Flavel Linear Pebble FRDPU0MN User Instructions

Decorative pebble fuel effect gas fire

Advertisement

Linear Pebble
DECORATIVE PEBBLE FUEL EFFECT GAS FIRE
User Instructions
These instructions should be read by the user before operating the
appliance and retained for future reference
Model No's FRDPU0MN is for use on Natural Gas (G20) at a supply
pressure of 20 mbar in G.B. / I.E.

Advertisement

Table of Contents
loading

Summary of Contents for Flavel Linear Pebble FRDPU0MN

  • Page 1 Linear Pebble DECORATIVE PEBBLE FUEL EFFECT GAS FIRE User Instructions These instructions should be read by the user before operating the appliance and retained for future reference Model No’s FRDPU0MN is for use on Natural Gas (G20) at a supply pressure of 20 mbar in G.B.
  • Page 2: Installation Information

    INSTALLATION INFORMATION CONDITIONS OF INSTALLATION It is the law that all gas appliances are installed only by a competent (e.g. CORGI Registered) Installer, in accordance with the installation instructions and the Gas Safety (Installation and Use) Regulations 1998. Failure to install appliances correctly could lead to prosecution.
  • Page 3: Important Safety Information

    ABOUT YOUR NEW LINEAR PEBBLE FIRE The Flavel Linear range of pebble fuel-bed gas fires incorporates a unique and highly developed fuel bed which gives the realism of a loose pebble layout combined with realistic flames and glow. The use of durable ceramic material in the construction of the fuel-bed components ensures long and trouble free opera- tion.
  • Page 4: Operating The Fire

    The ceramic pebble fuel-bed remains hot for a considerable period after use and sufficient time should be allowed for the fire to cool before cleaning etc. The fire must only be operated with the Linear trim supplied with the fire OPERATING THE FIRE The controls are located behind the ashpan cover below the Linear trim.
  • Page 5: Spillage Monitoring System

    SPILLAGE MONITORING SYSTEM This appliance is fitted with a spillage monitoring system which shuts down the fire if the evacuation of combustion products from the fire is affected by a partially or fully blocked flue. If this system operates the fire will go out. If this occurs, leave the fire for at least three minutes then follow the lighting procedure as described in the previous section.
  • Page 6: Re-Assembling The Ceramics And Fuel Bed

    RE-ASSEMBLING THE CERAMICS AND FUEL BED NOTE : The position of the fuel-bed components are critical to the performance of the product. Therefore please ensure that the fuel-bed components are positioned as described in the following section prior to requesting a service call due to soot build up, poor flame pattern etc. Place the ribbed ceramic fuelbed base on top of the fuelbed support and pull fully forwards to the burner.
  • Page 7 Pick pebbles A to E and arrange along the the front rail, ensuring that they are evenly spaced. Use the recess’s in the front ceramic rail as a guide for placement. (See fig. 3 below) Fig. 3 Pebble C Pebble D Pebble A Pebble E Pebble B...
  • Page 8 Select pebbles K, L & M and arrange along the rear of the fuelbed, using the ribs in the rear of the fuelbed as a guide for placement. (See fig. 5 below) Fig. 5 Pebble J Pebble N Pebble M Pebble L Pebble K Select the two small pebbles (J &...
  • Page 9: User-Replaceable Parts

    REMOVAL / RE-FITTING OF THE LINEAR TRIM The trim is secured onto the firebox flange by the use of magnets. USER REPLACEABLE PARTS The only user replaceable parts on this fire are the fuelbed components and pebbles which may be replaced as described in the above section. Replacement of any other parts must be carried out by a competent person such as a CORGI registered gas installer.