Epson GT-1200 Service Manual page 48

Color image scanner
Table of Contents

Advertisement

GT-12000
3. Remove 9 screws and remove the glass frame assembly. The screws
to be removed and their locations are as follows:
· No.4: 5 screws securing the glass frame assembly by the right
and left sides.
· No.1: 2 screws securing the glass frame assembly by the rear
edge.
· No.3: 2 screws securing the glass frame assembly by the front
edge.
Note: Directions are described when the scanner is viewed from
the front.
CAUTION
When reinstalling the glass frame assembly, refer
to Section 4.2.3.5.1 to set the glass frame assembly
on the correct position. Failure in this operation
will cause the CR to start scanning at a wrong
position.
Rev. A
Glass Fixing Plate
(Color : Silve)
Screws (No.1)
Screws
(No.4)
Screws (No.3)
Front Side of the Scanner
Figure 4-16. Glass Frame Assembly Removal
Disassembly and Assembly
Glass Frame Assembly
Glass Fixing Plate
(Color : Silve)
Screws
(No.4)
4-12