Table of Contents

Advertisement

Quick Links

S
UPER
®
S
S
UPER
ERVER
®
6027PR-HTR
6027PR-HTTR
6027PR-HTFR
USER'S MANUAL
Revision 1.0

Advertisement

Table of Contents
loading

Summary of Contents for Supermicro SUPER SUPERSERVER 6027PR-HTR

  • Page 1 UPER ® UPER ERVER ® 6027PR-HTR 6027PR-HTTR 6027PR-HTFR USER’S MANUAL Revision 1.0...
  • Page 2 This product, including software and documentation, is the property of Supermicro and/or its licensors, and is supplied only under a license. Any use or reproduction of this product is not allowed, except as expressly permitted by the terms of said license.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro Web site for possible updates to the manual revision level. Warnings Special attention should be given to the following symbols used in this manual.
  • Page 4: Table Of Contents

    : System Notes ................. 1-7 Nodes ......................1-7 System Power ....................1-7 SATA Backplane/Drives ................... 1-7 Contacting Supermicro ..................1-8 Chapter 2 Rack Installation ..............2-1 Unpacking the System ..................2-1 Preparing for Setup ..................2-1 Choosing a Setup Location ................2-1 Warnings and Precautions ................
  • Page 5 Preface Circuit Overloading ..................2-3 Reliable Ground ..................2-3 Installing the System into a Rack ..............2-4 Identifying the Sections of the Rack Rails ............2-4 Releasing the Inner Rail ................. 2-5 Installing the Inner Rails on the Chassis ............2-6 Installing the Outer Rails onto the Rack ............
  • Page 6 SUPERSERVER 6027PR-HT(R/TR/FR) Manual Installing the Processor and Heatsink ............5-3 Installing an LGA 2011 Processor ..............5-3 Installing a CPU Heatsink ................5-6 Removing the Heatsink .................. 5-6 Installing Memory .................... 5-7 Memory Support ....................5-7 Maximum Memory ................... 5-8 Adding PCI Expansion Cards ................5-11 Serverboard Details ..................
  • Page 7 Preface Chapter 7 BIOS ..................7-1 Starting BIOS Setup Utility ................7-1 How To Change the Configuration Data ............7-1 Starting the Setup Utility ................. 7-2 Main Setup ...................... 7-2 Advanced Setup Configurations..............7-4 Event Logs ....................7-28 IPMI ....................... 7-30 Boot .......................
  • Page 8 SUPERSERVER 6027PR-HT(R/TR/FR) Manual Notes...
  • Page 9: Chapter 1 Introduction

    Note: For your system to work properly, please follow the links below to download all necessary drivers/utilities and the user’s manual for your server. • Product manuals: http://www.supermicro.com/support/manuals/ • Product drivers and utilities: ftp://ftp.supermicro.com • Product safety information: http://super-dev/about/policies/safety_information.cfm If you have any questions, contact support@supermicro.com.
  • Page 10: Serverboard Features

    The 6027PR-HTTR uses the X9DRT-PT serverboard with 10Gb network speed. • The 6027PR-HTFR uses the X9DRT-PIBF serverboard with Infiniband. The sections below cover the main features. Refer to the Supermicro web site for updated specifications and details. (see Figure 1-1 for a block diagram). Processors Each serverboard supports single or dual Intel Xeon E5-2600 series processors (Socket R LGA 2011).
  • Page 11: Onboard Controllers

    Chapter 1: Introduction Onboard Controllers Each serverboard includes: IPMI: Support for Intelligent Platform Management Interface v.2.0 with virtual media over LAN and KVM-over-LAN support. Nuvoton WPCM450 BMC Network Controllers: • For 6027PR-HTR and 6027PR-HTFR, Intel i350 dual port Gigabit Ethernet •...
  • Page 12: Server Chassis Features

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Server Chassis Features The SC827HQ+ is an proprietary form factor chassis designed to be used in a 2U rackmount configuration. The following is a general outline of the main features. System Power The chassis includes dual high-efficiency 80-plus Platinum certified hot-plug power supply modules, rated at 2000 Watts.
  • Page 13: Advanced Power Management

    Chapter 1: Introduction Advanced Power Management Intel Intelligent Power Node Manager The Intel Intelligent Power Node Manager (IPNM) provides your system with real-time thermal control and power management for maximum energy efficiency. Although IPNM Specification Version 1.5 is supported by the BMC (Baseboard Management Controller), your system must also have IPNM-compatible Manageability Engine (ME) firmware installed to use this feature.
  • Page 14 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Gen3 x8 Gen3 x16 CPU FRONT FAN Side Socket 1 E5-2600 Series Processor CPU REAR (I/O Side) Socket 0 E5-2600 Series Processor Gen3 Gen3 Gen3 3/1.5 SATA3 #6 3/1.5 SATA3 #5 x8(8..15) 3/1.5 SATA2 #4 QSFP 3/1.5 SATA2 #3 x8(0..7)
  • Page 15: Twin 2 : System Notes

    Chapter 1: Introduction 2U Twin : System Notes As a 2U Twin configuration, the SuperServer 6027PR-HT(R/TR/FR) is a unique server system. With four system boards incorporated into a single chassis acting as four separate nodes, there are several points you should keep in mind. Nodes Each of the four serverboards act as a separate node in the system.
  • Page 16: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Web Site: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 17: Chapter 2 Rack Installation

    <Chapter 2: Rack Intallation> Chapter 2 Rack Installation This chapter provides instructions for preparing and mounting your chassis in a rack. Unpacking the System You should inspect the box the chassis was shipped in and note if it was damaged in any way.
  • Page 18: Warnings And Precautions

    SuperServer 6027PR-HC0(R/TR/FR) User's Manual Warnings and Precautions Rack Precautions • Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them. • In single rack installations, stabilizers should be attached to the rack. •...
  • Page 19: Rack Mounting Considerations

    <Chapter 2: Rack Intallation> Rack Mounting Considerations Ambient Operating Temperature If installed in a closed or multi-unit rack assembly, the ambient operating tempera- ture of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer’s maximum rated ambient tempera- ture (TMRA).
  • Page 20: Installing The System Into A Rack

    SuperServer 6027PR-HC0(R/TR/FR) User's Manual Installing the System into a Rack This section provides information on installing the chassis into a rack unit with the rails provided. There are a variety of rack units on the market, which may mean that the assembly procedure will differ slightly from the instructions provided. You should also refer to the installation instructions that came with the rack unit you are using.
  • Page 21: Releasing The Inner Rail

    <Chapter 2: Rack Intallation> Releasing the Inner Rail Each inner rail has a locking latch. This latch prevents the server from coming completely out of the rack when when the chassis is pulled out for servicing. To mount the rail onto the chassis, first release the inner rail from the outer rails. Releasing Inner Rail from the Outer Rails 1.
  • Page 22: Installing The Inner Rails On The Chassis

    SuperServer 6027PR-HC0(R/TR/FR) User's Manual Installing the Inner Rails on the Chassis Installing the Inner Rails 1. Identify the left and right inner rails. They are labeled. 2. Place the inner rail firmly against the side of the chassis, aligning the hooks on the side of the chassis with the holes in the inner rail.
  • Page 23: Installing The Outer Rails Onto The Rack

    <Chapter 2: Rack Intallation> Installing the Outer Rails onto the Rack Installing the Outer Rails 1. Press upward on the locking tab at the rear end of the middle rail. 2. Push the middle rail back into the outer rail. 3.
  • Page 24: Sliding The Chassis Onto The Rack Rails

    SuperServer 6027PR-HC0(R/TR/FR) User's Manual Sliding the Chassis onto the Rack Rails Warning: Mounting the system into the rack requires at least two people to support the chassis during installation. Please follow safety recommendations printed on the rails. Installing the Chassis into a Rack 1.
  • Page 25: Chapter 3 System Interface

    Chapter 3: System Interface Chapter 3 System Interface Overview The chassis includes: • Control panels on the front that include power buttons and status monitoring lights • Status lights on externally accessible hard drives • Status lights for the power supply There are four control panels located on the front, outside edges.
  • Page 26: Control Panel Buttons

    SuperServer 6027PR-HT(R/TR/FR) User's Manual Control Panel Buttons Each control panel includes two push-buttons. Power: The main power switch is used to apply or remove power from the power supply to the server. Turning off system power with this button removes the main power but maintains standby power.
  • Page 27: Overheating

    Overheat Temperature Setting Some backplanes allow the overheat temperature to be set at 45, 50, or 55 degrees by changing a jumper setting. For more information, consult the backplane user manual on the Supermicro website. Responses If the server overheats 1.
  • Page 28: Power Supply Leds

    SuperServer 6027PR-HT(R/TR/FR) User's Manual Power Supply LEDs On the rear of the power supply module, an LED displays the status. • Solid Green: When illuminated, indicates that the power supply is on. • Solid Amber: When illuminated, indicates the power supply is plugged in and turned off, or the system is off but in an abnormal state.
  • Page 29: Chapter 4 Standardized Warning Statements For Ac Systems

    Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. These warnings may also be found on our web site at http://www.supermicro.com/ about/policies/safety_information.cfm. Warning Definition Warning! This warning symbol means danger.
  • Page 30 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut.
  • Page 31 Warning Statements for AC Systems ‫جسذٌة‬ ‫اصابة‬ ً‫تتسبب ف‬ ‫حالة ٌوكي أى‬ ً‫اًك ف‬ ‫خطز‬ ًٌ‫ٌع‬ ‫هذا الزهز‬ !‫تحذٌز‬ ‫الذوائز‬ ‫بالوخاطز الٌاجوة عي‬ ‫ي على علن‬ ، ‫ك‬ ‫هعذات‬ ‫تعول على أي‬ ‫قبل أى‬ ‫الكهزبائٍة‬ ‫حىادث‬ ‫أي‬ ‫وقىع‬ ‫وٌع‬ ‫ل‬ ‫الىقائٍة‬...
  • Page 32: Installation Instructions

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Installation Instructions Warning! Read the installation instructions before connecting the system to the power source. 設置手順書 システムを電源に接続する前に、 設置手順書をお読み下さい。 警告 将此系统连接电源前,请先阅读安装说明。 警告 將系統與電源連接前,請先閱讀安裝說明。 Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación.
  • Page 33: Circuit Breaker

    Chapter 4: Warning Statements for AC Systems Circuit Breaker Warning! This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than: 250 V, 20 A. サーキッ ト ・ ブレーカー この製品は、 短絡 (過電流) 保護装置がある建物での設置を前提としています。 保護装置の定格が250 V、...
  • Page 34: Power Disconnection Warning

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL ‫في‬ ‫التي تم تثبيتها‬ ‫مه الدوائرالقصيرة‬ ‫الحمايت‬ ‫معداث‬ ‫يعتمد على‬ ‫هذا المنتج‬ ‫المبنى‬ ‫أكثر من‬ ‫ليس‬ ‫وقائي‬ ‫ال‬ ‫الجهاز‬ ‫تقييم‬ ‫أن‬ ‫تأكد من‬ 20A, 250V 경고! 이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 않도록...
  • Page 35 Chapter 4: Warning Statements for AC Systems Warnung Das System muss von allen Quellen der Energie und vom Netzanschlusskabel getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es auf den Chassisinnenraum zurückgreift, um Systemsbestandteile anzubringen oder zu entfernen. ¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico quitado de los módulos de fuente de alimentación antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema.
  • Page 36: Equipment Installation

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Equipment Installation Warning! Only trained and qualified personnel should be allowed to install, replace, or service this equipment. 機器の設置 トレーニングを受け認定された人だけがこの装置の設置、 交換、 またはサービスを許可 されています。 警告 只有经过培训且具有资格的人员才能进行此设备的安装、更换和维修。 警告 只有經過受訓且具資格人員才可安裝、更換與維修此設備。 Warnung Das Installieren, Ersetzen oder Bedienen dieser Ausrüstung sollte nur geschultem, qualifiziertem Personal gestattet werden.
  • Page 37: Restricted Area

    Chapter 4: Warning Statements for AC Systems Waarschuwing Deze apparatuur mag alleen worden geïnstalleerd, vervangen of hersteld door geschoold en gekwalificeerd personeel. Restricted Area Warning! This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security.
  • Page 38: Battery Handling

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL ‫אזור עם גישה מוגבלת‬ !‫אזהרה‬ ‫יש להתקין את היחידה באזורים שיש בהם הגבלת גישה. הגישה ניתנת בעזרת‬ .)'‫כלי אבטחה בלבד (מפתח, מנעול וכד‬ ‫محظورة‬ ‫مناطق‬ ٍ‫نتركُبها ف‬ ‫هذه انىحذة‬ ‫تخصيص‬ ‫تم‬ ،‫أداة خاصت‬ ‫من خالل استخذاو‬ ‫فقط‬...
  • Page 39 Chapter 4: Warning Statements for AC Systems Warnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp. Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers. Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant.
  • Page 40: Redundant Power Supplies

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Redundant Power Supplies Warning! This unit might have more than one power supply connection. All connections must be removed to de-energize the unit. 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります。 ユニッ トの電源を切るためには、 すべての接続を取り外さなければなりません。 警告 此部件连接的电源可能不止一个,必须将所有电源断开才能停止给该部件供电。 警告 此裝置連接的電源可能不只一個,必須切斷所有電源才能停止對該裝置的供電。 Warnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zugeführt wird, müssen alle Verbindungen entfernt werden.
  • Page 41: Backplane Voltage

    Chapter 4: Warning Statements for AC Systems ‫امداد الطاقة‬ ‫بوحدات‬ ‫عدة اتصاالت‬ ‫جهاز‬ ‫ال‬ ‫يكون لهذا‬ ‫قد‬ ‫الكهرباء‬ ‫عن‬ ‫وحدة‬ ‫ال‬ ‫لعسل‬ ‫كافة االتصاالت‬ ‫يجب إزالة‬ 경고! 이 장치에는 한 개 이상의 전원 공급 단자가 연결되어 있을 수 있습니다. 이 장치에 전원을...
  • Page 42: Comply With Local And National Electrical Codes

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Attention Lorsque le système est en fonctionnement, des tensions électriques circulent sur le fond de panier. Prendre des précautions lors de la maintenance. ‫מתח בפנל האחורי‬ !‫הרה‬ ‫אז‬ ‫קיימת סכנת מתח בפנל האחורי בזמן תפעול המערכת. יש להיזהר במהלך‬ .‫העבודה‬...
  • Page 43: Product Disposal

    Chapter 4: Warning Statements for AC Systems ¡Advertencia! La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales.Attention L'équipement doit être installé conformément aux normes électriques nationales et locales. ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ ‫הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫התקנת‬...
  • Page 44: Hot Swap Fan Warning

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Warnung Die Entsorgung dieses Produkts sollte gemäß allen Bestimmungen und Gesetzen des Landes erfolgen. ¡Advertencia! Al deshacerse por completo de este producto debe seguir todas las leyes y reglamentos nacionales. Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement.
  • Page 45 Chapter 4: Warning Statements for AC Systems 当您从机架移除风扇装置,风扇可能仍在转动。小心不要将手指、螺丝起子和其他 物品太靠近风扇 警告 當您從機架移除風扇裝置,風扇可能仍在轉動。小心不要將手指、螺絲起子和其他 物品太靠近風扇。 Warnung Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt. ¡Advertencia! Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis.
  • Page 46: Power Cable And Ac Adapter

    Electrical Appliance and Material Safety Law prohibits the use of UL or CSA -certified cables (that have UL/CSA shown on the code) for any other electrical devices than products designated by Supermicro only. 電源コードとACアダプター 製品を設置する場合、 提供または指定された接続ケーブル、 電源コードとACアダプター...
  • Page 47 Appareils électroménagers et de loi sur la sécurité Matériel interdit l'utilisation de UL ou CSA câbles certifiés qui ont UL ou CSA indiqué sur le code pour tous les autres appareils électriques que les produits désignés par Supermicro seulement.
  • Page 48 Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA gecertificeerde kabels die UL of CSA die op de code voor andere elektrische apparaten dan de producten die door Supermicro alleen. 4-20...
  • Page 49: Chapter 5 Advanced Serverboard Setup

    Chapter 5: Advanced Serverboard Setup Chapter 5 Advanced Serverboard Setup This chapter covers the steps required to install the X9DRT-P/PT/PIBF serverboard into the chassis, connect the data and power cables and install add-on cards. All serverboard jumpers and connections are also described. A layout and quick reference chart are included in this chapter for your reference.
  • Page 50: Connecting Cables

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Connecting Cables Now that the processors are installed, the next step is to connect the cables to the serverboard. Connecting Data Cables The cables used to transfer data from the peripheral devices have been carefully routed in preconfigured systems to prevent them from blocking the flow of cooling air that moves through the system from front to back.
  • Page 51: Installing The Processor And Heatsink

    • Install the processor into the CPU socket before installing the heatsink. • Refer to the Supermicro web site for updates on CPU support. Installing an LGA 2011 Processor Installing a CPU 1. There are two levers on the LGA 2011 socket.
  • Page 52 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL 3. With the second lever fully Open the load plate. retracted, gently push down on the "Open 1st" lever to loosen the load plate. Lift the load plate with your fingers to open it completely. IMPORTANT! 4.
  • Page 53 Chapter 5: Advanced Serverboard Setup Gently close the load plate. 7. With the "Close 1st" lever fully retracted, gently close the load plate. Push down and lock the lever labeled "Close 1st". 8. Make sure the locking mechanism on the "Close 1st" lever catches the lip of the load plate.
  • Page 54: Installing A Cpu Heatsink

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Installing a CPU Heatsink 1. Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the retention mechanism. 2. Screw in two diagonal screws (i.e. the #1 and the #2 screws) until just snug (do not over-tighten the screws, which may damage the CPU.) 3.
  • Page 55: Installing Memory

    Populating two slots at a time with memory modules of the same size and type will result in interleaved (128-bit) memory, which is faster than non-interleaved (64-bit) memory. Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information.
  • Page 56: Maximum Memory

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Maximum Memory The X9DRT-P/PT/PIBF serverboard supports up to 1 TB of ECC RDIMM memory in sixteen (16) DIMM slots. To Install: Insert Notch Notch module vertically and press down until it snaps into place. Front View Pay attention to the alignment notch at the bottom.
  • Page 57 1066, 1066, 1066, 1066 1066, 1333, 1333, 1333, 1333, 1333, 1600 1600, 1600, 1600 1600 1866 1866 Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm.
  • Page 58 1333 1333 QRx8 16GB 800, 1066, 800, 1066, 800, 800, 1333 1333 1333 1333 1333 1333 Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro.com/support/resources/mem.cfm. 5-10...
  • Page 59: Adding Pci Expansion Cards

    1333 1600 1600 Note: For detailed information on memory support and updates, please refer to the SMC Recommended Memory List posted on our website at http://www.supermicro. com/support/resources/mem.cfm. Other Important Notes and Restrictions • For the memory modules to work properly, please install DIMM modules of the same type, same speed and same operating frequency on the serverboard.
  • Page 60: Serverboard Details

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Serverboard Details USB0/1 FAN4 JPME1 IPMI JPME2 JLAN1 JI2C2 JI2C1 CTRL JIB1 CTRL X9DRT-P/-PT/-PIBQ/-PIBF Rev. 1.00 XDP-CPU JSD1 JBT1 I-SATA0 JBAT1 SXB1 CPU1 CLOSE 1st OPEN 1st SXB2 CPU2 CLOSE 1st OPEN 1st Figure 5-4. X9DRT-P Serverboard Layout (not drawn to scale) 5-12...
  • Page 61 Notes: 1. For the latest CPU/Memory updates, please refer to our website at http:// www.supermicro.com/products/motherboard/ for details. 2. Use only the correct type of onboard CMOS battery as specified by the manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
  • Page 62 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Connector Description InfiniBand Connector supported by the Mellano Connect-X3QDR/FDRIB chip (for X9DRT-PIBF Only) JBAT1 Onboard Battery Proprietary add-on Card for Power, FP Control & SATA Connections JIPMB1 4-pin External BMC I C Header (for an IPMI Card) JLAN1 1_ Gigabit Ethernet LAN Port supported by the Intel i350 chip (for X9DRT-P/PIBF) JLAN1...
  • Page 63: Connector Definitions

    Chapter 5: Advanced Serverboard Setup Connector Definitions JF2 Slot for Card JF2 is a proprietary slot that accepts several types of expansion card. In the 6027PR-HT(R/TR/FR) server, it is not used. Universal Serial Bus Ports Universal Serial Bus Ports (USB 0/1, USB4) Two Universal Serial Bus ports (USB Pin Definitions 0/1) are located on the I/O back panel.
  • Page 64 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL LAN1 (Ethernet Ports) A LAN (Ethernet) Port 1 is located at JLAN1 on the I/O backplane o n t h e s e r v e r b o a r d . T h i s L A N port supports Gigabit_LAN on the X9DRT-P/X9DRT-PIBF serverboards, and supports 10G_LAN on the...
  • Page 65 Chapter 5: Advanced Serverboard Setup InfiniBand Connection InfiniBand (IB) Pin Definitions The onboard InfiniBand (IB) connector Pin# Definition Pin# Definition is located on the backplane only on the X9DRT-PIBF serverboard. The Ground Transmitter Inverted Data IB switch is primarily used for high- Input performance computing.
  • Page 66 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Trusted Platform Module Header TPM/Port 80 Header (JTPM1) Pin Definitions The JTPM1 header is used to connect Pin# Definition Pin# Definition a Trusted Platform Module (TPM), LCLK available separately from a third-party vendor. A TPM is a security device that LFRAME# <(KEY)>...
  • Page 67: Jumper Settings

    Chapter 5: Advanced Serverboard Setup Jumper Settings Connector Pins Explanation of Jumpers To modify the operation of the Jumper serverboard, jumpers can be used to choose between optional settings. Jumpers create shorts between two Setting pins to change the function of the connector.
  • Page 68 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL GLAN Enable/Disable GLAN Enable (JPL1) Jumper Settings JPL1 enables or disables the LAN Jumper Setting Definition Port 1 (JPLAN1) on the serverboard. See the table on the right for jumper Pins 1-2 Enabled (default) set tings. The default set ting is Pins 2-3 Disabled Enabled.
  • Page 69 Chapter 5: Advanced Serverboard Setup Management Engine (ME) ME Recovery (JPME1) Recovery Jumper Settings Jumper Setting Definition Use Jumper JPME1 to select ME Pins 1-2 Normal (Default) Firmware Recovery mode, which will limit resource allocation for essential Pins 2-3 ME Recovery system operation only in order to maintain normal power operation and management.
  • Page 70: 5-10 Onboard Indicators

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL 5-10 Onboard Indicators LAN LEDs GLAN LED Activity Link Speed The Ethernet LAN port is located on the IO Backplane on the serverboard. Each LAN port has two LEDs. The LAN Link Indicator Yellow LED indicates activity. The LED Settings Link LED on the left side of the LAN LED Color...
  • Page 71 Chapter 5: Advanced Serverboard Setup HDD/SATA LED (LE3) HDD/SATA LED (LE3) Settings An HDD/SATA LED Indicator is located Status Definition at LE3 on the serverboard. This LED HDD/SATA Connected indicates the status of hard drive activities or SATA activities. Also see No connection the layout below for the LED locations.
  • Page 72: 5-11 Pci-Express And Serial Ata Connections

    PCI-Express 3.0 x8 Slots Two PCI-Express 3.0 x8 slots (SXB1/SXB2) are on the serverboard. SXB1 supports an Supermicro proprietary daughter card; while SXB2 is used for the proprietary add-on card. Refer to the layout below for the locations. SATA Port A Serial ATA port (I-SATA0) is located on the serverboard.
  • Page 73: 5-12 Installing Software

    Chapter 5: Advanced Serverboard Setup 5-12 Installing Software The Supermicro ftp site contains drivers and utilities for your system at ftp://ftp. supermicro.com. Some of these must be installed, such as the chipset driver. After accessing the ftp site, go into the CDR_Images directory and locate the ISO file for your serverboard.
  • Page 74: Superdoctor 5

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL SuperDoctor 5 The Supermicro SuperDoctor ® 5 is a hardware and operating system services monitoring program that functions in a command-line or web-based interface in Windows and Linux operating systems. The program monitors system health information such as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 75 Figure 5-7. SuperDoctor 5 Interface Display Screen (Remote Control) Note: The SuperDoctor 5 program and User’s Manual can be downloaded from the Supermicro web site at http://www.supermicro.com/products/nfo/sms_sd5.cfm. For Linux, we recommend that you use the SuperDoctor II application instead. 5-27...
  • Page 76: 5-13 Serverboard Battery

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL 5-13 Serverboard Battery Caution: There is a danger of explosion if the onboard battery is installed upside down, which will reverse its polarites (see Figure 5-9). This battery must be replaced only with the same or an equivalent type recommended by the manufacturer (CR2032).
  • Page 77: Chapter 6 Advanced Chassis Setup

    Chapter 6: Advanced Chassis Setup Chapter 6 Advanced Chassis Setup This chapter covers the steps required to install components and perform maintenance on the SC827HQ+-R2K02B chassis. For component installation, follow the steps in the order given to eliminate the most common problems encountered. If some steps are unnecessary, skip ahead to the step that follows.
  • Page 78: Control Panel

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Control Panel Control Panel Control Panel SATA Drives (12) Control Panel IPMI LAN Port Low-Profile PCI-E Slot Zero-slot Ethernet Ports USB Ports Infiniband Port VGA Port (6027PR-HTFR only) Figure 6-1. Front and Rear Chassis Views Control Panel The control panels for each node are located on the front of the chassis.
  • Page 79: Chassis Cover

    Chapter 6: Advanced Chassis Setup Chassis Cover Before operating the server for the first time, it is important to remove the protective film covering the top of the chassis, in order to allow for proper ventilation and cooling. Removing the Chassis Cover and Protective Film (Figure 6-2) 1.
  • Page 80: Air Shrouds

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Air Shrouds Air shrouds concentrate airflow to maximize fan efficiency. The SC827HQ+ chassis air shroud does not require screws to set up. The 6027PR-HT(R/TR/FR) requires four identical air shrouds, one in each serverboard drawer (p/n MCP-310-21702- 0B).
  • Page 81: Checking The Airflow

    Chapter 6: Advanced Chassis Setup Checking the Airflow Checking Airflow • Make sure there are no objects to obstruct airflow in and out of the server. In addition, if you are using a front bezel, make sure the bezel's filter is replaced periodically.
  • Page 82 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Changing a System Fan 1. If necessary, open the chassis while the power is running to determine which fan has failed. (Never run the server for an extended period of time with the chassis cover open.) 2.
  • Page 83 Chapter 6: Advanced Chassis Setup Figure 6-5. Replacing a System Fan in the Fan Housing...
  • Page 84: Removing And Installing The Backplane

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Removing and Installing the Backplane The SC827HQ+ chassis backplane is located behind the hard drives and in front of the front system fans. In order to change jumper settings on the backplane, it may be necessary to remove the backplane from the chassis. Removing the Backplane Removing the Backplane from the Chassis 1.
  • Page 85 Chapter 6: Advanced Chassis Setup 6. Loosen the three screws in the spring bar, located on the floor of the chassis, indicated by the arrows below (Figure 6-7). Figure 6-7. Loosening the Spring Bar Screws in the Floor of the Chassis 7.
  • Page 86: Installing The Backplane

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Installing the Backplane Installing the Backplane into the Chassis (Figure 6-9) 1. Ensure that all of the hard drive trays have been removed from the bays in the front of the chassis and that the spring bar has been loosened as directed in the previous section.
  • Page 87: Installing The Serverboard

    Chapter 6: Advanced Chassis Setup Installing the Serverboard I/O Shield The I/O shield holds the serverboard ports in place. The I/O shield does not require installation. Permanent and Optional Standoffs Standoffs prevent short circuits by securing space between the serverboard and the chassis surface.
  • Page 88: Adapter Card Replacement

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL 8. Connect the cables between the serverboard, backplane, chassis, front panel, and power supply, as needed. Also, fans may be temporarily removed to allow access to the backplane ports. 9. Replace the expansion card bracket and secure the bracket with a screw. Figure 6-10.
  • Page 89 Chapter 6: Advanced Chassis Setup Adapter Card Serverboard Drawer Five Screws Figure 6-11. Adapter Card Installation Removing the Adapter Card (Figure 6-11) 1. Disconnect the wiring connecting the adapter card to the serverboard. 2. Remove the serverboard drawer from the chassis. 3.
  • Page 90: 6-10 Expansion Slot Setup

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL 6-10 Expansion Slot Setup Each node drawer includes a slot for one low profile, half length PCI-Express expansion card and one Zero-slot expansion card. That is a total of four of each type in the system. The Zero-slot provides a spot for a proprietary form factor card, such as the AOC- PTG-i1S 10 Gigabit Ethernet adapter card.
  • Page 91: 6-11 Drive Bay Installation/Removal

    Proceed to the next step for instructions. You must use standard 1" high, SATA drives in the system. Note: Refer to Supermicro's web site for setup guidelines: <http://www.supermicro. com/support/manuals/>. The SC827HQ+ chassis contains four individual serverboards in separate node drawers (Figure 6-13).
  • Page 92 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Removing Hard Drive Trays from the Chassis (Figure 6-14) 1. Press the release button on the drive tray. This extends the drive bay handle. 2. Use the handle to pull the drive out of the chassis. Figure 6-14.
  • Page 93 Chapter 6: Advanced Chassis Setup The drives are mounted in drive carriers to simplify their installation and removal from the chassis (Figure 6-15). These carriers also help promote proper airflow for the drive bays. Dummy Drive Drive Tray Figure 6-15. Chassis Drive Tray Installing a Drive into the Hard Drive Tray 1.
  • Page 94 SATA Hard Drive Drive Tray Figure 6-17. Installing the Hard Drive Caution: Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers. For information on recommended HDDs, visit the Supermicro Web site at http://www.supermicro.com/products/nfo/files/storage/SAS-CompList.pdf 6-18...
  • Page 95: 6-12 Power Supply

    Power Supply Replacement If a power supply module must be replaced, it can be removed without powering down the system. Replacement units can be ordered directly from Supermicro. Changing the Power Supply (Figure 6-18) 1. On the rear of the chassis, unplug the AC power cord from the module.
  • Page 96 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Release Tab Figure 6-18. Changing the Power Supply 6-20...
  • Page 97: Chapter 7 Bios

    AMI BIOS setup utility. This Setup utility can be accessed by pressing <Delete> at the appropriate time during system boot. Note: For AMI UEFI BIOS Recovery, please refer to the UEFI BIOS Recovery User Guide posted at http://www.supermicro.com/support/manuals/.
  • Page 98: Starting The Setup Utility

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Starting the Setup Utility Normally, the only visible Power-On Self-Test (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS setup utility. From the main menu, you can access the other setup screens.
  • Page 99 Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.). Supermicro 6027PR-HT(R/TR/FR) Version This item displays the SMC version of the BIOS ROM used in this system.
  • Page 100: Advanced Setup Configurations

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Advanced Setup Configurations Select the Advanced tab to access the following submenu items. Boot Features Quiet Boot Use this feature to select bootup screen display between POST messages and the OEM logo. Select Disabled to display the POST messages. Select Enabled to display the OEM logo instead of the normal POST messages.
  • Page 101 Chapter 7: BIOS Wait For 'F1' If Error Select Enabled to force the system to wait until the 'F1' key is pressed when an error occurs. The options are Disabled and Enabled. Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the BIOS ROM of the host adaptors will "capture"...
  • Page 102 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL CPU Configuration  This submenu displays the following information of the CPU as detected by the BIOS. It also allows the user to configure CPU settings. Socket 1 CPU Information, Socket 2 CPU Information  This submenu displays the following information regarding the CPUs installed in Socket 1 and Socket 2.
  • Page 103 Chapter 7: BIOS Hyper-threading Select Enabled to support Intel's Hyper-threading Technology to enhance CPU performance. The options are Enabled and Disabled. Active Processor Cores Set to Enabled to use a processor's second core and above. (Please refer to Intel's website for more information.) The options are All, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, and 11. Limit CPUID Maximum Use this feature to set the maximum CPU ID value.
  • Page 104 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL DCU IP Prefetcher Select Enabled for DCU (Data Cache Unit) IP Prefetcher support, which will prefetch IP addresses to improve network connectivity and system performance. The options are Enabled and Disabled. Intel Virtualization Technology (Available when supported by the CPU) ®...
  • Page 105 Chapter 7: BIOS C1E (Available when Power Technology is set to Custom) Select Enabled to enable Enhanced C1 Power State to boost system performance. The options are Enabled and Disabled. CPU C3 Report (Available when Power Technology is set to Custom) Select Enabled to allow the BIOS to report the CPU C3 State (ACPI C2) to the operating system.
  • Page 106 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Recommended Short Duration Power Limit This item displays the short duration power settings (in watts) recommended by the manufacturer. Short Duration Power Limit This item displays the time period during which short duration power (in watts) is maintained.
  • Page 107 Chapter 7: BIOS IIO 1 PCIe Port Bifurcation Control This submenu configures the following IO PCIe Port Bifurcation Control settings for IIO 1 PCIe ports to determine how the available PCI-Express lanes to be distributed between the PCI-Exp. Root Ports. CPU1 Slot1 PCI-E Link Speed Select GEN1 to enable PCI-Exp Generation 1 support for the port specified.
  • Page 108 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL QPI (Quick Path Interconnect) Link Speed Mode Use this feature to select data transfer speed for QPI Link connections. The options are Fast and Slow. QPI Link Frequency Select Use this feature to select the desired QPI frequency. The options are Auto, 6.4 GT/s, 7.2 GT/s, and 8.0 GT/s.
  • Page 109 Chapter 7: BIOS Memory Mode When Independent is selected, all DIMMs are available to the operating system. When Mirroring is selected, the motherboard maintains two identical copies of all data in memory for data backup. When Lock Step is selected, the motherboard uses two areas of memory to run the same set of operations in parallel.
  • Page 110 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Data Scrambling Select Enabled to enable data scrambling to ensure data security and integrity. The options are Disabled and Enabled. Device Tagging Select Enabled to support device tagging. The options are Disabled and Enabled. Thermal Throttling Throttling improves reliability and reduces power consumption in the processor via automatic voltage control during processor idle states.
  • Page 111 Chapter 7: BIOS Legacy USB Support (Available when USB Functions is not Disabled) Select Enabled to support legacy USB devices. Select Auto to disable legacy support if USB devices are not present. Select Disabled to have USB devices available for EFI (Extensive Firmware Interface) applications only. The settings are Disabled, Enabled and Auto.
  • Page 112 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Port 0 ~ Port 5 Hot Plug This feature designates the port specified for hot plugging. Set this item to Enabled for hot-plugging support, which will allow the user to replace a SATA disk drive without shutting down the system. The options are Enabled and Disabled. Port 0 ~ Port 5 SATA Device Type This feature configures the selected SATA port to support either a solid state drive or hard disk drive.
  • Page 113 Chapter 7: BIOS Port 0 ~ Port 5 Spin Up Device On an edge detect from 0 to 1, set this item to allow the PCH to start a COMRESET initialization sequence to the device. The options are Enabled and Disabled.
  • Page 114 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL SCU Ports 0~3 The status of each of the SCU ports indicated above will be displayed. PCIe/PCI/PnP Configuration Launch Storage OPROM Policy This feature controls how the system executes UEFI (Unified Extensible Firmware Interface), and legacy storage OPROM. Select Legacy Only to boot the system using a legacy device installed in a PCI slot.
  • Page 115 Chapter 7: BIOS Above 4G Decoding (Available if the system supports 64-bit PCI decoding) Select Enabled to decode a PCI device that supports 64-bit in the space above 4G Address. The options are Enabled and Disabled. CPU1 Slot 1 PCI-E 3.0 x16 OPROM/ CPU1 Slot 2 PCI-E 3.0 x8 OPROM Select Enabled to enable Option ROM support to boot the computer using a device installed on the slot specified above.
  • Page 116 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Device Settings This item displays the settings of Serial Port 1 (COM). Change Settings This option specifies the base I/O port address and the Interrupt Request address of Serial Port 1 (COM). Select Disabled to prevent the serial port from accessing any system resources.
  • Page 117 Chapter 7: BIOS Serial Port Console Redirection This submenu allows the user to configure the following Console Redirection settings for this Port. Console Redirection Select Enabled to use the SOL Port for Console Redirection. The options are Enabled and Disabled. This submenu allows the user to configure the following Console Redirection settings for the SOL Port specified by the user.
  • Page 118 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Parity A parity bit can be sent along with regular data bits to detect data transmission errors. Select Even if the parity bit is set to 0, and the number of 1's in data bits is even. Select Odd if the parity bit is set to 0, and the number of 1's in data bits is odd.
  • Page 119 Chapter 7: BIOS Redirection After BIOS Post Use this feature to enable or disable legacy console redirection after BIOS POST. When set to Bootloader, legacy console redirection is disabled before booting the OS. When set to Always Enable, legacy console redirection remains enabled when booting the OS.
  • Page 120 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Flow Control This feature allows the user to set the flow control for Console Redirection to prevent data loss caused by buffer overflow. Send a "Stop" signal to stop sending data when the receiving buffer is full. Send a "Start" signal to start sending data when the receiving buffer is empty.
  • Page 121 Chapter 7: BIOS Trusted Computing (Available when a TPM device is detected by the BIOS) Configuration TPM Support Select Enabled on this item and enable the TPM jumper on the motherboard to enable TPM support to improve data integrity and network security. The options are Enabled and Disabled.
  • Page 122 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Intel TXT (LT-SX) Configuration Intel TXT (LT-SX) Hardware Support This feature indicates if the following hardware components support the Intel Trusted Execution Technology. CPU: TXT (Trusted Execution Technology) Feature Chipset: TXT (Trusted Execution Technology) Feature Intel TXT (LT-SX) Configuration This feature displays the following TXT configuration setting.
  • Page 123 Chapter 7: BIOS • Commit Changes and Exit • Discard Changes and Exit • Change Attempt Order • Commit Changes and Exit • Discard Changes and Exit Intel® I350 Gigabit Network Connections These items display the following information on the Intel I350 LAN connections. NIC Configuration Link Speed Use this feature to change the link speed and duplex for the current port.
  • Page 124: Event Logs

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Event Logs Select the Event Logs tab to access the following submenu items. Change SMBIOS Event Log Settings  This feature allows the user to configure SMBIOS Event settings. Enabling/Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS (System Management BIOS) Event Logging during system boot.
  • Page 125 Chapter 7: BIOS PCI Error Logging Support Select Enabled to support error event logging for PCI slots. The options are Enabled and Disabled. Erasing Settings Erase Event Log Select Enabled to erase the SMBIOS (System Management BIOS) Event Log, which is completed before a event logging is initialized upon system reboot.
  • Page 126: Ipmi

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL IPMI Select the IPMI (Intelligent Platform Management Interface) tab to access the following submenu items. IPMI Firmware Revision, IPMI Status These items indicates your system IPMI firmware revision number and status. System Event Log  SEL Components Select Enabled for all system event logging at bootup.
  • Page 127 Chapter 7: BIOS When SEL is Full This feature allows the user to decide what the BIOS should do when the system event log is full. Select Erase Immediately to erase all events in the log when the system event log is full. The options are Do Nothing and Erase Immediately. Custom EFI Logging Options Log EFI Status Codes Select Enabled to log EFI (Extensible Firmware Interface) Status Codes, Error...
  • Page 128: Boot

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Station IP Address This item displays the Station IP address for this computer. This should be in decimal and in dotted quad form (i.e., 192.168.10.253). Subnet Mask This item displays the sub-network that this computer belongs to. The value of each three-digit number separated by dots should not exceed 255.
  • Page 129 Chapter 7: BIOS Set Boot Priority This option prioritizes the order of bootable devices that the system to boot from. Press <ENTER> on each entry from top to bottom to select devices. • 1st Boot Device • 2nd Boot Device •...
  • Page 130: Security

    SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL  Delete Driver Option This feature allows the user to delete a previously defined boot device from which the systems boots during startup. The settings are [any pre defined boot device] Security This menu allows the user to configure the following security settings for the system.
  • Page 131: Save & Exit

    Chapter 7: BIOS Save & Exit This submenu allows the user to configure the Save and Exit settings for the system. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system configuration, and reboot the computer. Select Discard Changes and Exit, and press <Enter>.
  • Page 132 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Save Options Save Changes Select this option and press <Enter> to save all changes you've done so far and return to the AMI BIOS utility Program. When the dialog box appears, asking you if you want to save configuration, select Yes to save the changes, or select No to return to the BIOS without making changes.
  • Page 133: Appendix A Bios Error Beep Codes

    Appendix A: BIOS Error Beep Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the system is powered on, errors may occur. Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
  • Page 134 SUPERSERVER 6027PR-HT(R/TR/FR) USER'S MANUAL Notes...
  • Page 135: Appendix B System Specifications

    1600/1333/1066/800 MHz registered ECC SDRAM in 1 GB, 2 GB, 4 GB, 8 GB, 16 GB or 32 GB size sizes of 1.5V or 1.35V voltages. Note: Refer to Section 5-6 for details on installation. Note: Check the Supermicro website (www.supermicro.com) for the latest memory support information. SATA Drive Bays The SuperServer 6027PR-HT(R/TR/FR) contains twelve hot-swap drive bays to house twelve standard SATA drives.
  • Page 136 SUPERSERVER 6027PR-HT(R/TR/FR) User's Manual Chassis SC827HQ+-R2K02B (2U rackmount) Dimensions: (WxHxD) 17.25 x 3.47 x 30.25 in. (438 x 88 x 768 mm) Weight Gross (Bare Bone): 90 lbs. (40.9 kg.) System Cooling The system has four (4) 8-cm PWM system cooling fans System Input Requirements AC Input Voltage: 85-264V AC auto-range Rated Input Current: 15 - 5A...
  • Page 137 Appendix B: System Specifications Notes...
  • Page 138 SUPERSERVER 6027PR-HT(R/TR/FR) User's Manual (continued from front) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, aircraft/emergency communication devices or other critical systems whose failure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage.

Table of Contents