Superior DRT4036TEN Installation And Operation Instructions Manual

Superior direct-vent gas fireplace

Advertisement

P/N 126721-01 Rev B 01/2015
P126721-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns
from the hot viewing glass is provided with
this appliance and shall be installed for
the protection of children and other at-risk
individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property
damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the
fire department.
— Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
PFS
®
C
US
Report No. F09 -099
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec la
vitre chaude et doit être installé pour la protection Des
enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pourrait
d'entraîner des blessures graves, la mort ou des dom-
mages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz depuis
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
— L'installation et l'entretien doivent être assurés par un
For more information, visit Superiorfireplaces.US.com
Installation and Operation Instructions
Superior™ Direct-Vent Gas Fireplace
Models
DRT4036TEN
DRT4042TEN
AVERTISSEMENT
vapeurs ou liquides inflammables dans le voisinage de
cet appareil ou de tout autre appareil.
téléphones se trouvant dans le bâtiment où vous trouvez.
un voisin. Suivez les instructions du fournisseur.
le service des incindies.
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
DRT4036TEP
DRT4042TEN

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRT4036TEN

  • Page 1 Installation and Operation Instructions Superior™ Direct-Vent Gas Fireplace ® Models P/N 126721-01 Rev B 01/2015 DRT4036TEN DRT4036TEP Report No. F09 -099 DRT4042TEN DRT4042TEN P126721-01 INSTALLER: Leave this manual with the appliance. Installateur : Laissez cette notice avec l’appareil. CONSUMER: Retain this manual for future reference.
  • Page 2 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Table Of Contents

    Thank you for your purchase. We appreciate your TABLE OF CONTENTS business! Safety .....................3 Please carefully read and follow all instructions in this manual. Pay Local Codes ...................5 special attention to all warnings and safety information. Product Identification ..............5 Following these safety, care, and operation instructions will help Product Features ................5 ensure many years of dependable and enjoyable service from your Requirements for the Commonwealth of Massachusetts ....6...
  • Page 4 SAFETY Continued Carbon Monoxide Poisoning: Early signs of carbon monoxide poison- Installation and repair should be done by a qualified ing resemble the flu, with headaches, dizziness or nausea. If you have service person. The appliance should be inspected these signs, the fireplace may not be working properly. Get fresh air before use and at least annually by a professional at once! Have fireplace serviced.
  • Page 5: Local Codes

    SAFETY Continued LOCAL CODES 6. Have venting system inspected annually by a qualified service Install and use fireplace with care. Follow all local codes. In the ab- person. If needed, have venting system cleaned or repaired. See sence to local codes, use the current National Fuel Gas Code ANSI Cleaning and Maintenance, page 23.
  • Page 6: Requirements For The Commonwealth Of Massachusetts

    REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS COMMONWEALTH OF MASSACHUSETTS REQUIREMENTS Massachusetts Horizontal Vent Requirements These appliances are approved for installation in the US state of In the Commonwealth of Massachusetts, horizontal terminations Massachusetts if the following additional requirements are met: installed less than seven (7) feet above the finished grade must comply with the following additional requirements: •...
  • Page 7 PRE-INSTALLATION Continued (36") " " (42") Requires IHP 5” I.D. 8” O.D. Direct Vent Pipe (36") " " (42") (36") " (36") " " (42") 24" (42") (36") " 48" (42") (36") " (36") " " (42") 44" (42") (36") "...
  • Page 8 PRE-INSTALLATION Continued CLEARANCES Minimum clearances to combustibles for the fireplace are as follows: *Back and sides 1" Perpendicular walls 6" Floor 0" Ceiling to louver opening 42" (36") " Front 36" 48" (42") Top of Standoffs 0" Vent (See venting instructions for specific venting clearances.) (36") "...
  • Page 9: Location Of Termination Cap

    LOCATION OF TERMINATION CAP Fixed Openable Fixed Closed Closed Openable TERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA (TERMINATION PROHIBITED) A = clearance above grade, veranda, porch, deck, or I = clearance to service regulator vent outlet [*72" (182.9 cm) balcony [*12"...
  • Page 10: Venting Installation

    VENTING INSTALLATION NOTICE: Read these instructions completely before WARNING: This gas fireplace and vent assembly attempting installation. must be vented directly to the outside. The venting system must NEVER be attached to a chimney serving These models are tested and approved for use with an IHP (direct a separate solid fuel burning appliance.
  • Page 11 VENTING INSTALLATION Continued 5. Noncombustible Exterior Wall: Position horizontal vent cap in center of the 8 " round hole and attach to exterior wall with four wood screws Female provided. Before attaching vent cap to exterior wall, run a bead of non- Locking Lugs hardening mastic (pliable sealant) around outside edges to make a seal between it and outside wall.
  • Page 12 VENTING INSTALLATION Continued Horizontal Termination Configurations Cut Siding Away to Figure 15 shows a configuration for venting with horizontal termi- Fit Standoff nation with a chart of critical minimum and maximum dimensions which MUST be met. Standoff Wood Figure 16, page 13, shows a configuration for venting with horizontal Screw termination using two 90°...
  • Page 13 VENTING INSTALLATION Continued Flat Ceiling Installation 1. Cut an 11 " square hole in ceiling using locating hole as a center point. Opening should be framed to 11 " x 11 " inside dimen- sions, as shown in Figure 10 on page 11 using framing lumber the same size as ceiling joists.
  • Page 14 VENTING INSTALLATION Continued Note: If vent pipe passes through any occupied areas above first floor, including storage spaces and closets, you must enclose pipe. You may frame and sheetrock enclosure with standard construction material. Make sure and meet the minimum allowable clearances to combustibles. Do not fill any required air spaces with insulation.
  • Page 15: Fireplace Installation

    FIREPLACE INSTALLATION CHECK GAS TYPE IMPORTANT: Install main gas valve (equipment shutoff valve) in an accessible location. The main gas valve is for turning on or shutting Use proper gas type for the fireplace unit you are installing. If you off the gas to the appliance.
  • Page 16 FIREPLACE INSTALLATION Continued CONNECTING FIREPLACE TO GAS SUPPLY WARNING: Use pipe joint sealant that is resistant Installation Items Needed to liquid petroleum (LP) gas. • 5/16" hex socket wrench or nut-driver We recommend that you install a sediment trap/drip leg in supply line •...
  • Page 17 FIREPLACE INSTALLATION Continued REMOVING/REPLACING GLASS DOOR Equipment Shutoff Valve CAUTION: Do not operate this fireplace with a bro- Propane/LP ken glass door panel or without the glass door panel Supply Tank securely in place. For replacement part information see Replacement Parts, page 33. CAUTION: Wear gloves and safety glasses while handling or removing broken glass.
  • Page 18 FIREPLACE INSTALLATION Continued Replacing Glass Door 3. Place lava rock around base of burner. Make sure burner ports are not covered (see Figure 30, page 19). 1. Position door frame in front of firebox opening with bottom of 4. Place ember flakes around front and sides of burner and on burner door tilted away from firebox (see Figure 27).
  • Page 19 FIREPLACE INSTALLATION Continued To Gas Supply Lava Rock Equipment (Natural) Shutoff Millivolt Valve Control Valve To External Regulator (Propane/LP) Flexible Gas Line, Do NOT Kink Figure 30 - Installing Lava Rock Figure 33 - Connecting/Disconnecting Gas Line to Millivolt Valve WARNING: Never use an open flame to check for a leak.
  • Page 20 FIREPLACE INSTALLATION Continued INSTALLING BATTERIES IN WIRELESS HAND-HELD REMOTE BATTERY LIFE CONTROL AND RECEIVER Life expectancy of the alkaline batteries in the remote control should be at least 12 months. Check and replace all batteries annually. When Installing Batteries in Remote Receiver the remote control no longer operates the remote receiver from a 1.
  • Page 21: Operation

    OPERATION FOR YOUR SAFETY 5. Turn equipment shutoff valve clockwise to the OFF position READ BEFORE LIGHTING (see Figure 37). Do not force. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the WARNING: If you do not follow these instructions safety information.
  • Page 22: Inspecting Burners

    INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. BURNER FLAME PATTERN Burner flames will be steady, not lifting or floating. Flame patterns will PILOT ASSEMBLY be different from unit to unit and will vary depending on installation The pilot assembly is factory preset for the proper flame.
  • Page 23: Cleaning And Maintenance

    CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before CAUTION: Do not vacuum if pieces are hot. cleaning. Use only glass door replacement intended for this fireplace (see Replacement Parts, page 33 for detail on ordering). No substitutions CAUTION: You must keep control areas, burners may be made.
  • Page 24: Troubleshooting

    TROUBLESHOOTING WARNING: Turn off fireplace and let cool before servicing. Only a qualified service person should service and repair fireplace. CAUTION: Never use a wire, needle or similar object to clean pilot. This can damage pilot unit. Note: All troubleshooting items are listed in order of operation. OBSERVED PROBLEM POSSIBLE CAUSE REMEDY...
  • Page 25 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. •...
  • Page 26: Parts

    PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. 33(36") 32(42") Superiorfireplaces.US.com 126721-01B...
  • Page 27 PARTS This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 33 of this manual. DRT4036TEN DRT4036TEP DRT4042TEN DRT4042TEP CATALOG F1322 & F1323 F1324 & F1325 F1326 & F1327 F1328 &...
  • Page 28 PARTS BURNER ASSEMBLY Superiorfireplaces.US.com 126721-01B...
  • Page 29 33 of this manual. This table uses catalog numbers for clarity on models. WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. DRT4036TEN DRT4036TEP DRT4042TEN...
  • Page 30 PARTS REFRACTORY PARTS WARNING: Contact an IHP dealer to obtain any of these parts. Never use substitute materials not approved by IHP. Use of non-approved parts can result in poor performance and safety hazards. Herringbone Brick Shown Superiorfireplaces.US.com 126721-01B...
  • Page 31 PARTS REFRACTORY PARTS CATALOG PART NO. DESCRIPTION QTY. J7791 125124-02 Rear Refractory, Herringbone 42" Red • J7792 125088-02 Rear Refractory, Herringbone 36" Red • J7793 125123-02 Rear Refractory, Stacked 42" Red • J7794 125087-02 Rear Refractory, Stacked 36" Red • J7795 125126-02 Left Refractory, Herringbone 42"...
  • Page 32: Specifications

    SPECIFICATIONS DRT4036TEN DRT4036TEP • Rating: 33,500 Btu/hr • Rating: 31,000 Btu/hr • Gas Type: Natural Gas Only • Gas Type: Propane/LP Gas Only • Ignition: Electronic • Ignition: Electronic • Manifold Pressure: 3.5" w.c. • Manifold Pressure: 10" w.c. • Minimum Inlet Supply Pressure: 5" w.c.
  • Page 33: Replacement Parts

    REPLACEMENT PARTS ACCESSORIES Purchase these accessories from your local dealer. If they can not sup- Note: Use only original replacement parts. This will protect your ply these accessories call IHP at 1-800-655-2008 for information. You warranty coverage for parts replaced under warranty. can also write to the address listed on the back page of this manual.
  • Page 34 NOTES ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ Superiorfireplaces.US.com 126721-01B...
  • Page 35: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 36 WARRANTY KEEP THIS WARRANTY Model (located on product or id tag) Burner System _________ Cast Stove ___________ Serial No. (located on product or identification tag) ___________________ Date Purchased ______________________ Keep receipt for warranty verification. Innovative Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products.

This manual is also suitable for:

Drt4042tenDrt4036tep

Table of Contents