Removal Of The Ods; Removal / Replacement Of The Radiants - Flavel Misermatic FRCM1G Installation And Maintenance Instructions Manual

Flavel misermatic frcm1g; misermatic frcm2g fireplaces
Table of Contents

Advertisement

Fig. 12
Control Valve Panel Removal
h)
To refit the control valve, reassemble in reverse order noting that the
control tap locates with a flat in the control fixing panel. Carry out a gas
soundness test after re-assembly.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the ther-
mocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Loosen the gas pipe nut and remove gas pipe from the pilot. This can
be accessed from under the base of the fire.
b)
Unscrew the pilot fixing screws. These can be accessed either from
under the base of the fire, or from the rear of the fire via two cut-outs in
the rear panel.
c)
Remove the push fit thermocouple as described in section 4.3.
4.5

REMOVAL / REPLACEMENT OF THE RADIANTS

Remove the radiants by lifting them slightly then pulling forward as shown
in Fig. 13 overpage