Removal Of The Ods - Flavel Emberglow Classic FEMC00MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

d)
Remove the valve retaining screws as shown below in Fig. 17
Fig. 17
e)
Remove the thermocouple, which is a push fit into the rear of the control
valve.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the pilot retaining screws as described in section 4.2 d) &
fig. 14
b)
Disconnect the pipe pipe and push fit ignition lead
c)
Replacement new ODS in reverse order, and carry out a gas tightness
test.
PARTS SHORTLIST
Replacement of any parts must be carried out by a competent person such as a
CORGI registered gas installer. The part numbers of the replaceable parts are as
follows, these are available from specialist spares stockists whose details can be
found on our web site,www.cfm-europe.com, in the 'stockist' section.
Coal set
FC-P085332 ODS Pilot (NG)
Fuelbed
FC-P085339 ODS Pilot (LPG)
Gas valve (NG)
B-63250
Rear Fibre board
B-65320
Glass Assy (Front)
SFA-085165
Gas Valve (LPG)
20
2 off valve
retaining screws
B-48360
B-66920
B-66930