INSTALLATION MANUAL
1500NMUK / 1500PMUK Module Upgrade Kits
for Valor models 1500 and 1600 Linears
Use with Valor L1 1500, 1600 I or J Heater Models ONLY, to convert to 1500K or 1600K
Kit Contents
• 1500K Burner rail assembly 4007084AH and hard-
ware
• 1500K Burner module plate assembly (no receiver)
» 4008269 for natural gas
» 4008270 for propane
• Conversion label 4008271
Tools Required
• Wrenches, to disconnect gas line
• Phillips (+) screwdriver, to remove burner module
Specifi cations
Models
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure (in w.c.)
Maximum Supply Pressure (in w.c.)
Main Burner Injector Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
* This appliance is certifi ed for use from 0–4500 feet. For
altitudes above 4500 feet, see local codes.
4008257-01
©2020, Miles Industries Ltd.
L1 Series
1500KN
1500KP
1600KN
1600KN
Natural
Propane
0-4,500 feet*
30,000
30,000
19,000
21,000
3.5"
9.0"
5"
11"
10"
14"
DMS#36
DMS#51
51
30
220
160
 WARNING
This upgrade kit shall be installed by a
qualifi ed service agency in accordance
with the manufacturer's instructions and
all applicable codes and requirements
of the authority having jurisdiction. If
the information in these instructions is
not followed exactly, a fi re, explosion
or production of carbon monoxide
may result causing property damage,
personal injury or loss of life. The
qualifi ed service agency is responsible
for the proper installation of this kit. The
installation is not proper and complete
until the operation of the converted
appliance is checked as specifi ed in the
manufacturer's instructions supplied with
the kit.
Use this manual in conjunction with the
installation manual supplied with the
appliance.

Advertisement

loading

Summary of Contents for Valor L1 Series

  • Page 1 L1 Series 1500NMUK / 1500PMUK Module Upgrade Kits for Valor models 1500 and 1600 Linears Use with Valor L1 1500, 1600 I or J Heater Models ONLY, to convert to 1500K or 1600K Kit Contents  WARNING • 1500K Burner rail assembly 4007084AH and hard-...
  • Page 2 Prepare Appliance 2. Remove the left and right defl ectors refi tting each screw to plug the holes left opened in the fi rebox You must access the burner and the module plate to bottom. The defl ectors are no longer necessary. replace them.
  • Page 3: Test For Leaks

    Test Manifold Pressure 10. Secure the module plate with 10 screws. 1. Fit a manometer to the manifold pressure test tap on the valve using 1/4” ID tubing —see fi gure below. Manifold Pressure Valve Inlet Test Tap Pressure Top view Loosen screws inside inlets to check (tighten Install New Burner...
  • Page 4 2. Adjust the aeration lever left and right as required to achieve optimum fl ame picture. See Installation Manual for details. Open Closed Designed and Manufactured by / for Miles Industries Ltd. 190 – 2255 Dollarton Highway, North Vancouver, B.C., CANADA V7H 3B1 Tel. 604-984-3496 Fax 604-984-0246 www.valorfi replaces.com...
  • Page 5: Guide D'installation

    Série L1 Trousse de brûleur K 1500NMUK / 1500PMUK pour foyers Valor 1500 et 1600 Linears Conversion au brûleur 1500K pour les foyers Valor L1 1500 et 1600 I ou J SEULEMENT Contenu  AVERTISSEMENT • Brûleur 1500K 4007084AH et quincaillerie •...
  • Page 6: Préparez L'appareil

    Préparez l’appareil 2. Enlevez les défl ecteurs droit et gauche du fond de la boîte de foyer. Réutilisez les vis pour boucher les Vous devez accéder au brûleur et à la plaque du brûleur trous de fi xation des défl ecteurs. Les défl ecteurs ne pour les remplacer.
  • Page 7 Vérifi ez la pression d’admission 10. Fixez la plaque du brûleur avec 10 vis. 1. Fixez un manomètre à la connexion de vérifi cation de pression d’admission sur la soupape à l’aide d’un tube de 1/4” Di. Vérification de Pression la pression d’admission d’admission...
  • Page 8 Apposez les étiquettes de conversion Complétez l’assemblage du foyer 1. Collez l’étiquette montrant les nouvelles spécifi ca- Replacez la plinthe, les portes des côtés et le pare- tions par-dessus les spécifi cations correspondantes étincelles. sur la carte d’identifi cation du foyer située dans la Consultez le Guide d’installation du foyer pour tous les caisse du foyer, à...