v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Type 7940 and 7941 servers," on page 19 to determine which components
are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
015-xxx-198
USB device connected during test.
020-xxx-000
Failed PCI Express interface test.
089-xxx-00n
Failed microprocessor test.
n = number of failing microprocessor
201-198-xxx
Memory test aborted.
201-199-xxx
Unexpected error. Test aborted.
201-xxx-PBD
Multiple DIMM failure.
v P = CPU Number [1 - 4].
v B = Failing Bank/Pair number.
v D = Failing DIMM number within failing
CPU # P.
v D = 9 = Both DIMMs in the failing
bank/pair of DIMMs.
206-xxx-000
Failed diskette drive test.
104
IBM System x3455 Type 7940 and 7941: Problem Determination and Service Guide
Action
1. Disconnect all USB devices and run the test
again.
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board.
1. Reinstall and, if necessary, update the BIOS code
on the server (see "Updating the firmware" on
page 15); then, run the test again.
2. Trained service technician only:
a. Reseat microprocessor n.
b. Replace microprocessor n.
c. Replace the system board.
1. Restart the server.
2. Run the diagnostic test again.
3. See the error log for additional information.
1. Restart the server.
2. Run the diagnostic test again.
3. Refer to the error log for additional information.
1. Reseat the failing DIMM(s); then, run the memory
diagnostic test again.
2. Replace the failing DIMM(s); then, run the
memory diagnostic test again.
3. (Trained service technician only) Replace the
system board.
1. Rerun the test using another diskette.
2. Reseat the diskette drive cable in the connector.
3. If you are using an external USB hub, disconnect
the diskette drive from the hub and connect it
directly to the server.
4. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Diskette drive.
b. (Trained service technician only) System
board