7.1 CONNECTOR SUMMARY
This section describes all connectors on the control board for the ADF and
their corresponding signals and functions.
Table 7-1. Connector Pin Assignment (CN1)
Pin
Signal
I/O
No.
name
destination
Document
1
+5V
width
detection
2
DWVR
volume
3
SGNG
4
+5V
5
SGND
Empty sensor
6
EMP
7
+ 5V
Paper feed
8
SGND
motor sensor
9
KM CLK
10
+5V
11
TIMS
Timing sensor
12
TIMS DA
13
AN+24V
Registration
sensor
14
REGE
15
RDDLED
Rev. A
Signal
Function
level
Inputs +5VDC for the volume
+5V
resistance.
Outputs document width
0-5V
detection signal.
----
GND
Inputs +5VDC applied to the
+5V
empty sensor.
----
GND
Outputs paper empty sensor
0 or 5V
signal
Inputs +5VDC for the photo-
+5V
interrupter sensor.
----
GND
Outputs motor rotation amount
Pulse signal
signal.
Inputs +5VDC for the photo-
+5V
interrupter sensor.
- 3V or more:
Outputs paper empty/presence
Present
- 1V or less:
detection signal.
Empty
Inputs LED drive signal.
- Pre-feeding almost complete
- 3.8V: LED = On
- 5V:
LED = Off
-
Whole document through
Inputs +24VDC applied to the
+24V
photo-interrupter sensor.
- 0.3 - 5V :
Present
Outputs paper empty/presence
- 1 - 15V :
detection signal.
Empty
Inputs the LED light amount
0 - 24V
control signal.
Pin
Signal
No.
name
1
*B
2
B
3
*A
4
A
5
+24V
6
+24V
Pin
Signal
No.
name
DFM 1
2
DFM 2
3
DFSOL
4
+24V
5
FGOD
6
ADF +24V
7
AUOD
8
DC +24V
9
----
: On
: Off
Table 7-2. Connector Pin Assignment (CN2)
I/O
Signal
destination
level
Pulse signal
Transportation
motor
+24V
Table 7-3. Connector Pin Assignment (CN3)
I/O
Signal
destination
level
Paper feed
Pulse signal
motor
Paper feed
Pulse signal
solenoid
Paper feed
+24V
solenoid
- 0V: Open
Paper feed
- 24V: Close
cover open/
close sensor
+24V
ADF open/
close sensor
----
----
Appendix
Function
Outputs transportation motor
drive signal change trigger.
Outputs +24VDC for motor drive.
Function
Outputs paper feed motor drive
signal change trigger.
Outputs solenoid drive signal
change trigger.
Outputs voltage for inducing
solenoid.
Inputs paper feed cover
open/close status signal.
Outputs +24VDC for inducing
solenoid.
Inputs ADF open/close status
signal.
Outputs +24VDC for the ADF
open/close sensor.
----