Removal Of The Ods - Flavel Renoir FRECR0MN Installation And Maintenance Instructions Manual

Radiant convector gas fire
Table of Contents

Advertisement

d)
Remove the valve retaining screws as shown below in Fig. 15
Fig. 15
d)
Remove the thermocouple, which is a push fit into the rear of the control
valve.
e)
Re-assemble in reverse order and carry out a gas tightness test.
4.4
REMOVING THE ODS- PILOT ASSEMBLY
Note : Because this appliance is fitted with an atmosphere sensing ODS-pilot
it is not possible to replace the thermocouple separately, because the
thermocouple position is factory set to a tight tolerance. Any replacement of
parts on the pilot requires a complete new pilot assembly.
a)
Remove the pilot retaining screws as described in section 4.2 d) &
fig. 14
b)
Disconnect the pipe pipe and push fit ignition lead
c)
Replacement new ODS in reverse order.
Note : Prior to replacing the oxypilot on this product due to suspected
failure of the component, please remove all debris that has collected on
the lint guard of the oxypilot itself.
PARTS SHORTLIST
Replacement of any parts must be carried out by a competent person such as a CORGI registered gas
installer. The part numbers of the replaceable parts are as follows, these are available from specialist
spares stockists whose details can be found on our web site,www.bfm-europe.com, in the 'stockist' sec-
tion.
Coal set
Fuelbed
Rear Fibre board
FC-P085332
ODS Pilot
B-123570
Gas valve
B-65320
Glass Assy (Front)FC-A085705
19
2 off valve
retaining screws
B-48360
B-63250

Hide quick links: