Before making the final gas connection, thoroughly purge the gas supply
pipe work to remove all foreign matter, otherwise serious damage may be
caused to the gas control valve on the fire.
2.4
GAS TIGHTNESS
a)
Remove the pressure test point screw from the inlet elbow and fit a
manometer.
b)
Turn on the main gas supply and light the fire as described in section
3.2 and carry out a gas tightness test.
c)
Check that the gas pressure is 20.0 mbar (± 1.0 mbar), 8.0 in w.g. +/-
0.4 in w.g.
d)
Turn off the fire, remove the manometer and refit the pressure test point
screw. Check the pressure test point screw for gas tightness with the
appliance turned on using a suitable leak detection fluid or detector.
3.1

Completing the Assembly

a)
Fit the radiants by carefully inserting the upper end first into the radiant
canopy, and then lowering and seating the base of the radiants into the
radiant support channel.
b)
Pull off the control knob.
c)
Fit the outer case by hooking rear edge of the case over the retaining
lugs at each end of the rear panel.
d)
Ensure that the control bezel situated in the right hand side of the case
clears the control valve spindle.
e)
Re-fit the outer case fixing screws situated at the front as shown in Fig.
3 & 4 (page 9 &10 respectively)
f)
Refit the control Knob.
3.2

Lighting the Appliance

a)
Light the pilot by depressing the control knob at the "off" position and
turn anti-clockwise (with the control depressed) to the second position
marked *.
b)
When the pilot lights, (pilot can be seen through the bottom window of
right hand radiant) hold the control knob down for 10 seconds.
c)
If the pilot fails to light, repeat the ignition sequence and hold in the
control knob for slightly longer.
d)
When the pilot has lit, release the control knob from the depress
position, depress slightly again and turn the control anti-clockwise to the
large flame position and check for clearance of combustion products as
detailed below.