Removal Of The Ods; Removal / Replacement Of The Radiants - Flavel Regent FRGCP0MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

d)
Remove the thermocouple, which is a push fit into the rear of the control
valve.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the front panel and front bezel as described in section 4.2
b)
Unscrew the pilot fixing screws. These can be accessed from the front
of the appliance with the front panel and bezel removed.
c)
Remove the thermocouple as described in section 4.3. (d)
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.
4.5

REMOVAL / REPLACEMENT OF THE RADIANTS

Remove the radiants by lifting them slightly then pulling forward as shown
in Fig. 12 below.
Fig. 12
19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Regent frgcn0mn

Table of Contents