout mode in trigger overlap is not available.
7.5.

Timed mode (EPS)

This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
The frame rate of full pixels readout is 54.7 fps for 1X2–2YE output format.
Primary settings to use this mode
Exposure mode: Timed
Trigger mode: ON
Frame Start : ON
Table - 18
1X–2YE output
Minimum frame line
Note 1) EL-2800M only
Note 2) This table shows in case of Trigger option being set to Readout. If Trigger
option is set to OFF, this period is longer than the figures in this table.
EL-2800M-CXP / EL-2800C-CXP
Minimum interval of the image(1X–2YE, 8-bit)
FULL
744
Minimum interval of the trigger pulse(1X–2YE, 8-bit)
FULL
2/3 AOI
745
2/3 AOI
1/2 AOI
564
474
1/2 AOI
1/4 AOI
565
475
- 43 -
1/4 AOI
1/8 AOI
339
272
1/8 AOI
Binning
(Note1)
340
273
1/2V
Binning
(Note1)
375
1/2V
376