Electronic Shutter - JAI CM-030PMCL-RH User Manual

1/3” progressive scan monochrome remote head camera
Table of Contents

Advertisement

6.1.2.

Electronic Shutter

CM-0303PMCL-RH allows selecting shutter speed in two ways; preset shutter (10 fixed steps)
and programmable exposure (in 511 line period, LVAL, increments).
Preset Shutter
The following shutter speeds can be selected by command SH=0 through SH=9.
OFF (1/120), 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/8000, 1/10000, 1/15000, 1/30000
seconds
Programmable Exposure (PE)
The exposure time can be programmed in 16.24µs (LVAL period) increments. The range is
from 2 LVAL to 511 LVAL.
Minimum exposure time 2L
16.24 µs x 2(L) = 32.48 µs
In binning mode:
Minimum Exposure time 2L
20.069 µs x 2(L) = 40.138 µs
Preset shutter time for each output mode
The preset shutter value is converted to the programmable value (PE) inside the camera.
Accordingly, there is a slight difference between the preset shutter value and the actual
exposure time. Please refer the following table.
Preset
Shutter
Value[s]
Off(1/120)
1/250
1/500
1/1000
1/2000
1/4000
1/8000
1/10000
1/15000
1/30000
CM-030PMCL-RH
Exposure
lines
[Line]
FULL (µs)
511
246
123
62
31
15
8
6
4
2
Maximum exposure time 511L
16.24 µs x 511 (L) ≈ 8.299 ms
Maximum exposure time 257L
20.069 µs x 257 (L) ≈ 5.158 ms
Actual exposure
VBinning(µs)
8299
5158
3995
4937
1998
2468
1007
1244
503
622
244
301
130
161
97.4
120
65
80.3
32.5
40.1
10

Advertisement

Table of Contents
loading