4.2.3.4 CR Motor Assembly Removal

This section describes procedure for removing the motor unit which drives
the carriage mechanism (mirror/lamp).
1. Remove the scanner mechanism. (See Section 4.2.2.2.)
2. Turn the mechanism over and place it on a flat surface.
3. Unhook the torsion spring from the tension lever assembly, then
remove 1 screw (No.6) to remove the tension lever assembly.
4. Disconnect the cable for the motor from the relay connector and
remove 4 CR damper shafts; B (No.8) securing the motor, then remove
the motor.
ü ü ü ü
When assembling, hook the spring to the tension
CHECK POINT
lever assembly first, then fasten the screw.
Rev. A
Bottom of the Scanner Facing Upward
Motor (CR) Assembly
CR Damper Shafts ;B
(No.8)
Figure 4-13. CR Motor Assembly Removal
Disassembly and Assembly
Tension Lever Assembly
Torsion Spring
Screw (No.6)
4-10