LCD Displays:
•
When activated, the LOCK icon will
appear in the MODE Zone.
•
If any touch-zone or button is
pressed when activated, the LCD
backlight will illuminate and the
LOCK icon will flash for 5 seconds
in the MODE Zone.
SENSOR SAFETY OVERRIDE
•
Will only operate if the control is in
MANUAL OFF mode.
•
Press and hold the FLAME Zone and the
UP Button simultaneously activate the
sensor safety override feature.
•
The module will ignore any sensor faults,
continually emit an igniter spark, and
energize the PILOT operator output.
DRL4543TEN
• Rating: 41,000/26,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 5" w.c.
• Maximum Inlet Supply Pressure: 10.5" w.c.
• Orifice: #31
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can't supply original replacement
part(s), call INNOVATIVE HEARTH PROD-
UCTS at 1-800-655-2008.
TECHNICAL SERVICE
You may have further questions about instal-
lation, operation, or troubleshooting. If so,
contact INNOVATIVE HEARTH PRODUCTS
at 1-800-655-2008. When calling please
have your model and serial numbers of your
heater ready.
You can also visit our web site at
www.IHP.US.com.
126718-01A
REMOTE CONTROL OPERATION
SPECIFICATIONS
REPLACEMENT PARTS
www.SuperiorFireplaces.US.com
Continued
•
When the buttons are released, the con-
trol will immediately return to MANUAL
OFF mode.
•
LCD Display:
•
When the Sensor Safety Override
feature is activated, CONT. PILOT
will flash on the LCD screen.
COMMUNICATION SAFETY
•
In manual ON and program modes of
operation, the transmitter will send a
communication safety transmission ev-
ery 15 - minutes. This signal is further
processed by the ignition control module
to verify the transmitter is communicat-
ing properly.
DRL4543TEP
• Rating: 39,000/25,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
• Maximum Inlet Supply Pressure: 13" w.c.
• Orifice: #49
When calling, have ready:
• your name
• your address
• model and serial numbers of your heater
• how heater was malfunctioning
• purchase date
Usually, we will ask you to return the part to
the factory.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (pro-
pane/LP units only)
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
33