Maintenance Instructions; General Access For Servicing; Removal Of The Outer Case - Flavel Misermatic FRCM1G Installation And Maintenance Instructions Manual

Flavel misermatic frcm1g; misermatic frcm2g fireplaces
Table of Contents

Advertisement

Servicing Notes
Servicing should be carried out annually by a competent person such as a
Corgi registered engineer.
The service should include visually checking the chimney and fire opening for
accumulations of debris and a smoke test to check for positive up-draught in
the chimney.
The condition of the ceramic should be checked and if necessary the whole
set should be replaced with a genuine replacement set.
After any servicing work a gas tightness check must always be carried out.
4.1

GENERAL ACCESS FOR SERVICING

4.1.1
TO REMOVE THE OUTER CASE.
a)
Prepare work area (lay down dustsheets etc.)
b)
Remove control knob.
c)
Remove two lower outer case fixing screws, and the two upper outer
case fixing screws (see fig.7 & 8) and lift the case upwards and away.
d)
Remove the radiants and move to a safe place
e)
Re-assemble in the reverse order.
Fig. 7
Removing the Lower Outer Case Fixing Screws

MAINTENANCE INSTRUCTIONS