    Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6027TR- D71RF/D71QRF/D71FRF. Installation and maintainance should be performed by experienced technicians only. The SuperServer 6027TR-D71RF/D71QRF/D71FRF is a high-end server based on the SC827HD-R1K28B 2U rackmount chassis and the dual processor X9DRT-HF/ HIBQF/HIBFF serverboard.
  • Page 4 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF SUPERSERVER Chapter 4: System Safety You should thoroughly familiarize yourself with this chapter for a general overview of safety precautions that should be followed when installing and servicing the SuperServer 6027TR-D71RF/D71QRF/D71FRF. Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DRT-HF/HIBQF/HIBFF serverboard, including the locations and functions of connections, headers and jumpers.
  • Page 5 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF SUPERSERVER Notes...
  • Page 6: Table Of Contents

    Mounting Rails ....................1-5 Advanced Power Management ............... 1-5 Intel® Intelligent Power Node Manager (NM) ..........1-5 Manageability Engine (ME) ................1-5 Contacting Supermicro ..................1-7 2U Twin: System Notes ................... 1-8 Nodes ......................1-8 System Power ....................1-8 SATA/SAS Backplane/Drives ................1-8 Chapter 2 Server Installation Overview ......................
  • Page 7 Table of Contents Rack Mounting Considerations ............... 2-3 Ambient Operating Temperature ..............2-3 Reduced Airfl ow ..................2-3 Mechanical Loading ................... 2-3 Circuit Overloading ..................2-3 Reliable Ground ..................2-3 Installing the System into a Rack ..............2-4 Separating the Sections of the Rack Rails ............. 2-4 Installing the Inner Rail Extension ..............
  • Page 8 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF SUPERSERVER Processor and Heatsink Installation..............5-3 Installing a Passive CPU Heatsink ..............5-7 Removing the Heatsink ................... 5-8 Installing Memory .................... 5-9 Memory Support ....................5-9 Maximum Memory ................... 5-9 DIMM Module Population Confi guration ...........5-11 Adding PCI Expansion Cards ............... 5-12 Motherboard Details ..................
  • Page 9 Table of Contents 6-10 Installing and Replacing the Adapter Card ........... 6-15 Expansion Card/Expansion Slot Setup ............6-15 Installing the Riser Card onto the Riser Card Bracket ......... 6-16 Installing Add-On and Riser Cards onto the Motherboard ......6-17 6-11 Installing and Removing Hard Drives ............
  • Page 10 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF SUPERSERVER Notes...
  • Page 11: Chapter 1 Introduction

    One (1) SAS Backplane for 12 3.5" HDD (BPN-SAS-827HD) Twelve (12) hot-swap 3.5" HDD trays (MCP-220-00075-0B) • Two (2) Riser cards (RSC-R2UT-3E8R-O-P) • One (1) Rails set (MCP-290-00053-0N) Note: a complete list of safety warnings is provided on the Supermicro web site at http://www.supermicro.com/about/policies/safety_information.cfm...
  • Page 12: Serverboard Features

    UDIMM in up to 512 MB, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB sizes at 1.35V or 1.5V voltages. See Chapter 5 for details. Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information.
  • Page 13: Onboard Controllers/Ports

    (additional one internal USB headers are included on the serverboard), an IPMI dedicated LAN port and two Ethernet ports. Note: For IPMI Confi guration Instructions, please refer to the Embedded BMC Confi guration User's Guide available @ http://www.supermicro.com/support/ manuals/. Graphics Controller The X9DRT-HF/HIBQF/HIBFF features an integrated Matrox G200eW Video Controller.
  • Page 14: Server Chassis Features

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Server Chassis Features The following is a general outline of the main features of the SC827 server chassis. System Power Each SC827 chassis model includes a high-effi ciency 80-plus Platinum certifi ed power supply, rated at 1280 Watts plus one redundant backup power supply. In the unlikely event your power supply fails, replacement is simple and can be accomplished without tools.
  • Page 15: Air Shrouds

    Chapter 1: Introduction Air Shrouds The SC827 chassis includes two mylar air shrouds that direct the airfl ow where cooling is needed on each serverboard. Always use the air shroud included with your chassis on each serverboard. Mounting Rails The SC827 includes a set of quick-release rails, and can be placed in a rack for secure storage and use.
  • Page 16: System Block Diagram

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 1-1. AMD C602 Chipset: System Block Diagram Note: This is a general block diagram and may not exactly repre- sent the features on your motherboard. See the previous pages for the actual specifi cations of your motherboard. This block diagram is intended for your reference only.
  • Page 17: Contacting Supermicro

    Chapter 1: Introduction Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 18: Twin: System Notes

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 2U Twin: System Notes As a 2U Twin confi guration, the SuperServer 6027TR-D71RF/D71QRF/D71FRF is a unique server system. With two system boards incorporated into a single chassis acting as two separate nodes, there are several points you should keep in mind. Nodes Each of the two serverboards act as a separate node in the system.
  • Page 19: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your SuperServer 6027TR- D71RF/D71QRF/D71FRF up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time. This quick setup assumes that your system has come to you with the processors and memory preinstalled.
  • Page 20: Choosing A Setup Location

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Choosing a Setup Location • Leave enough clearance in front of the rack to enable you to open the front door completely (~25 inches) and approximately 30 inches of clearance in the back of the rack to allow for suffi cient airfl ow and ease in servicing. •...
  • Page 21: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient temperature (Tmra).
  • Page 22: Installing The System Into A Rack

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Installing the System into a Rack This section provides information on installing the SC827 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 23: Installing The Inner Rail Extension

    Chapter 2: Server Installation Figure 2-2: Installing the Inner Rail Extensions Installing the Inner Rail Extension The SC827 chassis includes a set of inner rails in two sections: inner rails and inner rail extensions. The inner rails are pre-attached to the chassis, and do not interfere with normal use of the chassis if you decide not to use a server rack.
  • Page 24: Outer Rack Rails

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack 1.
  • Page 25: Checking The Serverboard Setup

    Chapter 2: Server Installation 3. Slide the inner rails into the outer rails, keeping the pressure even on both sides. When the chassis has been pushed completely into the rack, it should click into the locked position. 4. Optional screws may be used to secure the to hold the front of the chassis to the rack.
  • Page 26: Checking The Drive Bay Setup

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 2-5. Accessing the Inside of the System Remove two screws Check Ventilation Openings Checking the Drive Bay Setup Next, you should check to make sure the peripheral drives and the SATA/SAS drives have been properly installed and all connections have been made. Checking the Drives 1.
  • Page 27: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel and on the drive carriers to keep you constantly informed of the overall status of the system. SC827 models include two front panels on the handles of the chassis which control each of the systems. This chapter explains the meanings of all LED indicators and the appropriate response you may need to take.
  • Page 28: Control Panel Button

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Control Panel Button • Power: The main power button on each of the two control panels is used to apply or remove power from the power supply to each of the two systems in the chassis. Turning off system power with this button removes the main power, but keeps standby power supplied to the system.
  • Page 29: Drive Carrier Leds

    Chapter 3: System Interface Drive Carrier LEDs The server chassis uses SATA/SAS drives. SATA/SAS Drives Each SATA/SAS drive carrier has two LEDs. • Blue: Each Serial ATA drive carrier has a green LED. When illuminated, this green LED (on the front of the SATA/SAS drive carrier) indicates drive activity. A connection to the SATA/SAS backplane enables this LED to blink on and off when that particular drive is being accessed.
  • Page 30 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Notes...
  • Page 31: Chapter 4 Standardized Warning Statements For Ac Systems

    The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, Contact Supermicro's Technical Support department for assistance. Only certifi ed technicians should attempt to install or confi gure components.
  • Page 32 UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 33 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 34: Installation Instructions

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 35: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw.
  • Page 36: Power Disconnection Warning

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V,20A. Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components.
  • Page 37 Chapter 4: Warning Statements for AC Systems Le système doit être débranché de toutes les sources de puissance ainsi que de son cordon d'alimentation secteur avant d'accéder à l'intérieur du chassis pour ‫אזהרה מפני ניתוק חשמלי‬ installer ou enlever des composants de systéme. !‫אזהרה‬...
  • Page 38: Equipment Installation

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi ziertem Personal gestattet werden. ¡Advertencia! Solamente el personal califi...
  • Page 39: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 40: Battery Handling

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻓﻘﻂ‬...
  • Page 41 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 42: Redundant Power Supplies

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 43: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ Waarschuwing Deze eenheid kan meer dan één stroomtoevoeraansluiting bevatten. Alle aansluitingen dienen verwijderd te worden om het apparaat stroomloos te maken. Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is...
  • Page 44: Comply With Local And National Electrical Codes

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬ Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 45: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 46: Hot Swap Fan Warning

    UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement.
  • Page 47 Chapter 4: Warning Statements for AC Systems Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 48: Power Cable And Ac Adapter

    fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi ed cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. Warnung Bei der Installation des Produkts, die zur Verfügung gestellten oder benannt...
  • Page 49 Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi és qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
  • Page 50 UPER ERVER 6027TR-D71QRF/D71FRF/D71RF User's Manual Notes 4-20...
  • Page 51: Chapter 5 Advanced Motherboard Setup

    Chapter 5: Advanced Motherboard Setup Chapter 5 Advanced Motherboard Setup This chapter covers the steps required to install the X9DRT-HF/HIBQF/HIBFF motherboard into the chassis, connect the data and power cables and install add-on cards. All motherboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
  • Page 52: Rear I/O Ports

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Rear I/O Ports The rear I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-1 below for the colors and locations of the various I/O ports. Figure 5-1. Rear I/O Ports Back Panel I/O Port Locations and Defi...
  • Page 53: Processor And Heatsink Installation

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. Refer to the Supermicro website for updates on CPU support. Installing the LGA2011 Processor 1. There are two load levers on the LGA2011 socket. To open the socket cover, fi...
  • Page 54 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 2. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU socket from its locking position. Press down on Load the Pull lever away Lever labeled 'Close 1st' from the socket 3.
  • Page 55 Chapter 5: Advanced Motherboard Setup 5. Use your thumb and index fi nger to hold the CPU on its edges. Align the CPU keys, which are semi-circle cutouts, against the socket keys. Socket Keys CPU Keys 6. Once they are aligned, carefully lower the CPU straight down into the socket. (Do not drop the CPU on the socket.
  • Page 56 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 7. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly installed. 8. Close the load plate with the CPU inside the socket. Lock the lever labeled 'Close 1st' fi...
  • Page 57: Installing A Passive Cpu Heatsink

    Chapter 5: Advanced Motherboard Setup Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the required amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the Motherboard's and the Heatsink Bracket underneath.
  • Page 58: Removing The Heatsink

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Removing the Heatsink Caution: We DO NOT recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket. 1.
  • Page 59: Installing Memory

    (128-bit) memory, which is faster than non-interleaved (64-bit) memory.” Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information. Maximum Memory The X9DRT-HF/HIBQF/HIBFF serverboard supports up to 256 GB of ECC RDIMM memory or 64 GB of UDIMM memory in eight (8) DIMM slots.
  • Page 60 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 5-2. Installing DIMM into Slot To Install: Insert Notch Notch module vertically and press down until it snaps into place. Front View Pay attention to the alignment notch at the bottom. Note: Notch should align with To Remove: Use the receptive key point on the slot.
  • Page 61: Dimm Module Population Confi Guration

    Chapter 5: Advanced Motherboard Setup DIMM Module Population Confi guration For memory to work properly, follow the tables below for memory installation: UDIMM Support on the E5-2600 Series Processor Platform DIMMs Populated UDIMM Type POR Speeds Ranks per DIMM per DDR Channel (Unb.
  • Page 62: Adding Pci Expansion Cards

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Adding PCI Expansion Cards The 6027TR-D71RF/D71QRF/D71FRF includes two preinstalled riser cards designed specifi cally for use in the SC827HD-R1K28B 1U rackmount chassis. These riser cards support two full height and one low-profi le PCI Express x8 cards to fi...
  • Page 63: Motherboard Details

    Chapter 5: Advanced Motherboard Setup Motherboard Details Figure 5-3. X9DRT-HF/HIBQF/HIBFF Motherboard Layout (not drawn to scale) COM1 LEB2 JBR1 LEB1 LEM1 JRK1 RAID KEY JPME1 JPME2 JNMI1 JRST1 Controller InfiniBand Controller JPB1 JPL1 JSD1 JPG1 C602 Chipset BATTERY BIOS JBT1 CPU1 CPU2 5-13...
  • Page 64 1. For the latest CPU/Memory updates, please refer to our website at http:// www.supermicro.com/products/motherboard/ for details. 2. Use only the correct type of onboard CMOS battery as specifi ed by the manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
  • Page 65 Chapter 5: Advanced Motherboard Setup Connector Description COM1 Backplane COM Port1 Infi niBand Connector (X9DRT-HIBQF and X9DRT-HIBFF only) I-SATA 0/1 Intel PCH SATA Connectors 0/1 JBAT1 Onboard Battery (See the warning on P. 1-6.) SMC Proprietary Slot for Power, FP Control & I-SATA Connections JNMI1 NMI (Non-Maskable Interrupt) Header JIPMB1...
  • Page 66: Connector Defi Nitions

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Connector Defi nitions Ethernet LAN Ports LAN Ports (LAN1/2) Pin Defi nition Two Gigabit Ethernet ports (LAN1/2) Pin# Defi nition Pin# Defi nition are located on the I/O backplane on P2V5SB SGND the motherboard. In addition, an IPMI TD0+ Act LED Dedicated LAN is located above USB...
  • Page 67 Chapter 5: Advanced Motherboard Setup Serial Ports Serial Port Pin Defi nitions (COM1/COM2) The COM1 serial port is located beside Pin # Defi nition Pin # Defi nition the VGA port. Refer to the motherboard layout for the location of the COM2 header.
  • Page 68 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Unit Identifi er Switches UID Switch Two Unit Identifi er (UID) Switches and Pin# Defi nition two LED Indicators are located on the Ground motherboard. The Front Panel UID Ground Switch is located at Pin 16 on JF2. The Button In Rear UID Switch is located at SW1 next Ground...
  • Page 69 Chapter 5: Advanced Motherboard Setup System Reset System Reset (JRST1) Pin Defi nition A System Reset header is located at Pin Setting Defi nition JRST1 on the motherboard. Connect Pin 1 Signal a cable to this header for system Pin 2 Ground reset.
  • Page 70: Jumper Settings

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Jumper Settings Connector Pins Explanation of Jumpers To modify the operation of the motherboard, Jumper jumpers can be used to choose between optional settings. Jumpers create shorts between two pins to change the function Setting of the connector. Pin 1 is identifi ed with a square solder pad on the printed circuit board.
  • Page 71 Chapter 5: Advanced Motherboard Setup Watch Dog Enable/Disable Watch Dog (JWD1) Jumper Settings Watch Dog (JWD1) is a system monitor Jumper Setting Defi nition that can reboot the system when a Pins 1-2 Reset (default) software application hangs. Close Pins Pins 2-3 1-2 to reset the system if an application Open...
  • Page 72: Onboard Indicators

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL I2C Bus to PCI-Exp. Slots I2C to PCI-E (JI2C1/JI2C2) Jumper Settings Jumpers JI C1 and JI C2 allow you to Jumper Setting Defi nition connect the System Management Bus Enabled C) to PCI-Express slots. The default Disabled (Default) setting is Open to disable the connection.
  • Page 73 Chapter 5: Advanced Motherboard Setup BMC Heartbeat LED BMC Heartbeat LED (LEM1) Status A BMC Heartbeat LED is located at Color/State Defi nition LEM1 on the motherboard. When LEM1 Green: Blinking BMC:Normal is blinking, BMC functions normally. See the table at right for more information. Infi...
  • Page 74: 5-10 Pci-Express And Serial Ata Connections

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 5-10 PCI-Express and Serial ATA Connections PCI-Express 3.0 x16 Slot A PCI-Express 3.0 x16 slot (Slot 1) is located on the motherboard. Refer to the layout on page 5-14 for the locations. PCI-Express 3.0 x8 Slots Two PCI-Express 3.0 x8 slots (Slots SXB1/ SXB2) are on the motherboard.
  • Page 75: 5-11 Installing Drivers

    Chapter 5: Advanced Motherboard Setup 5-11 Installing Drivers The CD that came bundled with the system contains drivers, some of which must be installed, such as the chipset driver. After inserting this CD into your CD-ROM drive, the display shown in Figure 5-4 should appear. (If this display does not appear, click on the My Computer icon and then on the icon representing your CD-ROM drive.
  • Page 76: Supero Doctor Iii

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Supero Doctor III The SuperDoctor® III program is a Web base management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program included on the CD-ROM that came with your motherboard allows you to monitor the environment and operations of your system.
  • Page 77 Chapter 5: Advanced Motherboard Setup Figure 5-6. Supero Doctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/software/ SuperDoctorIII.cfm.For Linux, we recommend that you use the SuperoDoctor II application instead.
  • Page 78: 5-12 Onboard Battery

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 5-12 Onboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-x). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
  • Page 79: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC827HD-R1K28B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 80: Control Panel

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 6-1. Chassis Front View Node A Control Panel Node B Control Panel Hard Drives Figure 6-2. Chassis Rear View Dedicated IPMI Power PCI-Express x8 LAN Port Supply LAN Ports Cards COM Port VGA Port USB Ports Infi...
  • Page 81: Chassis Cover

    Chapter 6: Advanced Chassis Setup Chassis Cover Before operating the SC827HD chassis for the fi rst time, it is important to remove the protective fi lm covering the top of the chassis, in order to allow for proper ventilation and cooling. Removing the Chassis Cover and Protective Film 1.
  • Page 82: Installing The Air Shrouds

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Installing the Air Shrouds Air Shrouds Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC827HD chassis requires air shrouds for each motherboard node. Air shrouds vary depending upon the motherboard used. See the illustrations below. Installing an Air Shroud 1.
  • Page 83: Checking The Airfl Ow

    Chapter 6: Advanced Chassis Setup Checking the Airfl ow Checking Airfl ow 1. Make sure there are no objects to obstruct airfl ow in and out of the server. In addition, if you are using a front bezel, make sure the bezel's fi lter is replaced periodically.
  • Page 84 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Changing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan has failed. (Never run the server for an extended period of time with the chassis cover open.) 2.
  • Page 85 Chapter 6: Advanced Chassis Setup Figure 6-5. Replacing a System Fan in the Fan Housing...
  • Page 86: Removing And Installing The Backplane

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Removing and Installing the Backplane The SC827HD chassis backplane is located behind the hard drives and in front of the front system fans. If it is necessary to remove the backplane, follow the instructions below. Removing the Backplane Removing the Backplane from the Chassis 1.
  • Page 87 Chapter 6: Advanced Chassis Setup 7. Loosen the three screws in the spring bar, located on the fl oor of the chassis, indicated by the arrows below (Figure 6-7). Figure 6-7: Loosening the Spring Bar Screws in the Floor of the Chassis 8.
  • Page 88: Installing The Backplane

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Installing the Backplane Installing the Backplane into the Chassis (Figure 6-9) 1. Ensure that all of the hard drive trays have been removed from the bays in the front of the chassis and that the spring bar has been loosened as directed in the previous section.
  • Page 89: Installing The Motherboard

    Figure 6-10. I/O Shield Placement I/O Shields Compatible Motherboards Most Supermicro Twin series motherboards are compatible with the SC827HD chassis. For the most up-to-date information on compatible motherboards and other parts, visit the Supermicro Web site at www.supermicro.com. Hot-swappable motherboards feature different adapter cards, depending upon the motherboard.
  • Page 90 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Installing the Motherboard (Figure 6-11) 1. Review the documentation that came with your motherboard. Become familiar with component placement, requirements, precautions, and cable connections. 2. Pull the motherboard node drawer out of the back of the chassis. 3.
  • Page 91: Node Installation/Removal

    Chapter 6: Advanced Chassis Setup Node Installation/Removal As with any server system, power must be removed from the serverboard when upgrading or installing memory or processors. In the 2U Twin server, the serverboards (nodes) are capable of being hot-swapped from the chassis, allowing one to be powered down for servicing while the other continues operating.
  • Page 92 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 6-12. Removing a System Node Note: The above illustration above represents a typical motherboard in the node drawer and its attached components. It is not meant to represent the specifi c motherboard found in your server. 6-14...
  • Page 93: 6-10 Installing And Replacing The Adapter Card

    Chapter 6: Advanced Chassis Setup 6-10 Installing and Replacing the Adapter Card Expansion Card/Expansion Slot Setup The SC827HD chassis supports one low-profi le PCI slot and two full height full length slots for each node, for a total of six slots in the chassis (Figure 6-14). Figure 6-14: I/O Shield Confi...
  • Page 94: Installing The Riser Card Onto The Riser Card Bracket

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Installing the Riser Card onto the Riser Card Bracket Installing the Riser Card onto the Riser Card Bracket (Figure 6-15) 1. Disconnect the power supply and lay the chassis on a fl at surface. 2. Pull the motherboard node drawer from the chassis. 3.
  • Page 95: Installing Add-On And Riser Cards Onto The Motherboard

    Chapter 6: Advanced Chassis Setup Installing Add-On and Riser Cards onto the Motherboard Installing Expander and Riser Cards (Figure 6-16) 1. Disconnect the chassis from any power source. 2. Attach the riser card to the riser card bracket as described in the previous section.
  • Page 96: 6-11 Installing And Removing Hard Drives

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL 6-11 Installing and Removing Hard Drives The SC827HD chassis contains two individual motherboards in separate node drawers. Each motherboard node controls a set of six hard drives. Note that if a motherboard node drawer is pulled out of the chassis, the hard drives associated with that node will power down as well.
  • Page 97 Chapter 6: Advanced Chassis Setup Removing Hard Drive Carriers From the Chassis (Figure 6-18) 1. Press the release button on the drive carrier. This extends the drive bay handle. 2. Use the handle to pull the drive out of the chassis. Figure 6-18: Removing a Hard Drive Carrier 6-19...
  • Page 98 These carriers also help promote proper airfl ow for the drive bays. Caution! Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/files/ storage/SAS-CompList.pdf...
  • Page 99: 6-12 Power Supply

    Replacement units can be ordered directly from Supermicro (See the contact information in the Preface of this manual). Power Supply Replacement Changing the Power Supply (Figure 6-20) 1.
  • Page 100 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Figure 6-20: Changing the Power Supply Release Tab 6-22...
  • Page 101: Chapter 7 Bios

    When an option is selected in the left frame, it is highlighted in white. Often a text message will accompany it. (Note: the AMI BIOS has default text messages built in. Supermicro retains the option to include, omit, or change any of these text messages.) The AMI BIOS Setup Utility uses a key-based navigation system called "hot keys".
  • Page 102: Starting The Setup Utility

    Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update. If you have to update the BIOS, do not shut down or reset the system while the BIOS is updating.
  • Page 103 Chapter 7: BIOS Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks.
  • Page 104 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL CPU Confi guration This submenu displays the information of the CPU as detected by the BIOS. It also allows the user to confi guration CPU settings. Socket 1 CPU Information/Socket 2 CPU Information This submenu displays the following information regarding the CPU installed in Socket 1 and (or) Socket 2 as detected by the BIOS.
  • Page 105 Chapter 7: BIOS Active Processor Cores Set to Enabled to use a processor's second core and above. (Please refer to Intel's website for more information.) The options are All, 1, 2, 4, and 6. Limit CPUID Maximum Use this feature to set the maximum CPU ID value. Select Enabled to boot a legacy operating system that cannot support processors with extended CPUID functions.
  • Page 106 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Intel® Virtualization Technology (Available when supported by the CPU) Select Enabled to support Intel Virtualization Technology, which will allow one platform to run multiple operating systems and applications in independent partitions, creating multiple "virtual" systems in one physical computer. The options are Enabled and Disabled.
  • Page 107: North Bridge

    Chapter 7: BIOS Chipset Confi guration North Bridge This feature allows the user to confi gure the following North Bridge settings. Integrated IO Confi guration Intel VT-d Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to the VMM (Virtual Working Memory) through the DMAR ACPI Tables.
  • Page 108 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Port 1B Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for Port 1B. Select GEN2 to enable PCI-Exp Generation 2 support for Port 1B. Select GEN3 to enable PCI- Exp Generation 3 support for Port 1B. The options are GEN1, GEN2, and GEN3. IOU2-PCIe Port If this feature allows the user to set the bus speed between the IOU2 and the PCI-Exp port.
  • Page 109 Chapter 7: BIOS IOU3-PCIe Port If this feature allows the user to set the bus speed between the IOU3 and the PCI-Exp port. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, and x16. Port 3A Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for Port 3A. Select GEN2 to enable PCI-Exp Generation 2 support for Port 3A.
  • Page 110 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL DIMM Confi guration This item displays the following information of a DIMM module specifi ed by the user. CPU Socket 1 DIMM Information This item displays the memory type/speed of a memory module specifi ed. • P1-DIMMA1 •...
  • Page 111 Chapter 7: BIOS Rank Interleaving This feature allows the user to select a rank memory interleaving method. The options are Auto, 1 Way, 2 Way, 4, Way, and 8 Way. Patrol Scrub Patrol Scrubbing is a process that allows the CPU to correct correctable memory errors detected on a memory module and send the correction to the requestor (the original source).
  • Page 112 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL South Bridge Confi guration This feature allows the user to confi gure the settings for the Intel PCH chip. PCH Information This feature displays the following PCH information. Name: This item displays the name of the PCH chip. Stepping: This item displays the status of the PCH stepping.
  • Page 113 Chapter 7: BIOS SATA Confi guration When this submenu is selected, the AMI BIOS automatically detects the presence of IDE or SATA devices and displays the following items. SATA Port0~SATA Port5: The AMI BIOS displays the status of each SATA port as detected by the BIOS.
  • Page 114 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Port 0~5 Hot Plug Select Enabled to enable hot-plug support for a particular port, which will allow the user to change a hardware component or device without shutting down the system. The options are Enabled and Disabled. Staggered Spin Up Select Enabled to enable Staggered Spin-up support to prevent excessive power consumption caused by multiple HDDs spinning-up simultaneously.
  • Page 115 Chapter 7: BIOS PCIe/PCI/PnP Confi guration PCI ROM Priority Use this feature to select the Option ROM to boot the system when there are multiple Option ROMs available in the system. The options are EFI Compatible ROM and Legacy ROM. PCI Latency Timer Use this feature to set the latency Timer of each PCI device installed on a PCI bus.
  • Page 116 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Caution: Enabling ASPM support may cause some PCI-E devices to fail! SXB1 PCI-E 3.0 x16 Option ROM Select Enabled to enable CPU1 SXB1 PCI-E 3.0 x16 Option ROM to boot the system via a device installed on this slot. The options are Disabled and Enabled. SXB3 PCI-E 3.0 x16 Option ROM Select Enabled to enable CPU2 SXB3 PCI-E 3.0 x16 Option ROM to boot the system via a device installed on this slot.
  • Page 117: Serial Port Console Redirection

    Chapter 7: BIOS Super IO Confi guration Super IO Chip: This item displays the name of the super IO chip used in the system. COM1 Confi guration Serial Port Select Enabled to enable a serial port specifi ed. The options are Enabled and Disabled.
  • Page 118: Console Redirection Settings

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user. Serial Port for Out-of-Band Management/Windows Emergency Management Services (EMS) The submenu allows the user to confi...
  • Page 119 Chapter 7: BIOS Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd.
  • Page 120 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback, reducing the dependency on other timestamp calculation devices, such as an x86 RDTSC Instruction embedded in the CPU.
  • Page 121: Event Logs

    Chapter 7: BIOS Port Confi guration Information This section displays the following LAN Port settings. • UEFI Drive • Adapter PBA • Chip Type • PCI Device ID • PCI Bus: Device: Function • Link Status • Factory MAC Address •...
  • Page 122 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Erasing Settings Erase Event Log Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which is completed before a event logging is initialized upon system reboot. The options are No, Yes Next Reset, and Yes Every Reset. When Log is Full Select Erase Immediately to immediately erase SMBIOS error event logs that exceed the limit when the SMBIOS event log is full.
  • Page 123: Ipmi

    Chapter 7: BIOS IPMI Use this feature to confi gure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware Revision This item indicates the IPMI fi rmware revision used in your system. IPMI Status This item indicates the status of the IPMI fi rmware installed in your system. System Event Log Enabling/Disabling Options SEL Components...
  • Page 124 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL BMC Network Confi guration LAN Channel 1: This feature allows the user to confi gure the settings for LAN1 Port. Update IPMI LAN Confi guration This feature allows the user to decide if the BIOS should confi gure the IPMI setting at next system boot.
  • Page 125: Boot

    Chapter 7: BIOS Boot This submenu allows the user to confi gure the following boot settings for the system. CSM Support Select Enabled to enable UEFI Compatibility Support Module (CSM) to provide compatibility support to a traditional legacy BIOS which will allow an OS that requires CSM support to boot from a traditional option ROM.
  • Page 126: Security

    SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Security This menu allows the user to confi gure the following security settings for the system. Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility. The length of the password should be from 3-character to 8-character long.
  • Page 127 Chapter 7: BIOS Discard Changes Select this feature and press <Enter> to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previous values, click Yes to load the values previous saved, or click No to keep the changes you've made so far.
  • Page 128 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Notes 7-28...
  • Page 129: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 130 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Notes...
  • Page 131: Appendix B System Specifi Cations

    512 MB, 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB size sizes of 1.5V or 1.35V voltages. Note: refer to Section 5-6 for details on installation. Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information. SAS Drive Bays The SuperServer 6027TR-D71RF/D71QRF/D71FRF contains twelve (12) 3.5...
  • Page 132 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL Chassis SC827HD-R1K28B (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 28.5 in. (438 x 88 x 724 mm) Weight Gross (Bare Bone): 85 lbs. (38.6 kg.) System Cooling The SuperServer 6027TR-D71RF/D71QRF/D71FRF has four (4) 8-cm PWM system cooling fans System Input Requirements AC Input Voltage: 85-264V AC auto-range...
  • Page 133 Appendix B: System Specifi cations Notes...
  • Page 134 SUPERSERVER 6027TR-D71RF/D71QRF/D71FRF USER'S MANUAL (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...