Epson DFX-9000 Service Manual page 149

Serial impact dot matrix printer
Hide thumbs Also See for DFX-9000:
Table of Contents

Advertisement

Epson DFX 9000
4.2.3.4 AC SW ASY, INLET ASY
Disconnect the power cable and wait at least 5 minutes for
W A R N I N G
capacitors to drain before disassembling the POWER
UNIT. If you touch the POWER UNIT with the power
supplied, you may receive an electric shock.
1. Remove the
PR MECHA ASY (p. 149)
2. Release the AC SW ASY cables from the three cable routing tabs
and two cable clamps that secure the AC SW ASY cable to the
LOWER UNIT.
3. Disconnect the AC SW ASY connector (ACIN: 3 pins) from the
POWER UNIT.
4. Disconnect the AC SW ASY cables (blue and brown) from the
INLET ASY.
Connect the AC SW ASY cable to the INLET ASY
correctly, as shown in
Upper pin: the blue cable.
Lower pin: the brown cable.
Disassembly and Assembly
Figure
4-15.
AC SW ASY, INLET ASY
INLET ASY
7)
3)
Cable
clamps
2)-2
Tabs
2)-1
AC SW ASY
Figure 4-15. AC SW ASY Removal (1)
Revision B
Blue cable
4)
Brown cable
INLET ASY
Connector
(ACIN)
POWER UNIT
142