Checkout Procedure; About The Checkout Procedure - IBM 7940 Problem Determination And Service Manual

Ibm system x3455 type 7940 and 7941
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7940 and 7941 servers," on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
01298200
Processor speed mismatch.
19990301
Hard disk sector error.
19990305
An operating system was not found.

Checkout procedure

The checkout procedure is the sequence of tasks that you must follow to diagnose
a problem in the server.

About the checkout procedure

Before performing the checkout procedure for diagnosing hardware problems,
review the following information:
v Read the safety information that begins on page vii.
v The diagnostic programs provide the primary methods of testing the major
v When you run the diagnostic programs, a single problem might cause more than
components of the server, such as the system board, Ethernet controller,
keyboard, mouse (pointing device), serial ports, and hard disk drives. You can
also use them to test some external devices. If you are not sure whether a
problem is caused by the hardware or by the software, you can use the
diagnostic programs to confirm that the hardware is working correctly.
one error message. When this happens, correct the cause of the first error
message. The other error messages usually will not occur the next time you run
the diagnostic programs.
Exception: If there are multiple error codes or error LEDs that indicate a
microprocessor error, the error might be in the microprocessor or in the
Action
Make sure that all microprocessors have the same
number of cores, cache size and type, clock speed,
and clock frequencies (see "Using the
Configuration/Setup Utility program" on page 15).
1. Reseat the hard disk drive.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive
b. (Trained service technician only) System
board
1. Make sure that a bootable operating system is
installed.
2. Run the hard disk drive diagnostic test.
3. Reseat the hard disk drive.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Hard disk drive
b. (Trained service technician only) System
board
83