Superior DRL4543TEN Installation And Operation Instructions Manual page 15

Direct-vent linear gas fireplace
Table of Contents

Advertisement

GROUND FLOOR INSTALLATION
Recommended Applications:
• Through the wall using round or
square termination
(V) Vertical
Required
Minimum
Vertical Pipe
53"
1 ft.
65"
2 ft.
77"
3 ft.
V + H = 40 feet maximum
H = 20 feet maximum
Figure 14 - Horizontal Termination Using One 90° Elbow
Venting with Two 90°
Elbows
Vertical
Horizontal
(V)
(H
+ H
1
2
5' Min.
8' Max
6' Min.
10' Max
7' Min.
15' Max
20' Min.
20' Max
Figure 15 - Horizontal Termination Using Two 90° Elbows
126718-01A
VENTING INSTALLATION
V + 90· Elbow
(H) Horizontal
Maximum
7 ft.
11 ft.
20 ft.
)
www.SuperiorFireplaces.US.com
Continued
90° Elbow
1' Pipe Min. On
Horizontal Run
Wall
Firestop
Horizontal High
Wind Square
Termination
53'' Min.
Plus ¼''
Rise per
Foot
15