The manufacturer’s software and documentation are copyrighted with all rights reserved. It is illegal to make copies for another person. Specifications subject to change without notice. info@Raytek-Direct.com 1.888.475.5235...
The instrument should not be used for medical diagnosis. Replacement Parts and Accessories Use only original parts and accessories approved by the manufacturer. The use of other products can compromise the operation safety and functionality of the instrument. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 7
This product meets requirements for industrial (Class A) electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and is not to be used in homes. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 8
Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at their own expense. See figure below for the safety markings. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 9
Do not put battery cells and battery packs near heat or fire. Do not put in sunlight. • To avoid damage to the product or the equipment under test, protect them from: EMF (electro-magnetic fields) from arc welders, induction heaters, etc. • • Static electricity 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 10
For the short wavelength units (e.g., 1.0 µm and 1.6 µm) — avoid taking temperature • measurements in bright sunlight. High levels of ambient light may produce apparently valid high-temperature readings when no target is in the thermometer’s field-of-view. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
• Warning system to prevent high temperature damage • Bluetooth wireless technology for communication with a mobile device ® • Documenting personal computer (PC) software Bluetooth is a registered trademark owned by Bluetooth SIG, Inc. ® 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
90% energy in minimum and distance 4000 mm (157 in.) Calibration geometry at ambient temperature 23°C ±2°C (73°F ±4°F), emissivity = 1.0 Calibration geometry at ambient temperature 23°C ±2°C (73°F ±4°F), emissivity = 1.0 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
≤ 12 000 m (40,000 ft.) Size Standard 218 x 172 x 74 mm (8.6 x 6.8 x 2.9 in.) with scope 218 x 222 x 74 mm (8.6 x 8.7 x 2.9 in.) 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
• Mini USB to DC jack converter for charging battery separately 1.5 m (4.9 ft.) computer cable with USB to Mini USB • • Operator’s manual (printed format) Laser: off, Bluetooth: off 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
This measuring error can be reduced to a minimum if particular care is taken during installation, and the sensing head is shielded from these reflecting radiation sources. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
USB interface. Internal memory circuits store temperature data for later recall, and a data-logging feature allows users to store and multiple temperature, emissivity, and alarm readings (valuable for comparative analysis). The following figure shows the features of the portable infrared thermometer. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Charts, page 14. During measurements, please make sure that the target is larger than the instrument’s measurement spot size at that distance. The smaller the target, the closer user should be to it. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
An indicator on the battery will show a “charging” red light and “charge complete” green light. The instrument can be powered when connecting the USB cable to the PC but there is no charging since many USB ports have not enough power capability! 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
The data will be saved in a curve format and the user can review the value of each test point with PC software. Press <View> to review the trend picture. User can press up and 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
The instrument can display two languages, English and Simplified Chinese. To change the displayed language, see section 5.10.10.6 Language, page 28. 5.10.1 Overview There are many settings that can be changed with the menu. The following figure shows the LCD and menu interface. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 22
In addition to the soft keys, there are also the <Save> and <Return> soft keys below the LCD display. Selecting the <Menu> soft key advances the menu to the next level. The following table shows the top- level description of the menu. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
The maximum number of test points is 300. These test points are arranged in three levels, and the maximum allowed for the second level is 50. The first and second levels could be represented by three 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 24
15. Press <Next> to continue to the second level menu, and upload to the instrument. Here, the user can also continue to the next screen using the arrow keys. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
User also can choose the <Manual> mode to set the upper and lower limits and the time span. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
5.10.8 Lock – Trigger Button The instrument’s trigger can be locked to take temperature readings continuously without pressing the trigger button all the time. To lock the trigger button: 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Use the up and down soft keys to change the selected parameter. Push the <Next> soft key and the arrow soft keys to select the month, date, or year parameters. Use the up and down soft keys to change the selected parameter. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Use the down arrow soft key to move the indicator to <Language>. Push the <Enter> soft key. Push the <F1> soft key to complete the language selection or push the <Back> soft key to return to the Setup menu. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Push the <Log> soft key and the select the temperature record of interest (Profile, Basic, or Trend) to review it. Additionally, pushing the <Delete> soft key allows you to remove an individual or all sets of the temperature record. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
7.0 and above. After activating Bluetooth on the instrument, the user can find it on the iPhone. Use the “Raytek 3i Plus” App, which can be downloaded from the App Store (please search by its name). To monitor real-time measurement in a relative faraway place, download the Basic test data and Profile test data, take photos and send via e-mail.
Mini USB port adaptor with multi-country power plug (100 – 240 VAC, 50/60 Hz), including • SAA, EU, UK, US and CCC (XXXR3IPLUSPS) Mini USB-to-DC jack converter for charging battery separately (XXXR3IPLUSPSCON) • Computer cable with USB-to-Mini USB, 1.5 m (4.9 ft) (XXXR3IPLUSUSBCB) • 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
More advanced users might spend time to define and create a profile through the PC to optimize their measurement. Figure 6: Main Screen 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
From the CD, launch the executing file to install the software on a computer. Follow the installation wizard’s instructions on the screen. While installing the software, the USB driver for the instrument is installed Automatically! 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Step 1: Connect the instrument to the PC via USB Step 2: Open the <File> menu Figure 7: Open File Step 3: Choose appropriate COM Port with Raynger 3i Plus Device and click <Connect> Figure 8: COM Port Selection 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 35
Windows Software A simultaneous communication via USB and Bluetooth is not allowed! 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
The user can also change these settings through the PC interface and upload to the instrument. Click on the <Setting> button to launch the corresponding dialog box. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
The user can replay the file recorded in real-time mode, search it according to date, and open the file to review the trend change. The user can also export the saved curve into the .csv file format. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 38
Windows Software Figure 11: Replay Window 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Figure 12: Basic Window There is a check box with each table row, so the user can choose the data to edit or export to a test report with *. csv format. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
There are two locations to store the profile: <Local> and <Device>. The user can upload, edit, and create the profile under the <Local> place, and download the device profile and device test data in <Device> place. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
For example: User named the first level “qwe,” the second level “asd,” and the test point is 20 pcs. After these profiles were created, the user can upload these profiles to the instrument. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
<Import to Local> to perform editing both the profile structure and the profile test data in <Local> place. User can also delete the profile structure and profile test data in this place. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 43
Windows Software Figure 17: Device Profile The user can also download the test data with the <Export> function into a csv format. Figure 18: Export Data to the PC 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 44
FALSE 765.8 C 2014/4/10 8:39 0.25 FALSE 100% FALSE 25.0C 2999.0C FALSE 699.0C FALSE 766.1 C 2014/5/10 8:29 0.25 FALSE 100% FALSE 25.0C 2999.0C FALSE 699.0C FALSE Figure 19: Exemplary Historical Record 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Mobile App 8 Mobile App The “Raytek 3i Plus” mobile app is a computer program designed to run on smartphones, tablet computers and other mobile devices. The app requires the support of the iOS mobile operating system 7.0 or higher.
Notes: The download data won’t be stored in iPhone, so if user left this page and enter again, the APP will download the test data again automatically. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
By clicking on the desired data set, the temperature and the relative settings of the reading will be shown, see right figure below. Figure 24: Basic Log Clicking on the e-mail icon in the upper right corner enables details to be emailed. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Figure 26: Basic Log – Multiple Data Sets 8.2.2 Data Review by Time By clicking on the time input box in the upper left corner, a dialog box opens to select the starting time/data for the recorded data sets. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 49
Figure 28: Basic Log – Data Sets at the desired End Time By clicking on the <Finding> icon, the selected items will be displayed as follows: 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
By selecting the <Profile Test Data> icon, the user can download the Profile Test data from the unit. Clicking on each item provides the detail data for that group. Note: To ensure the download process more smooth, please do not use the unit perform testing during data download period. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 51
By clicking on the e-mail icon in the upper right corner the selected test data can be sent. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 52
Mobile App Figure 33: Profile Test Data with Photos Attached 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Reinstall the latest PC software with PC Via Cable USB interface damage Contact Service Wrong iPhone software Reinstall the latest iPhone App Unable to Communicate with iPhone Via Bluetooth Bluetooth damage Contact Service Table 5: Troubleshooting 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
To avoid damaging the instrument, do NOT submerge it in water. Do not use abrasive Cleaners will damage the case! 9.4 Laser Fault If the laser (laser models only) does not operate properly, call the supplier of the instrument. DO NOT open the instrument’s main housing. 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
For exchanging the battery, follow the steps given below. 1. Unscrew the battery door. 2. Remove the battery door bolt. 3. Slide the battery along the lead rail. Figure 34: Removing the Battery 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Page 58
Hold instrument perpendicular to surface whenever emissivity is less than 0.9. In all cases, do not exceed angles more than 30 degrees from incidence. For 1M and 2M models, avoid measurements in high ambient light conditions. • 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...
Electromagnetic Compatibility and Radio Spectrum Matters (ERM); Wideband Transmission System; Data Transmission Equipment Operating in the 2.4 GHz ISM Band and Using Wide Band Modulation Techniques; Harmonized EN Covering Essential Requirements under Article 3.2 of the R&TTE Directive 3i Plus info@Raytek-Direct.com 1.888.475.5235 Rev. A1 Jan 2015...