Superior DRL4543TEN Installation And Operation Instructions Manual page 14

Direct-vent linear gas fireplace
Table of Contents

Advertisement

Minimum
Pipe
Overlap
Direct
1
/
1
Vent
4
Pipe
Wall
Firestop
Maintain 1"
Minimum Air
Space Around
Outer Pipe When
Penetrating a Wall
11
/
" x 11
/
"
1
1
2
2
Framed Opening
Exterior Wall with Vinyl Siding
Figure 13 - Typical Horizontal
Termination Cap Mounting with
Additional Siding Standoff Installed
14
VENTING INSTALLATION
Continued
Siding
Standoff
Screws
High Wind
Termination
Apply
Mastic to
Outside
Edge of
Standoff
www.SuperiorFireplaces.US.com
Horizontal Termination Configurations
Figure 14 and 15, page 15, shows the configu-
rations for venting with horizontal termination
with a chart of critical minimum and maximum
dimensions which MUST be met.
NOTICE: Do not seal termination
cap to vent pipe. Cap must be
removable for vent inspection
and maintenance.
WARNING: Never run vent
downward as this may cause
excessive temperatures which
could cause a fire. Operation of
improperly installed and main-
tained venting system could
result in serious injury, property
damage or loss of life.
126718-01A