Cradle Problems - Symbol PDT 7200 Series Product Reference Manual

Hide thumbs Also See for PDT 7200 Series:
Table of Contents

Advertisement

Symptom
Battery life is inadequate
Cannot access flash drive

Cradle Problems

Table 11-2
lists some common cradle problems and actions to take to resolve them.
Symptom
No communication between
terminal and cradle
Table 11-1. Terminal Problems (Continued)
Possible Cause
Battery is not fully charged.
Battery is old.
Terminal being used in low-
temperature conditions.
Unnecessary peripherals
draining power.
The application is not
designed for efficient power
use.
Drive not formatted.
Table 11-2. Cradle Troubleshooting
Probable Cause
Cradle in use.
Optical window obstructed or
dirty.
Terminal not seated properly
in cradle.
Troubleshooting and Maintenance
Action
Charge the battery, either in the
terminal or separately for a full 2
hours.
Replace with a fresh, fully
charged battery.
Battery life is shortened if used
in extremely cold conditions.
Disconnect any peripherals not
being used to reduce the drain
on the battery pack.
Consider using power
management services provided
in the Series 7000 SDK to
reduce drain on battery pack.
Format the drive or download a
new disk image using TCM and
IPL.
Action
Wait until available.
Remove obstruction or clean
the optical window.
Reseat the terminal in cradle.