Superior DRL3042TEN Installation And Operation Instructions Manual

Superior DRL3042TEN Installation And Operation Instructions Manual

Drl3000 linear direct-vent gas fireplaces

Advertisement

P/N 900079-02 Rev. B 05/2015
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900079-03.
P900079-02
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the
rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
Installation and Operation Instructions
Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces
PFS
Models
DRL3042TEN
®
C
US
Report No. F14-108
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
L'écran pare-étincelles fourni avec ce foyer réduit le
risque de brûlure en cas de contact accidentel avec
la vitre chaude et doit être installé pour la protection
Des enfants et Des personnes à risques.
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
• Si vous ne pouvez rejoindre le fournisseur de
— L'installation et l'entretien doivent être assurés par
DRL3042TEP
AVERTISSEMENT:
vapeurs ou liquides inflammables dans le voisin-
age de cet appareil ou de tout autre appareil.
servir des téléphones se trouvant dans le bâti-
ment où vous trouvez.
gaz depuis un voisin. Suivez les instructions du
fournisseur.
gaz, appelez le service des incindies.
un installateur ou un service d'entretien qualifié
ou par le fournisseur de gaz.
DRL3054TEN
DRL3054TEP

Advertisement

Table of Contents
loading

Summary of Contents for Superior DRL3042TEN

  • Page 1 Installation and Operation Instructions Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces P/N 900079-02 Rev. B 05/2015 Models Ce manuel est disponible en francais, simplement DRL3042TEN DRL3042TEP DRL3054TEN DRL3054TEP ® en faire la demande. Numéro de la pièce 900079-03. Report No. F14-108 P900079-02 INSTALLER: Leave this manual with the appliance.
  • Page 2 Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3 Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Safety and Your La sécurité et Seguridad y su Fireplace votre foyer chimenea All parts of your Toutes les parties de votre ¡Todas las partes de la...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: General Information

    Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 GENERAL INFORMATION IMPORTANT SAFETY INFORMATION L’information de sûreté importante Información importante de seguridad WARNING AVERTISSEMENT ADVERTENCIA Do not operate appliance with the Ne pas utiliser l’appareil si le...
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 FIREPLACE INSTALLATION, OPERATION, AND MAINTENANCE NOTICES DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION OF THE APPLIANCE OR ITS COMPONENTS. ANY MODIFICATION OR ALTERATION MAY VOID THE WARRANTY, CERTIFICATION, AND LISTINGS OF THIS UNIT.
  • Page 7 Innovative Hearth Products General Information Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 WARNING Clothing or other flammable material should not be placed on or near the appliance. AVERTISSEMENT On ne devrait pas placer de vêtements ni d’autres matières inflammables sur l’appareil ni à proximité.
  • Page 8: Packaging

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 INSTALLATION PACKAGING All models include The assembled vented gas fireplace heater is packaged with: • Literature Kit (Installation and Operation Instructions (this manual), and Safety-In-Operation Warning Labels) •...
  • Page 9 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Approved Vent Components These fireplaces are designed, tested and listed for operation and installation with the following vent components only: • Secure Vent Direct-Vent System Components, ® •...
  • Page 10 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Figure 1: Electronic Gas Valve Green Wire (from DFC Wire Harness) Line (IN) Test Port Manifold (OUT) Test Port Orange Wire (from DFC Wire Pressure Harness) Regulator Tower Main Gas Inlet 3/8"...
  • Page 11: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Orifice Sizes—Sea Level to High Altitude These fireplaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifice sizes (Table 5). For elevations above 4500 ft, contact your gas supplier or qualified service technician.
  • Page 12: Manufactured Home Requirements

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé dans une maison préfabriquée (mobile) déjà installée à demeure si les règlements locaux le permettent.
  • Page 13: Vent Termination Clearances

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 VENT TERMINATION CLEARANCES The following vent termination figures and charts should be used. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/ CGA-B149.1 in Canada.
  • Page 14 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 7: Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall...
  • Page 15: Minimum Clearances To Combustibles

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fireplace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exceptions: •...
  • Page 16: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Wall Finishes / Surrounds / Mantels Clearances to combustible mantels vary according to mantel depth (Figure 6). Mantels constructed of non-combustible material may be installed at any height above the appliance opening; however, do NOT allow anything to hang below the top edge of the fireplace door.
  • Page 17: Installation Sequence

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions.
  • Page 18 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 NOTE: Fireplace is designed for 1” thickness of non comustible board on the face of the unit. If the finished surface is to match a thinner finish material the unit must be recessed up to 1/2”...
  • Page 19: Route The Gas Supply Line Into The Fireplace

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Prepare the Fireplace Top Spacers 1. The two (2) 4 3/8” standoff spacers on top of the fireplace cabinet are shipped flat (Figure 8). 2. Bend the standoffs as shown (Figure 8): 3.
  • Page 20 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 • Check with the local building official for local code requirements (e.g., Are below grade penetrations of the gas line allowed?, etc). CAUTION If propane is used, be aware that with a tank that is too small (i.e., under 100 lbs, if this is the only gas appliance in the dwelling—see NPFA 58), there may be a loss of pressure.
  • Page 21 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Figure 11: When to use a vent restrictor Figure 12: Vent restrictor installation, Top vent Base Position 1 Position 2 U-Shaped 60 ft Maximum vertical run Vent Vent...
  • Page 22 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 1. Align the dimpled end over the collar, adjusting the radial alignment until the four (4) locking dimples are aligned with the inlet of the four (4) inclined channels on the collar (Figure 17).
  • Page 23: Clearance To Combustibles

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 17: Vent Section Length Nominal Section Nominal Section Length Length (in.) (in.) Net Section Length 10.5 22.5 34.5 46.5 Net Section Length (in.) 10.5 22.5 34.5 46.5 (in.)
  • Page 24: Install The Vent System

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 • 1” (25 mm) from all sides NOTE: Attic insulation shield (96K94) must be installed when blown or loose-fill insulation is used, and is recommended for all attic installations.
  • Page 25 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 2. Frame the ceiling opening—Use a plumb line from the ceiling above the fireplace to locate the center of the vertical run. Cut and/or frame an opening, 10 1/2 x 10 1/2” (267 x 267 mm) inside dimensions, about this center mark (Figure 21).
  • Page 26 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Maintain the required clearances to combustibles (Page 23). 9. Frame the roof opening—Identify the location for the vent at the roof. Cut and/or frame opening (Table 18). Table 18: Roof Framing Dimensions...
  • Page 27 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Vertical Vent Figures/Tables NOTE: Rise per foot run ratios are acceptable all the way to level. For best results, maintain the horizontal/inclined run in a straight (no dips), slightly elevated plane of approximately 1/4” per 1 ft (20 mm per 1 m).
  • Page 28 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 19: Top Vent—Two 90° Elbows Table 20: Top Vent—Three Elbows Vertical Firestop/ Spacer Horizontal Firestop/ Vertical Firestop/ Spacer Spacer  Horizontal Firestop/  Spacer   Maximum total H...
  • Page 29 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 30 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 8. Change vent direction—At transition from or to a horizontal/inclined run, install SV4.5E45 or SV4.5E90 elbows in the same manner as the straight vent sections. The elbows feature a twist section to allow them to be routed about the center axis of their initial collar section to align with the required direction of the next vent run element.
  • Page 31 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Figure 24: Installing the Horizontal Termination Firestop/Spacer (SV4.5HF) shown Typical Termination on the exterior side of the wall. It Shown may also be installed on the interior side.
  • Page 32 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 21: Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6–9 1/4” (152–235 mm) Termination Kit and 6”...
  • Page 33 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 23: Top Vent—Two 90° Elbows Maximum total H Minimum total V Horizontal Horizontal Firestop/ Termination  feet meters feet meters Spacer 0.610 0.305 1.372 0.914 1.829 1.220 2.286...
  • Page 34 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Vertical or Horizontal Venting Using Secure Flex Kits and Components Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5)
  • Page 35: Complete The Field Wiring

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 f. Install three (3) screws 120° apart through the flexible vent and into the adaptor collar just below the gear clamp to provide additional security to the connection.
  • Page 36 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 NOTE: The junction box can be moved to the bottom of the box (Figure 33). To move the junction box remove the cover plate, compress junction box to release it from the fireplace. Select the new location. For the bottom location, install the 3-wire 120 Vac supply wire and strain relief in the hole provided.
  • Page 37: Connect The Gas Line

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 WARNING Electronic models of these appliances are equipped with a three-prong (grounding) plug utilized in connecting the electronic components to the junction box in the lower compartment. This grounding plug provides protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle.
  • Page 38: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 NOTE: Seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fiberglass insulation. 1. Unscrew the shutoff valve from the gas flex-line. Apply thread sealant appropriate for the gas type, and then connect the shutoff valve to the gas stub.
  • Page 39: Install The Glass Media

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Install the Glass Media 1. See Page 55 for instructions on Installing the Glass Media. Install the Baffle NOTE: The baffle is factory-installed. Remove to install the vent restrictor (Page 20).
  • Page 40 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Air Shutter Adjustment Guidelines • If there is smoke or soot present, first ensure that the flames are not impinging on any of the panels. If the panels are properly positioned and a sooting condition still exists, increase the air shutter opening.
  • Page 41: Install The Finishing Materials

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Install the Finishing Materials NOTE: See Cold Climate Insulation on Page 11 and Vent Termination Clearances on Page 13. 1. Complete finished interior wall. Maintain a minimum 1” (25 mm) clearance from the door frame outer edge to any finish material.
  • Page 42 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Figure 38: Noncombustible Material with Cleanface Finish— Figure 39: Noncombustible Material with Surround— Profile View Profile View * 6” straight vent section * 6” straight vent Insulation and combustible Min.
  • Page 43 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 9. Reinstall door and secure with three screws. 10. Install Gas Shutoff Valve Door (Figure 41). 11. Install barrier on barrier mounting brackets. Figure 40: Gas Shutoff Valve Bracket...
  • Page 44: Install The Wall Switch Receiver

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Install the Wall Switch Receiver 1. When wall finish is complete, install the wall switch receiver in the previously installed junction box, and connect the 2-wire terminal to the connector on the back of the receiver.
  • Page 45: Attach The Safety-In-Operation Warnings

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 46: Installation Accessories

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 INSTALLATION ACCESSORIES Table 27: Listed Secure Vent Components ® Catalog Number Model Description Catalog Number Model Description The following flashing comes packaged with a storm collar Horizontal Square 77L78 SV4.5F...
  • Page 47 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Table 27: Listed Secure Vent Components ® Catalog Number Model Description Catalog Number Model Description Through Wall Shield Kit (to Attic Insulation Shield shield direct- H5816 SV4.5-TWSK10 H3907 SV4.5ARSA...
  • Page 48: Gas Conversion Kits

    Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion, or the production of carbon monoxide may result;...
  • Page 49 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Installing Gas Conversion Kits WARNING The gas supply shall be shut OFF prior to disconnecting the electrical power, before proceeding with the conversion. AVERTISSEMENT Avant d’effecteur la conversion, coupez d’abord l’alimentation en gaz, ensuite, coupez l’alimentation electrique.
  • Page 50 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 11. Make valve electrical connections. 12. Remove the pilot hood assembly to access the hex pilot orifice (Figure 50). Remove and replace the pilot orifice with the one provided with the kit. Exercise extreme care to prevent damage to or breakage of the igniter assembly.
  • Page 51: Operation

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 52 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 ATTACH THE SAFETY-IN-OPERATION WARNINGS NOTE: It is the installer’s responsibility to ensure these warnings are properly affixed during installation. These warning labels are a critical step in informing consumers of safe operation of this fireplace.
  • Page 53 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Burn-in Period The first few times this fireplace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process. Depending on usage, the burn-in period may take a few hours or a few days.
  • Page 54 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 • REMOTE (remote control) Detailed lighting instructions are found on Page 63. Also, electronic fireplace lighting instructions are attached to the CPI/IPI switch bracket. The fireplace main burner can be turned ON/OFF with the wall switch or remote control. Check the batteries, at least every three (3) months to ensure they are properly charged (Figure 2).
  • Page 55 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Continuous Pilot Ignition / Intermittent Pilot Ignition Switch These fireplaces have a continuous pilot ignition (CPI) / intermittent pilot ignition (IPI) switch installed under the door. This switch allows the pilot to be switched from intermittent mode to continuous mode: •...
  • Page 56 Innovative Hearth Products Installation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 2. Spread the glass media in a thin layer, evenly around the burner (Figure 56). Do NOT mound the media. Figure 51: Installing the glass media Do NOT place...
  • Page 57 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Installing and removing the glass door WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. • Remove glass door only when fireplace is OFF and COLD.
  • Page 58 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated firmly. Ensure it is properly located.
  • Page 59: Maintenance

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 MAINTENANCE Refer to the Maintenance Schedule on Page 61 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fireplace operation after servicing.
  • Page 60 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated firmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 61 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 31: Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By...
  • Page 62: Optional Accessory Components

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 OPTIONAL ACCESSORY COMPONENTS Surround Kits Surround kits should be used for a finished appearance. Table 33: Surround Kits Catalog No. Model No. Description F2261 LDV42-SB Black Satin, 42” models...
  • Page 63: Lighting Instructions

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 64 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 65: Troubleshooting

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 TROUBLESHOOTING Before troubleshooting, ensure that the fireplace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fireplace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 66: Replacement Parts

    Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 REPLACEMENT PARTS Contact an IHP dealer to obtain any of these parts. Contact IHP for the phone number of your nearest IHP dealer. Table 39: Installer Replacement Parts 42”...
  • Page 67 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 Figure 53: Replacement Parts Power 120V Power 120V Power Power 120V 120V Table 40: Homeowner Replacement Parts 42” 54” Description Catalog Number Catalog Number Remote Control Transmitter Kit...
  • Page 68 Innovative Hearth Products Operation Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 NOTES...
  • Page 69: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand gas fireplace, Stove or Insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 70 Innovative Hearth Products Installation and Operation Instructions Superior™ DRL3000 Linear Direct-Vent Gas Fireplaces 900079-02 05/2015 SuperiorFireplaces.US.com Record the following important information about your fireplace: Fireplace model number Fireplace serial number Date fireplace was Installed Type of gas fireplace uses Dealer name...

This manual is also suitable for:

Drl3054tenDrl3054tepDrl3042tep

Table of Contents