Heating System Operation; Biowin 2 With Mesplus System Control - Windhager BioWIN 2 Operating Manual

Pellet central heating boiler
Hide thumbs Also See for BioWIN 2:
Table of Contents

Advertisement

2.
Operation

2.10 Heating system operation

The BioWIN 2 should not be switched off with the On/Off switch
power supply via the power plug. The heating system should be shut down by switching it off at the control system
(see section 2.10.1 and 2.10.2).
Attention!
The anti-freeze function is not active when the boiler is shut off (ON/OFF button
Information!
The block protection for cleaning the heating surfaces and for the ash conveyor (is switched on
briefly every day at 12.00) is not active when the boiler is switched off (ON/OFF button

2.10.1 BioWIN 2 with MESplus system control

Information!
For operation of the MESplus and related user modules, please see their respective Operating
instructions.
Boiler switching on, MESplus system control to automatic operation:
1. Press the ON/OFF button
lamp lights green and a self-test is performed (see also section 2.6.2). After a successful self-test and if a
setpoint is transferred by the system control, the BioWIN 2 automatically starts operation.
2. Set the operating mode switch(es) on the MESplus control module(s) to "Automatic operation"
stem operation (setting temperatures and operating times) is performed using the user module (installed in
the living area) – for more details, please refer to the instructions.
Fig. 118 BioWIN 2 with MESplus system control
Switching off heating system:
Set the operating mode to "Standby"
on the InfoWINplus panel, the lighting and display are switched on, the signal
using the user module (installed in the living area).
44
on the InfoWINplus or disconnected from the
InfoWINplus operating unit
ON/OFF button
Operating mode switch
) .
).
. The sy-