Diagnostic Error Codes - IBM 7940 Problem Determination And Service Manual

Ibm system x3455 type 7940 and 7941
Table of Contents

Advertisement

Diagnostic error codes

The following table describes the error codes that the diagnostic programs might
generate and suggested actions to correct the detected problems.
If the diagnostic programs generate error codes that are not listed in the table,
make sure that the latest level of BIOS code is installed (see "Updating the
firmware" on page 15).
In the error codes, x can be any numeral or letter. However, if the three-digit
number in the central position of the code is 000, 195, or 197, do not replace a
CRU or FRU. When these numbers are in the central position of the code, they
have the following meanings:
000
195
197
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7940 and 7941 servers," on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
000-197-000
Test aborted
000-198-000
001-250-00n
ECC test logic failed. See PC Doctor logs.
Note: n = Failing CPU. (1-4)
001-xxx-000
Failed core test.
001-xxx-001
Failed core test.
005-xxx-000
Failed video test.
011-xxx-000
Failed COM1 serial port test.
015-xxx-001
USB interface not found, board damaged.
The server passed the test. Do not replace a CRU or FRU.
The Esc key was pressed to end the test. Do not replace a CRU or FRU.
This is a warning error, but it does not indicate a hardware failure; do not
replace a CRU or FRU. Take the action that is indicated in the Action
column but do not replace a CRU or a FRU. See the description of
Warning in "Diagnostic text messages" on page 102 for more information.
Action
1. Check the test log for messages that indicate the
cause of the error, and take the indicated action.
2. Reinstall and, if necessary, update the BIOS code
on the server; then, rerun the test (see "Updating
the firmware" on page 15).
1. Restart the server.
2. Run the diagnostic test again.
3. (Trained service technician only) Replace the
failing microprocessor.
4. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
(Trained service technician only) Replace the system
board.
1. Check the loopback plug that is connected to the
serial port (if installed).
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
103
Chapter 5. Diagnostics