Lighting Instructions - Valor 1500IN (NG) Installation & Owner's Manual

L1 series
Table of Contents

Advertisement

OWNER'S
INFORMATION
WARNING: If you do not follow these instructions exactly, a fi re or explosion may result
causing property damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand, remote control, or wall switch. Follow these instructions
exactly. To save gas, turn the pilot off when not using the appliance for a prolonged period of time.
B. BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the fl oor because
some gases are heavier than air and will settle on the fl oor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fi re department.
C. Use only your hand to push in or turn the control knobs. Never use tools. If the knobs will not push in or turn by
hand, don't try to repair them; call a qualifi ed service technician. Force or attempted repair may result in a fi re or
explosion.
D. Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician to
inspect the appliance and to replace any part of the control system and any gas control, which has been under water.
1. STOP! Read the safety information above.
2. TO CLEAR ANY GAS, turn main valve off by pressing OFF (red dot) button on remote
handset (1).
• Wait fi ve (5) minutes to clear out any gas, then smell for gas, including near the fl oor. If you
smell gas, STOP! Follow "B" in the safety information above on this label. If you don't smell
gas, go to the next step.
3. AUTOMATIC IGNITION: MAN-knob (2) in ON position. Ensure Flame Adjustment
knob (3) is set to lowest setting () (Fig. 1). Locate the pilot (Fig. 3.) inside of
fi rebox at left hand side.
• On the remote control handset, press the OFF button (red dot) and large fl ame
button () simultaneously; a short acoustic signal confi rms the start has begun.
• Further short acoustic signals indicate the ignition process is in progress.
• When the pilot is lit, the Flame Adjustment knob (3) will automatically rotate to
the highest setting.
• Press the small fl ame button () on the remote control handset to reduce the
fl ame height.
4. MANUAL IGNITION: MAN-knob (2) in MAN position (Fig. 2). With the window
off, locate the pilot (Fig. 3) inside of fi rebox at left hand side.
• Set Flame Adjustment knob (3) to the lowest setting ().
• Push down the metallic core (4) with a pen or similar instrument; this will establish
the pilot gas fl ow.
• Light gas at the pilot (5) with a match.
• Continue holding down metal core (4) for about 10 seconds; after release, pilot
should remain lit.
If the pilot will not stay lit after several tries, turn the gas control knob (3) to OFF () and call your local
service technician or gas supplier.
• Reinstall the window and set the MAN-knob (2) to ON; turn Flame Adjustment knob (3) up () or down ()
manually or use the fl ame buttons ()() buttons on the remote control handset to adjust the fl ame height.
AUTOMATIC SHUT-OFF (using the remote control handset):
• Press and hold the small fl ame button () on the remote control handset to shut-off the main burner gas fl ow.
• Press OFF button (red dot) on remote handset to shut-off the appliance, including pilot fl ame.
16

Lighting Instructions

FOR YOUR SAFETY, READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
TO TURN OFF GAS TO APPLIANCE
1
OFF
Fig 1
5
Spark
Pilot
Fig 3
Fig 2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1500ip (lpg)L1 series

Table of Contents