USER'S MANUAL
S
ERVER
1.0b
®

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro 6027AX-TRF-HFT2

  • Page 1 UPER ® UPER ERVER 6027AX-TRF-HFT1 6027AX-TRF-HFT2 6027AX-TRF-HFT3 6027AX-72RF-HFT1 6027AX-72RF-HFT2 6027AX-72RF-HFT3 USER’S MANUAL 1.0b...
  • Page 2 This product, including software and docu- mentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3: About This Manual

    Preface Preface About This Manual This manual is written for professional system integrators and PC technicians. It provides information for the installation and use of the SuperServer 6027AX-72RF/ TRF-HFT1/HFT2/HFT3. Installation and maintenance should be performed by experienced technicians only. Manual Organization Chapter 1: Introduction The fi...
  • Page 4 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2 User's Manual Chapter 5: Advanced Serverboard Setup Chapter 5 provides detailed information on the X9DAX-7F/iF-HFT serverboard, including the locations and functions of connections, headers and jumpers. Refer to this chapter when adding or removing processors or main memory and when reconfi...
  • Page 5 Preface Notes...
  • Page 6: Table Of Contents

    Server Chassis Features ................1-3 System Power ....................1-3 Hard Drive Subsystem ..................1-3 Front Control Panel ..................1-3 Cooling System ....................1-3 Contacting Supermicro ..................1-5 Chapter 2 Server Installation Overview ......................2-1 Unpacking the System ..................2-1 Preparing for Setup ..................2-1 Choosing a Setup Location ................
  • Page 7 Table of Contents Power button ....................3-1 UID Button (Unit Identifi ed Button) ..............3-1 Control Panel LEDs ..................3-2 NIC2 ........................ 3-2 NIC1 ........................ 3-2 Informational LED ................... 3-2 OLED Screen ....................3-3 Drive Carrier LEDs ..................3-3 Chapter 4 Standardized Warning Statements for AC Systems About Standardized Warning Statements ............
  • Page 8 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual DIMM Installation .................... 5-8 Adding PCI Add-On Cards ................5-12 Serverboard Details ..................5-13 X9DAX-7F/iF-HFT Quick Reference ............. 5-14 Connector Defi nitions ................... 5-16 Jumper Settings .................... 5-23 5-10 Onboard Indicators ..................5-26 5-11 SATA Ports ....................5-27 5-12 Installing Software ..................
  • Page 9: Chapter 1 Introduction

    Supermicro product manuals: http://www.supermicro.com/support/manuals/ • Product drivers and utilities: ftp://ftp.supermicro.com • If you have any questions, please contact our support team at support@su- permicro.com Note: a complete list of safety warnings is provided on the Supermicro web site at http://www.supermicro.com/about/policies/safety_information.cfm...
  • Page 10: Serverboard Features

    Intel Xeon Processor E5-2687WV2, Socket R (LGA 2011) Please refer to the serverboard description pages on our web site for a complete listing of supported processors (www.supermicro.com). Memory The X9DAX-7F/iF-HFT has 16 DIMM slots that can support up to 512 GB of RDIMM, ECC LRDIMM or up to 128 GB of Unbuffered (UDIMM) ECC/non-ECC UDIMM DDR3-1866/1600/1333/1066/800 MHz type memory.
  • Page 11: Pci Expansion Slots

    Chapter 1: Introduction PCI Expansion Slots The X9DAX-7F/iF-HFT has two PCI-Express 3.0 x16 slots, four PCI-E3.0 x8 slots and one PCI Express 3.0 x 4 in x8 slot. PCI slots are controlled by CPUs: both CPUs must be installed to utilize all slots. See Chapter 5 for details. Rear I/O Ports The color-coded I/O ports include one COM port, a VGA port, two USB 3.0 ports, four USB 2.0 ports (additional USB headers are included on the serverboard) and...
  • Page 12: System Block Diagram

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Figure 1-1. Intel C602 Chipset (PCH A): System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for details. #0-4 #1-4 #0-3 #1-3 #0-2 #1-2 #0-1 Intel E5-2600 Intel E5-2600 #1-1 8 SNB CORE 8 SNB CORE DDR3...
  • Page 13: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 14 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Notes...
  • Page 15: Chapter 2 Server Installation

    Chapter 2: Server Installation Chapter 2 Server Installation Overview This chapter provides a quick setup checklist to get your SuperServer 6027AX- 72RF/TRF-HFT1/HFT2/HFT3 up and running. Following these steps in the order given should enable you to have the system operational within a minimum amount of time.
  • Page 16: Rack Precautions

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual • This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets and the like). • This product is not suitable for use with visual display work place devices acccording to §2 of the the German Ordinance for Work with Visual Display Units.
  • Page 17: Rack Mounting Considerations

    Chapter 2: Server Installation Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (Tmra).
  • Page 18: Installing The System Into A Rack

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Installing the System into a Rack This section provides information on installing the SC8298 chassis into a rack unit with the quick-release rails provided. There are a variety of rack units on the market, which may mean the assembly procedure will differ slightly. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 19 Chapter 2: Server Installation Figure 2-1: Separating the Rack Rails Separating the Inner and Outer Rails Rail Assembly 1. Locate the rail assembly in the chassis packaging. 2. Extend the rail assembly by pulling it Extending the Rails outward. 3. Press the quick-release tab. 4.
  • Page 20: Outer Rack Rails

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Figure 2-2. Assembling the Outer Rails Outer Rack Rails Outer rails attach to the rack and hold the chassis in place. The outer rails for the SC825 chassis extend between 30 inches and 33 inches. Installing the Outer Rails to the Rack 1.
  • Page 21 Chapter 2: Server Installation Figure 2-3. Installing the Rack Rails Installing the Chassis into a Rack 1. Extend the outer rails as illustrated above. 2. Align the inner rails of the chassis with the outer rails on the rack. 3. Slide the inner rails into the outer rails, keeping the pressure even on both sides.
  • Page 22 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Notes...
  • Page 23: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview There are several LEDs on the control panel as well as others on the hard drive carriers to keep you constantly informed of the overall status of the system as well as the activity and health of specifi...
  • Page 24: Control Panel Leds

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Control Panel LEDs The control panel located on the front of the SC829BTQ chassis has fi ve LEDs. These LEDs provide you with critical information related to different parts of the system. This section explains what each LED indicates when illuminated and any corrective action you may need to take.
  • Page 25: Oled Screen

    12 characters per line, the OLED screen module displays vivid colors with 64 x 96 pixels and 16 bit color. More details are available on our web site at http://www.supermicro.com/lcd. Drive Carrier LEDs  Blue: Each hard drive carrier has a green LED. When illuminated, this green LED indicates drive activity.
  • Page 26 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Notes...
  • Page 27: Chapter 4 Standardized Warning Statements For Ac Systems

    The following statements are industry standard warnings, provided to warn the user of situations which have the potential for bodily injury. Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certifi ed technicians should attempt to install or confi gure components.
  • Page 28 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 29 Warning Statements for AC Systems ‫ﺟﺴﺪﻳﺔ‬ ‫ﺍﺻﺎﺑﺔ‬ ‫ﺗﺘﺴﺒﺐ ﻓﻲ‬ ‫ﺣﺎﻟﺔ ﻳﻤﻜﻦ ﺃﻥ‬ ‫ﺍﻧﻚ ﻓﻲ‬ ‫ﺧﻄﺮ‬ ‫ﻳﻌﻨﻲ‬ ‫ﻫﺬﺍ ﺍﻟﺮﻣﺰ‬ !‫ﺗﺤﺬﻳﺮ‬ ‫ﺍﻟﺪﻭﺍﺋﺮ‬ ‫ﺑﺎﻟﻤﺨﺎﻁﺮ ﺍﻟﻨﺎﺟﻤﺔ ﻋﻦ‬ ‫ﻦ ﻋﻠﻰ ﻋﻠﻢ‬ ، ‫ﻛ‬ ‫ﻣﻌﺪﺍﺕ‬ ‫ﺗﻌﻤﻞ ﻋﻠﻰ ﺃﻱ‬ ‫ﻗﺒﻞ ﺃﻥ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬ ‫ﺣﻮﺍﺩﺙ‬ ‫ﺃﻱ‬ ‫ﻭﻗﻮﻉ‬ ‫ﻤﻨﻊ‬ ‫ﻟ‬ ‫ﺍﻟﻮﻗﺎﺋﻴﺔ‬...
  • Page 30: Installation Instructions

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 31: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 32: Power Disconnection Warning

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록 해야 합니다. Waarschuwing Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van uw electrische installatie. Controleer of het beveiligde aparaat niet groter gedimensioneerd is dan 220V, 20A.
  • Page 33 Chapter 4: Warning Statements for AC Systems ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema. Attention Le système doit être débranché...
  • Page 34: Equipment Installation

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Equipment Installation Warning! Only trained and qualifi ed personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifi...
  • Page 35: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalifi ceerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 36: Battery Handling

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .('‫כלי אבטחה בלבד )מפתח, מנעול וכד‬ ‫ﻣﺤﻈﻮﺭﺓ‬ ‫ﻣﻨﺎﻁﻖ‬ ‫ﻟﺘﺮﻛﻴﺒﻬﺎ ﻓﻲ‬ ‫ﻫﺬﻩ ﺍﻟﻮﺣﺪﺓ‬ ‫ﺗﺨﺼﻴﺺ‬ ‫ﺗﻢ‬ ،‫ﺃﺩﺍﺓ ﺧﺎﺻﺔ‬ ‫ﻣﻦ ﺧﻼﻝ ﺍﺳﺘﺨﺪﺍﻡ‬ ‫ﻓﻘﻂ‬...
  • Page 37 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 38: Redundant Power Supplies

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 39: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫ﺍﻣﺪﺍﺩ ﺍﻟﻄﺎﻗﺔ‬ ‫ﺑﻮﺣﺪﺍﺕ‬ ‫ﻋﺪﺓ ﺍﺗﺼﺎﻻﺕ‬ ‫ﺠﻬﺎﺯ‬ ‫ﺍﻟ‬ ‫ﻳﻜﻮﻥ ﻟﻬﺬﺍ‬ ‫ﻗﺪ‬ ‫ﺍﻟﻜﻬﺮﺑﺎء‬ ‫ﻋﻦ‬ ‫ﻮﺣﺪﺓ‬ ‫ﺍﻟ‬ ‫ﻟﻌﺰﻝ‬ ‫ﻛﺎﻓﺔ ﺍﻻﺗﺼﺎﻻﺕ‬ ‫ﻳﺠﺐ ﺇﺯﺍﻟﺔ‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 40: Comply With Local And National Electrical Codes

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬ ‫ﺍﻟﻠﻮﺣﺔ‬ ‫ﺃﻭﺍﻟﻄﺎﻗﺔ ﺍﻟﻤﻮﺟﻮﺩﺓ ﻋﻠﻰ‬ ‫ﺍﻟﺘﻴﺎﺭ ﺍﻟﻜﻬﺮﺑﺎﺋﻲ‬ ‫ﻣﻦ‬ ‫ﺧﻄﺮ‬ ‫ﻫﻨﺎﻙ‬ ‫ﻫﺬﺍ ﺍﻟﺠﻬﺎﺯ‬ ‫ﺧﺪﻣﺔ‬ ‫ﻛﻦ ﺣﺬﺭﺍ ﻋﻨﺪ‬ ‫ﻳﻌﻤﻞ‬ ‫ﺍﻟﻨﻈﺎﻡ‬ ‫ﻋﻨﺪﻣﺎ ﻳﻜﻮﻥ‬ 경고! 시스템이...
  • Page 41: Product Disposal

    Chapter 4: Warning Statements for AC Systems Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬ ‫ﺍﻟﻤﺘﻌﻠﻘﺔ‬ ‫ﺍﻟﻤﺤﻠﻴﺔ ﻭﺍﻟﻮﻁﻨﻴﺔ‬ ‫ﻘﻮﺍﻧﻴﻦ‬ ‫ﻳﺠﺐ ﺃﻥ ﻳﻤﺘﺜﻞ ﻟﻠ‬ ‫ﺍﻟﻜﻬﺮﺑﺎﺋﻴﺔ‬...
  • Page 42: Hot Swap Fan Warning

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent.
  • Page 43 Chapter 4: Warning Statements for AC Systems 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 44: Power Cable And Ac Adapter

    fi re. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certifi ed cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター...
  • Page 45 Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifi és qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
  • Page 46 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Notes 4-20...
  • Page 47: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference. Remember to completely close the chassis when you have fi...
  • Page 48: Connecting Cables

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Connecting Cables Now that the serverboard is installed, the next step is to connect the cables to the board. These include the data cables for the peripherals and control panel and the power cables. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed to prevent them from blocking the fl...
  • Page 49: Rear I/O Ports

    Chapter 5: Advanced Serverboard Setup Figure 5-1. Control Panel Header Pins Ground 3.3 V FP PWRLED HDD LED ID_UID_SW/3/3V Stby NIC1 Link LED NIC1 Activity LED NIC2 Activity LED NIC2 Link LED Blue+ (OH/Fan Fail/ Red+ (Blue LED Cathode) PWR FaiL/UID LED) Power Fail LED 3.3V Reset...
  • Page 50: Installing The Processor And Heatsink

    CPU socket cap is in place and none of the socket pins are bent; otherwise, contact your retailer immediately. • Refer to the Supermicro web site for updates on CPU support. Installing an Xeon E5-2600 Processor Press down on the lever labeled 'Close 1st' 1.
  • Page 51 Chapter 5: Advanced Serverboard Setup 3. With the lever labeled 'Close 1st' fully retracted, gently push down on the 'Open 1st' lever to open the load plate. Lift the load plate to open it completely. Gently push 4. Using your thumb and the index down to pop the load plate fi...
  • Page 52 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Caution: You can only install the CPU to the socket in one direction. Make sure that the CPU is properly inserted into the socket before closing the load plate. If it doesn't close properly, do not force it as it may damage your CPU. Instead, open the load plate again and double-check that the CPU is aligned properly.
  • Page 53: Installing A Passive Cpu Heatsink

    Chapter 5: Advanced Serverboard Setup Installing a Passive CPU Heatsink 1. Do not apply any thermal grease to the heatsink or the CPU die -- the re- quired amount has already been applied. 2. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the serverboard and the heatsink bracket underneath.
  • Page 54: Installing Memory

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Installing Memory Caution! Exercise extreme care when installing or removing DIMM modules to prevent any possible damage. Memory Support The X9DAX-7F/iF-HFT supports up to 512 GB of DDR3 Registered(RDIMM)/Load Reduced (LRDIMM) ECC or up to 128 GB of Unbuffered (UDIMM) ECC/Non-ECC 1600/1333/1066/800 MHz 4-channel memory modules in 16 DIMM slots.
  • Page 55 Chapter 5: Advanced Serverboard Setup DIMM Module Population Table Follow the tables below when installing memory. Processors and their Corresponding Memory Modules CPU# Corresponding DIMM Modules CPU 1 DIMMA1 DIMMB1 DIMMC1 DIMMD1 DIMMA2 DIMMB2 DIMMC2 DIMMD2 CPU2 DIMME1 DIMMF1 DIMMG1 DIMMH1 DIMME2 DIMM F2...
  • Page 56 1333 1333 1333 Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm. Populating RDIMM (ECC) Memory Modules Intel E5-2600 Series Processor RDIMM Memory Support Ranks Memory Capacity...
  • Page 57 1333 Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro. com/support/resources/mem.cfm. Other Important Notes and Restrictions • For the memory modules to work properly, please install DIMM modules of the same type, same speed and same operating frequency.
  • Page 58: Adding Pci Add-On Cards

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Adding PCI Add-On Cards The 6027AX-72RF/TRF-HFT1/HFT2/HFT3 can accommodate up to six low-profi le add-on (expansion) cards. Installing an Add-on Card 1. Begin by removing the shield for the PCI slot you wish to populate. 2. Fully seat the card into the slot, pushing down with your thumbs evenly on both sides of the card.
  • Page 59: Serverboard Details

    Chapter 5: Advanced Serverboard Setup Serverboard Details Figure 5-5. X9DAX-7F/iF-HFT Layout JAUDIO1 JVGA USB3.0_0/1 LAN1 LAN2 AUDIO FP HD AUDIO CTRL USB2.0_0~3 IPMI_LAN JLAN2 JLAN1 Audio CTRL Processor Battery BIOS X9DAX-7F/iF-HFT Rev. 1.02 Intel CTRL Processor L-SAS0~3 L-SAS4~7 FAN4 JPS1 FAN3 I-SATA2 Notes...
  • Page 60: X9Dax-7F/If-Hft Quick Reference

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual X9DAX-7F/iF-HFT Quick Reference Jumper Description Default Setting J29/J30 SMB Enable Pins 1-2 (Enabled) JCMOS1 Clear CMOS Open (Normal) C1/JI SMBus to PCI-E Slots Pins 2-3 (Normal) JPB1 BMC Enable Pins 1-2 (Enabled) JPG1 VGA Enable Pins 1-2 (Enabled) JPI1 IEEE1394a Enable...
  • Page 61 Chapter 5: Advanced Serverboard Setup (I-)SATA0~5 Intel SB SATA Connectors 0~5 (SATA 0/1: SATA 3.0 Ports, SATA2~5: SATA 2.0 ports) (S-)SATA0~3 SATA 2.0 Connectors 0~3 from SCU (Storage Control Unit) (CPU1) Slot1/Slot2 PCI-E 3.0 x16 Slots (Available when CPU1 is installed.) (CPU2) Slots 3/5/6/7 PCI-E 3.0 x8 Slot (Available when CPU2 is installed.) (PCH) Slot4...
  • Page 62: Connector Defi Nitions

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Connector Defi nitions Power Connectors ATX Power 24-pin Connector Pin Defi nitions A 24-pin main power supply connector(JPW1) Pin# Defi nition Pin # Defi nition and two 8-pin CPU PWR connectors +3.3V +3.3V (JPW2/2) are located on the motherboard. -12V +3.3V These power connectors meet the SSI EPS...
  • Page 63 Chapter 5: Advanced Serverboard Setup Power Fail LED PWR Fail LED Pin Defi nitions (JF1) The Power Fail LED connection is lo- Pin# Defi nition cated on pins 5 and 6 of JF1. See the 3.3V table on the right for pin defi nitions. PWR Supply Fail Overheat (OH)/Fan Fail/PWR Fail/ OH/Fan Fail/ PWR Fail/Blue_...
  • Page 64 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Power On LED Power LED Pin Defi nitions (JF1) The Power On LED connector is lo- Pin# Defi nition cated on pins 15 and 16 of JF1 (use 5V Stby JLED for a 3-pin connector). This Control connection is used to provide LED indication of power being supplied to...
  • Page 65 Chapter 5: Advanced Serverboard Setup LAN Ports Ethernet Ports Pin Defi nition Two Ethernet ports are located on the Pin# Defi nition I/O backplane. A dedicated IPMI LAN P2V5SB SGND port is also included to provide KVM TD0+ Act LED support for IPMI 2.0.
  • Page 66 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Internal Buzzer (SP1) Pin Defi nition Pin# Defi nitions Pin 1 Pos. (+) Beep In Internal Speaker Pin 2 Neg. (-) Alarm The internal speaker, located at SP1, Speaker can be used to provide audible indica- tions for various beep codes.
  • Page 67 Chapter 5: Advanced Serverboard Setup TPM Header/Port 80 TPM/Port 80 Header Pin Defi nitions A Trusted Platform Module/Port 80 Pin # Defi nition Pin # Defi nition header is located at JTPM1 to provide LCLK TPM support and a Port 80 connec- LFRAME# <(KEY)>...
  • Page 68 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Standby Power Header Standby PWR Pin Defi nitions The +5V Standby Power header is lo- Pin# Defi nition cated at JSTBY1. See the table on the +5V Standby right for pin defi nitions. (You must also Ground have a card with a Standby Power con- Wake-up...
  • Page 69: Jumper Settings

    Chapter 5: Advanced Serverboard Setup Jumper Settings Explanation of Jumpers To modify the operation of the serverboard, jumpers can be used Connector to choose between optional settings. Pins Jumpers create shorts between two pins to change the function of the con- nector.
  • Page 70 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Watch Dog Enable/Disable Watch Dog Jumper Settings Watch Dog (JWD1) is a system monitor that Jumper Setting Defi nition can reboot the system when a software ap- Pins 1-2 Reset (default) plication hangs. Close Pins 1-2 to reset the Pins 2-3 system if an application hangs.
  • Page 71 Chapter 5: Advanced Serverboard Setup VGA Enable VGA Enable Jumper Settings Jumper JPG1 allows the user to enable Jumper Setting Defi nition the onboard VGA connector. The default Enabled (Default) Pins 1-2 setting is Pins 1-2 to enable the con- Disabled Pins 2-3 nection.
  • Page 72: 5-10 Onboard Indicators

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual 5-10 Onboard Indicators Activity LED Link LED GLAN LEDs Rear View (when facing the rear side of the chassis) Two LAN ports (LAN 1/LAN 2) are located on the IO Backplane of the motherboard. Each Ethernet LAN port has two LEDs. LAN 1/LAN 2 Activity LED (Right) LED State The green LED indicates activity, while the...
  • Page 73: 5-11 Sata Ports

    Parallel ATA. RX_N See the table on the right for pin defi nitions. RX_P Ground Note: For more information on HostRAID confi guration, please refer to the HostRAID User's Guide posted on our Website @ http://www.supermicro. com. 5-27...
  • Page 74: 5-12 Installing Software

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO fi...
  • Page 75: Superdoctor Iii

    Chapter 5: Advanced Serverboard Setup SuperDoctor III The SuperDoctor® III program is a web-based management tool that supports remote management capability. It includes Remote and Local Management tools. The local management is called SD III Client. The SuperDoctor III program allows you to monitor the environment and operations of your system.
  • Page 76 ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Figure 5-8. SuperDoctor III Interface Display Screen (Remote Control) Note: The SuperDoctor III program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/accessories/soft- ware/SuperDoctorIII.cfm. For Linux, we recommend that you use the SuperDoctor II application instead.
  • Page 77: 5-13 Onboard Battery

    Chapter 5: Advanced Serverboard Setup 5-13 Onboard Battery Serverboard Battery: CAUTION - There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 4-1). This battery must be replaced only with the same or an equivalent type recom- mended by the manufacturer (CR2032).
  • Page 78: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform mainte- nance on the SC829BTQ-R1K28LPB chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the next step.
  • Page 79: Control Panel

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Figure 6-1. Chassis: Front View Control Panel LCD Screen Hard Drive Bays (10) 6027AX-72RF Drive Confi guration SAS2 SAS5 SAS1 SAS4 SAS7 SATA1 SAS0 SAS3 SAS6 SATA0 6027AX-TRF Drive Confi guration SATA2 (ISATA2) SATA5 (SSATA1) SATA1 (ISATA1) SATA4 (SSATA0) SAS7 (SSATA3)
  • Page 80: Accessing The Inside Of The System

    Chapter 6: Advanced Chassis Setup Accessing the Inside of the System 1. If rack mounted, fi rst, grasp the two handles on either side and pull the sys- tem straight out until it locks (you will hear a "click"). 2. Remove the two screws on each side of the cover, which secure the cover to the chassis.
  • Page 81: System Fans

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual System Fans The SC829BTQ chassis contains four 8-cm high-performance fans. System Fan Failure Fan speed is controlled by system temperature via IPMI. If a fan fails, the remaining fan will ramp up to full speed and the overheat/fan fail LED on the control panel will turn on.
  • Page 82: Accessing The Drive Bays

    Chapter 6: Advanced Chassis Setup Figure 6-3. System Fans Accessing the Drive Bays Hard Drives: Because of their hot-swap capability, you do not need to access the inside of the chassis or power down the system to install or replace the hard drives. Proceed to the next section for instructions.
  • Page 83: Hard Drive Installation

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Hard Drive Installation The SC829B chassis accepts ten hot-swappable 3.5" hard drives. The hard drives are mounted in drive carriers to simplify their installation and removal from the chassis. System power may remain on when removing carriers with drives installed. These carriers also help promote proper airfl...
  • Page 84 Chapter 6: Advanced Chassis Setup Installing a Hard Drive into a Drive Carrier 1. Remove the screws securing the dummy drive to the carrier. 2. Remove the dummy drive from the carrier. 3. Install a new drive into the carrier with the printed circuit board side facing down so that the mounting holes align with those in the carrier.
  • Page 85 Figure 6-6. Installing a Hard Drive Figure 6-7. Installing a Carrier into its Bay Warning! Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/ storage.cfm...
  • Page 86: Power Supply

    The PWR Fail LED will illuminate and remain on until the failed unit has been replaced. Replace- ment units can be ordered directly from Supermicro. The power supply units have a hot-swap capability, meaning you can replace the failed unit without powering down the system.
  • Page 87: Chapter 7 Bios

    Chapter 7: AMI BIOS Chapter 7 BIOS Introduction This chapter describes the AMI BIOS Setup utility for the X9DAX-7F/-iF. It also provides the instructions on how to navigate the AMI BIOS Setup utility screens. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. Starting BIOS Setup Utility To enter the AMI BIOS Setup utility screens, press the <Del>...
  • Page 88: How To Change The Confi Guration Data

    <Delete> at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Re- covery User Guide posted @http://www.supermicro.com/support/manuals/. Starting the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test.
  • Page 89 This item displays the system date in Day MM/DD/YY format (e.g. Wed 10/12/2012). System Time This item displays the system time in HH:MM:SS format (e.g. 15:32:52). Supermicro X9DAX SMC Version This item displays the SMC version of the BIOS ROM used in this system.
  • Page 90: Advanced Setup Confi Gurations

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Advanced Setup Confi gurations Use the arrow keys to select Advanced Setup and press <Enter> to access the following submenu items. Boot Features Quiet Boot This feature allows the user to select bootup screen display between POST mes- sages and the OEM logo.
  • Page 91 Chapter 7: AMI BIOS Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks.
  • Page 92 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual • Microcode Patch • CPU Stepping • Max/Min CPU Speed • Processor Cores • Intel HT (Hyper-Threading) Technology • Intel VT-x Technology • Intel SMX Technology • L1 Data Cache • L1 Code Cache • L2 Cache/L3 Cache CPU Speed This item displays the speed of the CPU installed in the Socket selected.
  • Page 93 Chapter 7: AMI BIOS and where it cannot, thus preventing a worm or a virus from fl ooding illegal codes to overwhelm the processor or damage the system during an attack. The default is Enabled. (Refer to Intel and Microsoft Web sites for more information.) Hardware Prefetcher (Available when supported by the CPU) If set to Enabled, the hardware prefetcher will prefetch streams of data and instruc- tions from the main memory to the L2 cache to improve CPU performance.
  • Page 94 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual  CPU Power Management Confi guration This submenu allows the user to confi gure the following CPU Power Manage- ment settings. Power Technology Select Energy Effi cient to support power-saving mode. Select Custom to cus- tomize system power settings.
  • Page 95 Chapter 7: AMI BIOS CPU C7 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C7 State (ACPI C3) to the operating system. CPU C7 State is a processor-specifi c low C-State. The options are Enabled and Disabled.
  • Page 96: North Bridge

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Chipset Confi guration North Bridge This feature allows the user to confi gure the settings for the Intel North Bridge. IOH Confi guration Intel VT-d Select Enabled to enable Intel Virtualization Technology support for Direct I/O VT-d by reporting the I/O device assignments to the VMM (Virtual Machine Monitor) through the DMAR ACPI Tables.
  • Page 97 Chapter 7: AMI BIOS IOU2 - PCIe Port This feature allows the user to set the PCI-Exp bus speed between IOU2 and the PCI-e port. The options are x4x4x4x4, x4x4x8, x8x4x4, x8x8, and x16. Port 2A Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for Port 2A. Select GEN2 to enable PCI-Exp Generation 2 support for Port 2A.
  • Page 98 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Port 2A Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for Port 2A. Select GEN2 to enable PCI-Exp Generation 2 support for Port 2A. Select GEN3 to enable PCI-Exp Generation 3 support for Port 2A. The options are GEN1, GEN2, and GEN3.
  • Page 99 Chapter 7: AMI BIOS Use this feature to select the desired QPI frequency. The options are Auto, 6.4 GT/s, 7.2 GT/s, and 8.0 GT/s. DIMM Confi guration This section displays the following DIMM information. Current Memory Mode This item displays the current memory mode. Current Memory Speed This item displays the current memory speed.
  • Page 100 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Select Unhide to display the Perfmon and DXF devices installed in the system. The options are HIDE and UNHIDE. DRAM RAPL Mode RAPL (Running Average Power Limit) provides mechanisms to enforce power consumption limits on supported processors The options are DRAM RAPL MODE0 , DRAM RAPL MODE1, and Disabled.
  • Page 101 Chapter 7: AMI BIOS DRAM RAPL (Running Average Power Limit) This item allows the user to select the average power limit setting when a DRAM module is in operation. The options are Disabled, Mode 0, and Mode 1. Device Tagging Select Enabled to support device tagging.
  • Page 102 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Port 60/64 Emulation Select Enabled to enable I/O port 60h/64h emulation support for the legacy USB keyboard so that it can be fully supported by the operating systems that does not recognize a USB device. The options are Disabled and Enabled. EHCI Hand-Off This item is for operating systems that do not support Enhanced Host Controller Interface (EHCI) hand-off.
  • Page 103 Chapter 7: AMI BIOS AHCI Mode The following items are displayed when the AHCI Mode is selected. Aggressive Link Power Management When Enabled, the SATA AHCI controller manages the power usage of the SATA link. The controller will put the link in a low power mode during extended periods of I/O inactivity, and will return the link to an active state when I/O activity resumes.
  • Page 104 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual PCIe/PCI/PnP Confi guration PCI ROM Priority Use this feature to select the Option ROM to boot the system when there are mul- tiple Option ROMs available in the system. The options are EFI Compatible ROM and Legacy ROM.
  • Page 105: Serial Port Console Redirection

    Chapter 7: AMI BIOS the system. Select Disabled to disable ASPM support. The options are Disabled, Force L0s, and Auto. Warning: Enabling ASPM support may cause some PCI-E devices to fail! Slot 1, 2, 3, 4, 5, 6, 7 OPROM Select Enabled to enable Option ROM support to boot the computer using a de- vice installed on the slots specifi...
  • Page 106: Console Redirection Settings

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled. Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer, which is the remote computer used by the user.
  • Page 107 Chapter 7: AMI BIOS Flow Control This feature allows the user to set the fl ow control for Console Redirection to prevent data loss caused by buffer overfl ow. Send a "Stop" signal to stop send- ing data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty.
  • Page 108: Acpi Settings

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Out-of-Band Management Port The feature selects a serial port used by the Microsoft Windows Emergency Management Services (EMS) to communicate with a remote server. The default setting is COM1. Terminal Type This feature allows the user to select the target terminal emulation type for Con- sole Redirection.
  • Page 109 Chapter 7: AMI BIOS NUMA (NON-Uniform Memory Access) This feature enables the Non-Uniform Memory Access ACPI support. The options are Enabled and Disabled. High Precision Event Timer Select Enabled to activate the High Precision Event Timer (HPET) that produces periodic interrupts at a much higher frequency than a Real-time Clock (RTC) does in synchronizing multimedia streams, providing smooth playback, reducing the de- pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc- tion embedded in the CPU.
  • Page 110: Overclocking

    TPM Support: Trusted Platform support TPM State: Trusted Platform state Overclocking Use this submenu to override selected CPU voltage settings. Warning: Overclocking may cause system instability and is not recom- mended by Supermicro for standard use of the product. 7-24...
  • Page 111 Chapter 7: AMI BIOS CPU Voltage Use this feature to override the CPU Voltage settings specifi ed by the manufacturer. The VID+Offset options range from 0m Volts to 500m Volts. CPU BCLK Use this feature to override the CPU BCLK (Base Clock) settings specifi ed by the manufacturer.
  • Page 112: Event Logs

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Force DDR3-1066, Force DDR3-1333, Force DDR3-1600, Force DDR3 1866, and Force SPD. tCL, tRCD, tRP Use the above items to set the tCL (Cas Latency), tRCD (Row to Col Delay), and Ras Precharge values. The options are Auto, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, and 18.
  • Page 113: Change Smbios Event Log Settings

    Chapter 7: AMI BIOS  Change SMBIOS Event Log Settings This feature allows the user to confi gure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot. The options are Enabled and Disabled. Runtime Error Logging Support Select Enabled to support Runtime Error Logging.
  • Page 114: Ipmi

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which is completed before an event logging is initialized upon system reboot. The options are No, Yes, next reset, and Yes, every reset. When Log is Full Select Erase Immediately to immediately erase SMBIOS error event logs that ex- ceed the limit when the SMBIOS event log is full.
  • Page 115: System Event Log

    Chapter 7: AMI BIOS IPMI Firmware Revision This item indicates the IPMI fi rmware revision used in your system. IPMI Status This item indicates the status of the IPMI fi rmware installed in your system.  System Event Log Enabling/Disabling Options SEL Components Select Enabled for all system event logging at bootup.
  • Page 116 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full.
  • Page 117: Boot

    Chapter 7: AMI BIOS Gateway IP Address This item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). Boot This submenu allows the user to confi gure the following boot settings for the system.
  • Page 118: Security

    UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Security This menu allows the user to confi gure the following security settings for the system. Administrator Password Use this feature to set the Administrator Password which is required to enter the BIOS setup utility. The length of the password should be from 3 characters to 20 characters long.
  • Page 119: Save & Exit

    Chapter 7: AMI BIOS Save & Exit This submenu allows the user to confi gure the Save and Exit settings for the system. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system confi...
  • Page 120 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Discard Changes Select this feature and press <Enter> to discard all the changes and return to the BIOS setup. When the dialog box appears, asking you if you want to load previ- ous values, select Yes to load the values previous saved, or select No to keep the changes you've made so far.
  • Page 121: Appendix A Bios Error Beep Codes

    Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each system boot, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue to boot.
  • Page 122 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual Notes...
  • Page 123: Appendix B System Specifi Cations

    Appendix B: System Specifi cations Appendix B System Specifi cations Processors Dual Intel® Xeon® processors E5-2687W (“HFT1”), E5-2643 (“HFT2”) or E5- 2687WV2 (“HFT3”); Socket R (LGA 2011) Note: Please refer to our web site for a complete listing of supported processors. Chipset Intel®...
  • Page 124 UPER ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual System Cooling Four 8-cm system cooling fans System Input Requirements AC Input Voltage: 100 - 240V AC auto-range Rated Input Current: 9 - 3.5A max Rated Input Frequency: 50 to 60 Hz Power Supply Rated Output Power: 1280W (Part# PWS-1K28P-1R) Rated Output Voltages: +12V (106.7A), +5Vsb (4A) Operating Environment Operating Temperature: 10º...
  • Page 125 Appendix B: System Specifi cations Notes...
  • Page 126 ERVER 6027AX-72RF/TRF-HFT1/HFT2/HFT3 User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency com- munication devices or other critical systems whose failure to perform be reasonably expected to result in signifi...