APPLIANCE DATA

Main injector (1 off)
Pilot Type.
Max. Gross Heat Input :
Min. Gross Heat Input :
Cold Pressure :
Ignition :
Electrode Spark Gap :
Weight (Packed) :
Firebox Dimensions (with case fitted)
Width:
Height:
Depth:
Height to top of the flue spigot : 525mm (with feet fitted)
Gas Connection :
Efficiency Declaration
The efficiency of this appliance has been measured as specified in
BS 7977-1 : 2002 and the result is 75%.
The gross calorific value of the fuel has been used for this efficiency
calculation. The test data from which it has been calculated has been certified by
Advantica. The efficiency value may be used in the UK Governments Standard
Assessment Procedure (SAP) for energy rating of dwellings.
Stereomatic Elbow size 76
Copreci Single Flame 21100 / 161
6.9 kW
2.5 kW
20.0 +/- 1.0 mbar (8.0 +/- 0.4 in w.g.)
Rotary piezo, integral to gas valve
4.0 mm
24 kg
800mm
636mm
210mm
8mm compression
(Supplied with fire)