Flavel Misermatic FRCM1G Installation And Maintenance Instructions Manual page 11

Flavel misermatic frcm1g; misermatic frcm2g fireplaces
Table of Contents

Advertisement

Closure plate.
a)
Fit the closure plate to the fireplace opening and ensure that it has a flat
sealing area of at least 10mm sealed on all sides. See diagram below
Dimensions stated are for closure plate supplied
660mm
Check the operation of the chimney as follows:-
Apply a smoke match to the flue spigot opening in the closure plate and observe
the smoke. If there is a definite flow into the opening then proceed with the instal-
lation. If there is not a definite flow into the opening, pre-heat the chimney for
about two minutes and retest for flow. If there still is no definite flow into the open-
ing, the chimney may require attention. DO NOT FIT THE FIRE-SEEK EXPERT
ADVICE.
Hearth Fitting
a)
The feet must be fitted when hearth fitting.
Note :
When the fire is to be fitted onto a very smooth surface eg marble or
tiles.
The 2 off self adhesive foam rubber discs, supplied should be stuck on
to the levelling screws at the front of the fire.
b)
Carefully place the fire on the hearth. Slide the fire backwards up to the
closure plate, ensuring that the flue spigot passes through the hole In
the closure plate.
c)
Level the fire by adjusting the levelling screws at the front of the feet.
d)
Proceed with the gas connection as in section 2.3
460mm
Spigot Opening
493mm to
CTR
305mm Minimum
440mm Maximum
11
Fireplace
Opening
Dimensions
Closure
Plate
Dimensions
522mm Minimum
650mm Maximum
Minimum 10mm
Flat Sealing Area

Advertisement

Table of Contents
loading

This manual is also suitable for:

Misermatic frcm2g

Table of Contents