Troubleshooting - Superior DRL4543TEN Installation And Operation Instructions Manual

Direct-vent linear gas fireplace
Table of Contents

Advertisement

WARNING: Turn off fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
CAUTION: Never use a wire, needle or similar object to clean
pilot. This can damage pilot unit.
Note: All troubleshooting items are listed in order of operation.
OBSERVED PROBLEM
Pilot will not light
126718-01A

TROUBLESHOOTING

POSSIBLE CAUSE
1. No gas supply or shutoff
valve is OFF
2. Air in gas line
3. Construction debris clog-
ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve is not opening
7. No power to unit or ignition
module
www.SuperiorFireplaces.US.com
REMEDY
1. Check to see if you have
gas supply and that equip-
m e n t s h u t o ff v a l v e i s
opened
2. Repeat lighting procedure
several times to purge all
air out of lines. If after re-
peated attempts appliance
does not light, call for quali-
fied service and repair
3. Remove debris and dirt,
inspect and clean any other
possible obstructions
4. Contact your gas supplier
to check pressure
5. Have a qualified technician
replace pilot line
6. Replace control valve (Re-
fer to Replacement Parts,
page 33)
7. Check that main power is
on and that all wire connec-
tions are made correctly to
ignition model (see Wiring
Diagram, page 34).
35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Drl4543tep

Table of Contents